• 제목/요약/키워드: I-function

검색결과 5,703건 처리시간 0.037초

A learning control of DC servomotor using neural network

  • Kawabata, Hiroaki;Yamada, Katsuhisa;Zhong, Zhang;Takeda, Yoji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.703-707
    • /
    • 1994
  • This paper proposes a method of learning control in DC servomotor using a neural network. First we estimate the pulse transfer function of the servo system with an unknown load, then we determine the best gains of I-PD control system using a neural network. Each time the load changes, its best gains of the I-PD control system is computed by the neural network. And the best gains and its pulse transfer function for the case are stored in the memory. According the increase of the set of gains and its pulse transfer function, the learning control system can afford the most suitable I-PD gains instantly.

  • PDF

GAUSSIAN QUADRATURE FORMULAS AND LAGUERRE-PERRON@S EQUATION

  • HAJJI S. EL;TOUIJRAT L.
    • Journal of applied mathematics & informatics
    • /
    • 제18권1_2호
    • /
    • pp.205-228
    • /
    • 2005
  • Let I(f) be the integral defined by : $I(f) = \int\limits_{a}^{b} f(x)w(x)dx$ with f a given function, w a nonclassical weight function and [a, b] an interval of IR (of finite or infinite length). We propose to calculate the approximate value of I(f) by using a new scheme for deriving a non-linear system, satisfied by the three-term recurrence coefficients of semi-classical orthogonal polynomials. Finally we studies the Stability and complexity of this scheme.

한국 전통기물을 이용한 Found Objects 개념의 가구디자인 제안 (A Study on Found Objects Furniture with Korean Traditional Objects)

  • 강형구
    • 한국가구학회지
    • /
    • 제16권2호
    • /
    • pp.85-93
    • /
    • 2005
  • There are several way to classify the furniture. The furniture can be classified into use, style, and function, but if the furniture is classified into the way of production, it can be the industrial furniture and the studio furniture. Especially, technology and function of the furniture are important elements in industrial furniture. However, it could be considered artists' character and concept as more important elements in the studio furniture. The studio furniture had come out one of the historical movement in American furniture field after the World War II. This case to apply found objects began to increase after the 1970s. Using objects In furniture design field had built up sprightly after end of 1950s. This expression could be the statement of new expression that essential properties of matter in objects is removed. I try to suggest original and interesting furniture design to apply found objects in this thesis. Especially, I use the Korean traditional objects for the furniture and try to make their essential function to be changed. Also, I focus on furniture design to have formative element in their shapes.

  • PDF

The Inverse Laplace Transform of a Wide Class of Special Functions

  • Soni, Ramesh Chandra;Singh, Deepika
    • Kyungpook Mathematical Journal
    • /
    • 제46권1호
    • /
    • pp.49-56
    • /
    • 2006
  • The aim of the present work is to obtain the inverse Laplace transform of the product of the factors of the type $s^{-\rho}\prod\limit_{i=1}^{\tau}(s^{li}+{\alpha}_i)^{-{\sigma}i}$, a general class of polynomials an the multivariable H-function. The polynomials and the functions involved in our main formula as well as their arguments are quite general in nature. On account of the general nature of our main findings, the inverse Laplace transform of the product of a large variety of polynomials and numerous simple special functions involving one or more variables can be obtained as simple special cases of our main result. We give here exact references to the results of seven research papers that follow as simple special cases of our main result.

  • PDF

CERTAIN SUMMATION FORMULAS FOR HUMBERT'S DOUBLE HYPERGEOMETRIC SERIES Ψ2 AND Φ2

  • CHOI, JUNESANG;RATHIE, ARJUN KUMAR
    • 대한수학회논문집
    • /
    • 제30권4호
    • /
    • pp.439-446
    • /
    • 2015
  • The main objective of this paper is to establish certain explicit expressions for the Humbert functions ${\Phi}_2$(a, a + i ; c ; x, -x) and ${\Psi}_2$(a ; c, c + i ; x, -x) for i = 0, ${\pm}1$, ${\pm}2$, ..., ${\pm}5$. Several new and known summation formulas for ${\Phi}_2$ and ${\Psi}_2$ are considered as special cases of our main identities.

단순선형회귀와 이차형식회귀모형을 중심으로 D-와 이분산 G-최적에 비교한 Iλ-최적실험기준의 특성연구 (Characteristics of Iλ-optimality Criterion compared to the D- and Heteroscedastic G-optimality with respect to Simple Linear and Quadratic Regression)

  • 김영일
    • 품질경영학회지
    • /
    • 제21권2호
    • /
    • pp.140-155
    • /
    • 1993
  • The characteristics of $I_{\lambda}$-optimality, one of the linear criteria suggested by Fedorov (1972) are investigated with respect to the D-and heteroscedastic G-optimality in case of non-constant variance function. Though having limited results obtained from simple models, we may conclude that $I_{\lambda}$-optimality is sometimes preferred to the heteroscedastic G-optimality suggested newly bv Wong and Cook (1992) in the sense that the experimenter's belief in weighting function exists in $I_{\lambda}$-optimality criterion, not to mention its computational simplicity.

  • PDF

배전자동화 개폐기의 Fault Indicator규격 및 운영기법 개선에 관한 연구 (A Study on Improvement of the Specification and Operation Method for Fault Indicator of Distribution Automated Switch)

  • 이중호;하복남;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.861-863
    • /
    • 1998
  • F.I(Fault Indicator) is equipped in automatic switchs for Distibution Automation System(DAS), and plays important role of providing the information for picking out a fault section. The restrictive sentence that F.I doesn't react for the inrush current is in the F.I specification. Nevertheless F.I has sometimes mal-functioned on the DAS in Kang-Dong branch office of KEPCO for latest 2 years. This Paper Proved the causes of the mal-function, and proposed the new F.I specification and operation methods against the mal-function causes.

  • PDF

심근병에서 $^{123}I-MIBG$ 영상을 이용한 교감신경기능의 평가 (Evaluation of Sympathetic Innervation in Cardiomyopathy with $^{123}I-MIBG$)

  • 김선정;이종두;이도연;박창윤;함진경;정남식;조승연;이성숙;김용수
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.195-202
    • /
    • 1993
  • $^{123}Iodine$-metaiodobenzylguanidine (MIBG) which is a norepinephrine analogue, can be used to evaluate the sympathetic innervation of the heart. In this study, cardiac imaging with $^{123}I-MIBG$ was performed in patients with 9 dilated cardiomyopathy, 2 ischemic cardiomyopathy and 1 acute myocardial infarction to evaluate the sympathetic nervous function. $^{123}I-MIBG$ imaging showed multifocal defects (8), diffuse defect (2), near non-visualization (2). The defects of MIBG scans were found to be larger and more severe on 4 hours image than 30 minutes. Heart to lung, heart to mediastinum ratios were decreased at 4 hours than those at 30 minutes. Measured LVEF values were not correlated with the severity of MIBG uptake. $^{99m}Tc-MIBI$ imaging was also performed in all patients to find the relationship with $^{123}I-MIBG$ scan. $^{99m}Tc-MIBI$ scan showed multifocal defects in 9 patients, diffuse defects in 1 patient and no defect in 2 patients. The defects are similar in size, severity and extent, but more larger and severe on $^{123}I-MIBG$ imaging. Therefore, cardiac $^{123}I-MIBG$ imaging is a useful method to evaluate the sympathetic nervous function in cardiomyopathy.

  • PDF

MULTIPLICATIVE FUNCTIONS COMMUTABLE WITH BINARY QUADRATIC FORMS x2 ± xy + y2

  • Poo-Sung, Park
    • 대한수학회보
    • /
    • 제60권1호
    • /
    • pp.75-81
    • /
    • 2023
  • If a multiplicative function f is commutable with a quadratic form x2 + xy + y2, i.e., f(x2 + xy + y2) = f(x)2 + f(x) f(y) + f(y)2, then f is the identity function. In other hand, if f is commutable with a quadratic form x2 - xy + y2, then f is one of three kinds of functions: the identity function, the constant function, and an indicator function for ℕ \ pℕ with a prime p.

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.