• Title/Summary/Keyword: IR laser

Search Result 200, Processing Time 0.025 seconds

Characteristics of Visible Laser Diode and Its Injection-Locking (가시광 다이오드 레이저의 스펙트럼 및 주입-잠금 특성분석)

  • 남병호;박기수;권진혁
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.278-285
    • /
    • 1994
  • We investigated the spectral characteristics for temperature and driving current change in visible laser diode. As a result of spectrum analysis, the ratio of frequency change for temperature and driving current change were about $33 GHz/^{\circ}C$, 6.6 GHz/mA in the region which was not mode hopping range. Compared to the sharp mode hopping in the near IR single mode AlGaAs lasers, the visible laser diode showed relatively broad multimode operation in the mode hopping region. We performed the experiment of injection-locking characteristics analysis for visible laser diode. Locking half bandwidth(LHBW) was measured 0~5.0 GHz for $0~25\muW$ input power and it was dependent on the input power. Also, LHBW for polarization angle was dependent on the difference of polarization angle between master laser and slave laser. The phase change of injection-locked output beam of the slave laser diode as a function of the drive current was measured in the interferometer which was composed of master laser and slave laser. The ratio of phase change with the slope of 5.0~1.3 rad/mA was obtained within injection-locking range for the change of $2~25\muW$ input power. power.

  • PDF

Hydrophilic Graphite Nanoparticles Synthesized by Liquid Phase Pulsed Laser Ablation and Their Carbon-composite Sensor Application (액상 펄스 레이저 어블레이션에 의한 친수성 그라파이트 나노입자의 제조 및 센서 응용)

  • Choi, Moonyoul;Kim, Yong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.236-241
    • /
    • 2012
  • It is widely recognized that it is hard to prepare hydrophilic graphite nanoparticles because of their high crystallinity and inert characteristics. In this study, we successfully synthesized the hydrophilic graphite nanoparticles by using liquid phase pulsed laser ablation method which has been actively employed for the thin film deposition up to now. The obtained hydrophilic graphite showed an ultra-high dispersion stability in water, because the hydrophilic functional groups like carboxyl and carbonyl group was simultaneously introduced onto the graphite surface with the nanoparticle formation, as confirmed by FT-IR and zeta potential measurements. Finally, a markedly enhanced gas sensing ability for acetone was shown in comparison with the conventional carbon black for the carbon polymer composite sensor with polyethyleneglycol (PEG).

Femtosecond Mid-IR Cr:ZnS Laser with Transmitting Graphene-ZnSe Saturable Absorber

  • Won Bae Cho;Ji Eun Bae;Seong Cheol Lee;Nosoung Myoung;Fabian Rotermund
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.738-744
    • /
    • 2023
  • Graphene-based saturable absorbers (SAs) are widely used as laser mode-lockers at various laser oscillators. In particular, transmission-type graphene-SAs with ultrabroad spectral coverage are typically manufactured on transparent substrates with low nonlinearity to minimize the effects on the oscillators. Here, we developed two types of transmitting graphene SAs based on CaF2 and ZnSe. Using the graphene-SA based on CaF2, a passively mode-locked mid-infrared Cr:ZnS laser delivers relatively long 540 fs pulses with a maximum output power of up to 760 mW. In the negative net cavity dispersion regime, the pulse width was not reduced further by inhomogeneous group delay dispersion (GDD) compensation. In the same laser cavity, we replaced only the graphene-SA based on CaF2 with the SA based on ZnSe. Due to the additional self-phase modulation effect induced by the ZnSe substrate with high nonlinearity, the stably mode-locked Cr:ZnS laser produced Fourier transform-limited ~130 fs near 2,340 nm. In the stable single-pulse operation regime, average output powers up to 635 mW at 234 MHz repetition rates were achieved. To our knowledge, this is the first attempt to achieve shorter pulse widths from a polycrystalline Cr:ZnS laser by utilizing the graphene deposited on the substrate with high nonlinearity.

Visible-light photo-reduction of reduced graphene oxide by lanthanoid ion

  • Kim, Jinok;Yoo, Gwangwe;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.290.1-290.1
    • /
    • 2016
  • Grapehen, a single atomic layer of graphite, has been in the spotlight and researched in vaious fields, because its fine mechanical, electrical properties, flexibility and transparence. Synthesis methods for large-area graphene such as chemical vaper deposition (CVD) and mechanical, chemical exfoliation have been reported. In particular, chemical exfoliation method receive attention due to low cost process. Chemical exfoliation method require reduction of graphene oxide in the process of exfoliation such as chemical reduction by strong reductant, thermal reduction on high temperature, and optical reduction via ultraviolet light exposure. Among these reduction methods, optical reduction is free from damage by strong reductant and high temperature. However, optical reduction is economically infeasible because the high cost of short-wavelength ultraviolet light sorce. In this paper, we make graphene-oxide and lanthanoid ion mixture aqueous solution which has highly optical absorbency in selective wevelength region. Sequentially, we synthesize reduced graphene oxide (RGO) using the solution and visible laser beam. Concretely, graphene oxide is made by modified hummer's method and mix with 1 ml each ultraviolet ray absorbent Gd3+ ion, Green laser absorbent Tb3+ ion, Red laser absorbent Eu3+ ion. After that, we revivify graphene oxide by laser exposure of 300 ~ 800 nm layser 1mW/cm2 +. We demonstrate reproducibility and repeatability of RGO through FT-IR, UV-VIS, Low temperature PL, SEM, XPS and electrical measurement.

  • PDF

Preparation and Characterization of β-C3N4 in Presence of Seed Carbon Nitride Films Deposited by Laser-Electric Discharge Method

  • Kim, J.I.;Zorov, N.B.;Burdina, K.P
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.29-33
    • /
    • 2002
  • A procedure was developed for preparing bulk carbon nitride crystals from a polymeric $\alpha$ -C$_3$N$\_$4.2/ at high pressure and temperature in the presence of seeds of crystalline carbon nitride films prepared by a high voltage discharge plasma combined with pulsed laser ablation of graphite target. The samples were evaluated by x-ray photoelectron spectroscopy (XPS), infrared (IR) spectroscopy, Auger electron spectroscopy (AES), secondary-ion mass spectrometry (SIMS), scanning electron microscopy (SEM) and x-ray diffraction (XRD). Notably, XPS studies of the film composition before and after thermobaric treatments demonstrate that the nitrogen composition in $\alpha$ -C$_3$N$\_$4.2/ material initially containing more than 58% nitrogen decreases during the annealing process and reaches a common, stable composition of ~45%. The thermobaric experiments were performed at 10-77 kbar and 350-1200 $\^{C}$.

Laser-Induced Fluorescence Characterization for Real-Time Microplastic Counting (실시간 미세플라스틱 카운팅을 위한 레이저 유도 형광 특성 분석)

  • Ko, Seunghyeon;Oh, Geum-Yoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.149-154
    • /
    • 2022
  • In this paper, laser-induced fluorescence properties of four plastics were characterized through spectrometer analysis for real-time microplastic counting. Recently, environmental problems related to microplastics have emerged. In order to detect microplastics, analysis methods such as FT-IR and Raman are used. However, they have the disadvantages of being time-consuming and requiring a pretreatment process. In most plastic products on the market, 10% to 30% of plasticizers and reinforcing agents are added. Therefore, most microplastics present in seawater and freshwater emit fluorescence signals by 270 nm UV light source regardless of their type due to their molecular structure due to additives. Real-time microplastics counting is possible more easily by using the proposed laser-induced fluorescence detection method because of the fluorescence expression characteristic of 340 nm that appears due to the plasticizer of plastics.

The effects of Exercise and Low-Power Laser on the Changes of CMAP and Histologic factor in Peripheral Nerve Injured Rats (운동과 저출력 레이저가 말초신경손상 흰쥐의 CAMP와 조직학적 변화에 미치는 영향)

  • Ha, Mi-Sook;Baek, Il-Hun;Lee, Hyun-Ok;Kim, Sun-Yueb;Rho, Min-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.4
    • /
    • pp.43-55
    • /
    • 2005
  • This study was performed to investigate the effects of low-power Helium Neon Infra Red(He-Ne IR)laser irradiation and exercise on the regeneration of experimentally cut sciatic nerve in rats. The thrity Sprague-Dawley adult mail rats were assigned to the 6 groups : normal group(1), injured control groups(2), experimental groups(3). There was made artificial injured in the sciatic nerve of rats the each experimental laser group and exercise group were treated from 3 days after being injured for the 5 minutes(laser group), 10 minutes(exercise group), and 15 minutes(exercise and laser group) everyday during 2 weeks. There were measured the changes of amplitude of compound muscle action potential and histological change by the light microscopy on the sciatic nerve injured rats. The results obtained as follows : 1. In the control groups, the regeneration were slowly and slightlly progressed to compared with the experimental groups. Inflammation were much more observed, and fibrous adhesion was also observed around the sutured region of the cut sciatic nerve. 2. The amplitude of compound muscle action potential in the experimental groups were significantly increased to the injured control groups at 1 week(p<.05). The compound muscle action potential of the exercise and lased group was significantly decreased to be similar to normal group at 2 weeks(p<.05). 3. In histologic finding, in the experimental groups were observed the proliferation of the schwann cells, the infiltration of inflammatory cells and the extent of destruction at adjacent tissue were remarkably decreased on the 2 weeks. From these experimental results, it may be suggested that the laser and exercise were effected the heeling process of peripheral nerve injuried rats.

  • PDF

Activation of IL-1β, IGF-1 and IGF-2 in Injured Rat Skeletal Muscle by Low Power He-Ne IR Laser and Electrical Stimulation (저출력레이저와 전기자극에 의한 골격근 손상 흰쥐의 IL-1β, IGF-1, IGF-2 활성)

  • Kim, Jong-Soon;Rho, Min-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.251-262
    • /
    • 2008
  • In this study we investigated the effects of physical therapeutic intervention through electromyography, ultrasonographic imaging and changes of the IL-$1{\beta}$, IGF-1 and IGF-2 in skeletal muscle of rats injured experimentally. The twenty Sprague-Dawley male rats were randomly divided into the 4 groups: a normal, a control, a low power laser and a neuromuscular electrical stimulation group. Abnormal spontaneous activities had not been shown, both in normal and skeletal muscle injured rats. The maximum diameter of the calf muscle was significantly increased in the low power laser and neuromuscular electrical stimulation groups compared with control group. The level of the serum IL-$1{\beta}$ was more decreased in the low power laser and neuromuscular electrical stimulation groups than that of control group. The activation level of the IGF-1 and the IGF-2 were significantly higher in the control, low power laser and neuromuscular electrical stimulation groups than that of normal group. However, there was no statistically significant difference among the control, low power laser and neuromuscular electrical stimulation groups.

Design and Implementation of IR Laser Focus Alignment Algorithms Using CdS (조도센서(CdS)를 활용한 IR레이저 초점정합 알고리즘 설계 및 구현)

  • Lim, Ji-yong;Kim, Gwan-Hyung;Shin, Dong-Suk;Kim, Myeong-Ho;Jeon, Jae-Hwan;Oh, Am-suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.499-500
    • /
    • 2014
  • 화재발생 시 인명 안전을 위하여 초기의 화재감지가 매우 중요한 요인이다. 특히 도로터널, 지하철역사 등 광범위 폐쇄공간에서 연기에 의한 질식사 등 2차 피해의 발생위험이 높다. 이에 최근 광범위 공간에서 적외선 레이저를 활용한 원거리 연기검출 화재탐지기에 대한 연구가 진행되고 있다. 이러한 레이저 기반 원거리 연기검출장치는 이격(100m 이상) 설치되는 레이저 발신기와 수신기의 레이저 포인트가 정확히 정합되어야 한다. 아울러, 레이저 발신기와 수신기 사이의 거리에 비례하여 레이저 초점의 이동거리가 매우 민감하게 변화하므로 이를 정확히 정합하기 위한 고정밀 제어장치가 필요하다. 따라서 본 논문에서는 복수개의 레이저 발신모듈과 복수개의 조도센서(CdS)를 통해 초점의 정합을 자동 추적할 수 있는 알고리즘을 설계, 구현하였다. 이는 초기 레이저 초점의 설정과 이후 외부환경에 따른 초점의 틀어짐을 자동 보정하여 다양한 레이저 인식 장치에 적용될 것으로 사료된다.

  • PDF

Damage detection of composite materials via IR thermography and electrical resistance measurement: A review

  • Park, Kundo;Lee, Junhyeong;Ryu, Seunghwa
    • Structural Engineering and Mechanics
    • /
    • v.80 no.5
    • /
    • pp.563-583
    • /
    • 2021
  • Composite materials, composed of multiple constituent materials with dissimilar properties, are actively adopted in a wide range of industrial sectors due to their remarkable strength-to-weight and stiffness-to-weight ratio. Nevertheless, the failure mechanism of composite materials is highly complicated due to their sophisticated microstructure, making it much harder to predict their residual material lives in real life applications. A promising solution for this safety issue is structural damage detection. In the present paper, damage detection of composite material via electrical resistance-based technique and infrared thermography is reviewed. The operating principles of the two damage detection methodologies are introduced, and some research advances of each techniques are covered. The advancement of IR thermography-based non-destructive technique (NDT) including optical thermography, laser thermography and eddy current thermography will be reported, as well as the electrical impedance tomography (EIT) which is a technology increasingly drawing attentions in the field of electrical resistance-based damage detection. A brief comparison of the two methodologies based on each of their strengths and limitations is carried out, and a recent research update regarding the coupling of the two techniques for improved damage detection in composite materials will be discussed.