• Title/Summary/Keyword: IR radiation

Search Result 361, Processing Time 0.032 seconds

Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer (퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정)

  • Jeon, Sang-Ho;Yoo, Nam-Joon;Jo, Jae-Heung;Park, Chul-Woung;Park, Seung-Nam;Lee, Geun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.400-407
    • /
    • 2008
  • An Instrument to measure normal spectral emissivity is built using a Fourier Transform-Infrared (FT-IR) spectrometer. The instrument is composed of four main parts, reference blackbody, sample furnace, optics system, and FT-IR spectrometer. Measurement ranges of temperature and wavelength are $200^{\circ}C{\sim}500^{\circ}C$ and $3.5{\mu}m{\sim}20{\mu}m$, respectively. Measured emissivity of the reference blackbody is greater than 0.9993 with combined relative uncertainty less than 0.69%, which can be considered an ideal blackbody. We studied the emissivity of opaque alumina, graphite, anodized aluminum, and steel (IMS 200). It is shown that emissivity increases with the roughness of the steel (IMS 200) surface.

Effect of Rutin on Adhesion Molecules Expression and NO Production Induced by $\gamma$-irradiation in Human Endothelial cells

  • Son, Eun-Wha;Lee, Kang-Ro;Rhee, Dong-Kwon;Pyo, Suh-Kneung
    • Biomolecules & Therapeutics
    • /
    • v.9 no.3
    • /
    • pp.156-161
    • /
    • 2001
  • Inflammation is a frequent radiation-induced following therapeutic irradiation. Treatment of human umbilical endothelial cells (HUVEC) with ${\gamma}$-irradiation (${\gamma}$IR) induces the expression of adhesion proteins such as intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), and E-selectin. Since the upregulation of these proteins on endothelial cell surface has been known to be associated with inflammation, interfering with the expression of adhesion molecules is an important therapeutic target. In the present study, we demonstrate that bioflavonoid rutin inhibits ${\gamma}$IR induced expression of ICAM-1, VCAM-1, and E-selectin on HUVEC in a dose- and time dependent manner. Rutin also inhibited ${\gamma}$IR induced production of NO. These data suggest that rutin has therapeutic potential for the treatment of various inflammatory disorder associated with an increase of endothelial leukocyte adhesion molecules.

  • PDF

Smoothness of the Zodiacal Light and Emission from the AKARI North Ecliptic Pole Monito rObservations

  • Pyo, Jeong-Hyun;Matsumoto, Toshio;Tange, Tsutomu;Jeong, Woong-Seob;Matsuhara, Hideo;Matsuura, Shuji;Wada, Takehiko;Seo, Hyun-Jong;Hong, Seung-Soo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.52.1-52.1
    • /
    • 2010
  • The Japanese infrared (IR) space mission AKARI monitored the brightness in the fields very close to the north ecliptic pole (NEP) with nine wavebands in Infrared Camera (IRC), which cover the wavelength range from 2 to $24{\mu}m$. We reduced the NEP monitor observations and examined the smoothness of the sky background brightness. Our analysis shows that the background brightness is smooth over a frame of about $10'\times10'$ within about 0.1% deviation in mid-IR. Because the zodiacal light (ZL) and emission (ZE) dominate the diffuse sky brightness in the near- and mid-IR wavelengths, the background brightness varies with season through a year. We tried sinusoidal fittings to the observed NEP background brightness. The fitting analysis shows that the sine function is successful in describing the seasonal variation of the ZL and ZE within 2% deviations from the observed brightness, especially for the 15, 18, and $24{\mu}m$ bands, within 0.3%. These results will provide limits and caveats for the studies of the cosmic infrared background radiation.

  • PDF

IR Signal Analysis and Band Selection for Two-color Seeker (Two-color 탐색기를 위한 적외선 신호 분석 및 대역 선정)

  • 오정수;서동선;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.112-119
    • /
    • 2000
  • A two-color infrared (IR) seeker employs two detection-bands for efficient target tracking under countermeasures and background noises. This paper describes a study on the detection-band selections for the two-color seeker. To select the detection-bands, we analysis infrared radiation characteristics of a target, a flare, and background noises and then other characteristics closely related with the received power, such as the atmospheric transmission, acquisition range, background noise effect, and signal-to-noises. The analysis shows that the pertinent bands of two-color IR seeker are 3 um~5 um for target detection and 1.5 um~l.7 um for counter-countermeasures. The results of our study will play a significant role in the further study of two-color seekers.

  • PDF

Molecular identification of dye degrading bacterial isolates and FT-IR analysis of degraded products

  • Khan, Shellina;Joshi, Navneet
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.561-570
    • /
    • 2020
  • In the present study, dye decolorizing bacteria were isolated from water and soil samples, collected from textile industries in Jodhpur province, India. Two bacterial species namely, Bacillus pumilis and Paenibacillus thiaminolyticus were screened and identified based on biochemical characterization. The degradation efficiency of these two microorganisms was compared through optimization of pH, incubation time, initial dye concentration and inoculum size. B. pumilis and P. thiominolyticus were able to degrade 61% and 67% Red HE3B, 81% and 75% Orange F2R, 49.7% and 44.2% Yellow ME4GL and 61.6% and 59.5% Blue RC CT dyes of 800mg/l concentration respectively. The optimum pH and time were found to be 8 within 24 hours. The FT-IR analysis confirmed that microorganisms were able to degrade toxic azo dyes into a non-toxic product as proved through structural modifications to analyze chemical functions in materials by detecting the vibrations that characterize chemical bonds. It is based on the absorption of infrared radiation by the microbial product. Therefore, Bacillus pumilis and Paenibacillus thiaminolyticus are a promising tool for decolorization of dyes due to its potential to effectively decolorize higher azo dye concentrations (10-800 mg/L) and can be exploited for bioremediation.

Allicin Reduces Adhesion Molecules and NO Production Induced by γ-irradiation in Human Endothelial Cells

  • Son, Eun-Wha;Cho, Chul-Koo;Pyo, Suhkneung
    • IMMUNE NETWORK
    • /
    • v.2 no.1
    • /
    • pp.6-11
    • /
    • 2002
  • Background: Inflammation is a frequent reaction following therapeutic irradiation. Since the upregulation of adhesion molecules on endothelial cell surface is known to be associated with inflammation, the expression of adhesion molecules is an important therapeutic target. Methods: Treatment of human umbilical endothelial cells (HUVECs) with ${\gamma}$-irradiation (${\gamma}IR$) induces the expression of adhesion proteins such as intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), and E-selectin. Changes in the expression of these proteins on ${\gamma}$-irradiated HUVECs which had been treated previously with allicin were measured by ELISA. Results: In the present study, we demonstrate that allicin inhibits the ${\gamma}IR$ induced expression of ICAM-1, VCAM-1, and E-selectin on HUVEC in a dose-dependent manner. Allicin was also found to inhibit the ${\gamma}IR$ induced production of nitric oxide (NO). Conclusion: These data suggest that allicin has a therapeutic potential for the treatment of various inflammatory disorders associated with increase numbers of endothelial leukocyte adhesion molecules.

ROIC Design of HgCdTe FPA for MWIR detection and Implementation of Thermal Image (중적외선 감지용 초점면 배열 HgCdTe의 신호 취득 회로 설계 및 열영상 구현)

  • Kim, Byeong-Hyeok;Lee, Hui-Cheol;Kim, Chung-Gi
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.3
    • /
    • pp.63-71
    • /
    • 2000
  • Infrared (IR) detector chip, which detects the IR radiation from all of the objects and converts to image signal, is usually fabricated using hybrid bonding technology with detector away and readout integrated circuit (ROIC). In this study, we designed the readout circuit and simulated its operations. Fabricating readout circuit chips, we measured operation results satisfying its design requirements in 6V supply voltage. After we mount the IR detector chip in the manufactured thermal image system, thermal images were implemented. The obtained thermal images for high and room temperature target objects are sufficiently recognizable. Using the low noise thermal Image system, we expect to obtain thermal images with higher temperature resolution.

  • PDF

Dose Verification Study of Brachytherapy Plans Using Monte Carlo Methods and CT Images (CT 영상 및 몬테칼로 계산에 기반한 근접 방사선치료계획의 선량분포 평가 방법 연구)

  • Cheong, Kwang-Ho;Lee, Me-Yeon;Kang, Sei-Kwon;Bae, Hoon-Sik;Park, So-Ah;Kim, Kyoung-Joo;Hwang, Tae-Jin;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • Most brachytherapy treatment planning systems employ a dosimetry formalism based on the AAPM TG-43 report which does not appropriately consider tissue heterogeneity. In this study we aimed to set up a simple Monte Carlo-based intracavitary high-dose-rate brachytherapy (IC-HDRB) plan verification platform, focusing particularly on the robustness of the direct Monte Carlo dose calculation using material and density information derived from CT images. CT images of slab phantoms and a uterine cervical cancer patient were used for brachytherapy plans based on the Plato (Nucletron, Netherlands) brachytherapy planning system. Monte Carlo simulations were implemented using the parameters from the Plato system and compared with the EBT film dosimetry and conventional dose computations. EGSnrc based DOSXYZnrc code was used for Monte Carlo simulations. Each $^{192}Ir$ source of the afterloader was approximately modeled as a parallel-piped shape inside the converted CT data set whose voxel size was $2{\times}2{\times}2\;mm^3$. Bracytherapy dose calculations based on the TG-43 showed good agreement with the Monte Carlo results in a homogeneous media whose density was close to water, but there were significant errors in high-density materials. For a patient case, A and B point dose differences were less than 3%, while the mean dose discrepancy was as much as 5%. Conventional dose computation methods might underdose the targets by not accounting for the effects of high-density materials. The proposed platform was shown to be feasible and to have good dose calculation accuracy. One should be careful when confirming the plan using a conventional brachytherapy dose computation method, and moreover, an independent dose verification system as developed in this study might be helpful.

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.

ASTROPHYSICS OF DUSTY STELLAR WINDS FROM AGB STARS

  • Suh, Kyung-Won
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.6
    • /
    • pp.219-233
    • /
    • 2014
  • The main site of dust formation is believed to be the cool envelopes around AGB stars. Nearly all AGB stars can be identified as long-period variables (LPVs) with large amplitude pulsation. Shock waves produce by the strong pulsation and radiation pressure on newly formed dust grains drive dusty stellar winds with high mass-loss rates. IR observations of AGB stars identify various dust species in different physical conditions. Radio observations of gas phase materials are helpful to understand the overall properties of the stellar winds. In this paper, we review (i) classification of AGB stars; (ii) IR two-color diagrams of AGB stars; (iii) pulsation of AGB stars; (iv) dust around AGB stars including dusty stellar winds; (v) dust envelopes around AGB stars; (vi) mass-loss and evolution of AGB stars; and (vii) contribution of AGB dust to galactic environments. We discuss various observational evidences and their theoretical interpretations.