• Title/Summary/Keyword: I/d Parameters

Search Result 871, Processing Time 0.039 seconds

A Comparison on the Reproducibility of Parametric Bodies Used in the Virtual Garment System

  • Choi, Hee Eun;Nam, Yun Ja;Kim, Hye Suk
    • Fashion & Textile Research Journal
    • /
    • v.16 no.2
    • /
    • pp.266-274
    • /
    • 2014
  • Parametric bodies reproduce the actual shape of human body parts and should be convenient for general users to change size to judge the visual fit of clothes on-line. In this study, three parametric bodies(i.e. I, C, D ) were compared to verify the accuracy of the provided body dimensions and reproducibility to a target model. To compare reproducibility, the 20s female standard virtual model developed for an apparel industry by Korean agency for technology and standards is used. The investigation of existing parameters showed that the numbers and kinds of parameters provided by each program were different with some errors in notation; in addition, some of virtual body dimensions went beyond the maximum allowable error. The result of changing each parametric body to the 20s female standard body showed that D, C, I in order produced better reproducibility for body dimensions. There were different levels of protrusion and concavity in the virtual cross sections and virtual longitudinal sections despite the small differences in body dimensions and cross sectional areas; in addition, some parametric body was not bilateral symmetry. The results of this study can be used as basic information in the standardization of a virtual model used in a virtual garment program.

Decoupled Location Parameter Estimation of 3-D Near-Field Sources in a Uniform Circular Array using the Rank Reduction Algorithm

  • Jung, Tae-Jin;Kwon, Bum-Soo;Lee, Kyun-Kyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.129-135
    • /
    • 2011
  • An algorithm is presented for estimating the 3-D location (i.e., azimuth angle, elevation angle, and range) of multiple sources with a uniform circular array (UCA) consisting of an even number of sensors. Recently the rank reduction (RARE) algorithm for partly-calibrated sensor arrays was developed. This algorithm is applicable to sensor arrays consisting of several identically oriented and calibrated linear subarrays. Assuming that a UCA consists of M sensors, it can be divided into M/2 identical linear subarrays composed of two facing sensors. Based on the structure of the subarrays, the steering vectors are decomposed into two parts: range-independent 2-D direction-of-arrival (DOA) parameters, and range-relevant 3-D location parameters. Using this property we can estimate range-independent 2-D DOAs by using the RARE algorithm. Once the 2-D DOAs are available, range estimation can be obtained for each source by defining the 1-D MUSIC spectrum. Despite its low computational complexity, the proposed algorithm can provide an estimation performance almost comparable to that of the 3-D MUSIC benchmark estimator.

The Torque-current Observer Design for Speed.Torque Control of DC Motor (직류 전동기 속도.토크 제어에 대한 토크전류 관측기 설계)

  • Kim, Eun-Gi;Kim, Yong-Ju;Seo, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1091-1093
    • /
    • 2002
  • In this paper, the load torque observer is designed for speed and torque control of DC motor. Load torque is very sensitive to the variation and disturbance of the input parameters. The proposed system can accurately estimate the instantaneous speed even at the low speed range by using the load torque observer based on the torque component of DC motor. The system becomes robust against disturbances using a feed-forward control of the load torque estimated automatically at the speed observer.

  • PDF

Adaptive Techniques for Joint Optimization of XTC and DFE Loop Gain in High-Speed I/O

  • Oh, Taehyoun;Harjani, Ramesh
    • ETRI Journal
    • /
    • v.37 no.5
    • /
    • pp.906-916
    • /
    • 2015
  • High-speed I/O channels require adaptive techniques to optimize the settings for filter tap weights at decision feedback equalization (DFE) read channels to compensate for channel inter-symbol interference (ISI) and crosstalk from multiple adjacent channels. Both ISI and crosstalk tend to vary with channel length, process, and temperature variations. Individually optimizing parameters such as those just mentioned leads to suboptimal solutions. We propose a joint optimization technique for crosstalk cancellation (XTC) at DFE to compensate for both ISI and XTC in high-speed I/O channels. The technique is used to compensate for between 15.7 dB and 19.7 dB of channel loss combined with a variety of crosstalk strengths from $60mV_{p-p}$ to $180mV_{p-p}$ adaptively, where the transmit non-return-to-zero signal amplitude is a constant $500mV_{p-p}$.

Microstructural Changes during Activation Process of Isotopic Carbon Fibers using CO2 Gas(I)-XRD Study (이산화탄소를 이용한 등방성 탄소섬유의 활성화과정 중 발생하는 구조변화(I)-XRD를 이용한 분석)

  • Roh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.11
    • /
    • pp.742-748
    • /
    • 2003
  • The structural parameters such as Lc, La and d of $CO_2$activated isotropic carbon fibers(ACFs) were obtained from XRD in order to understand a development mechanism of micropores. And the structural parameters were compared with specific surface area(SSA) data. The $d_{002}$, Lc, and La of the original fiber were measured to be 4.04$\AA$, 6.2$\AA$, and 23.6$\AA$, respectively. Carbonization of outer-parts and oxidization of inner-parts of the original fibers were far from completeness. It was observed that the structural changes of the ACFs during activation take place severely, therefore the carbonization and the oxidization of the fibers take place simultaneous with pore developments. The $d_{002}$ of the ACFs was increased to be 2.80$\AA$, and the La of the ACFs was decreased to be 17.0$\AA$ by activation. It was shown that the pores are developed continuously from the outer-parts to the inner-parts of the fibers, therefore the SSA increases as a result of the development of pores fully to the inner-parts of the fiber when the burn-off degree was over :39%. It seems that the (002) planes of crystallites contribute to the micropore wall related to the super high SSA.SSA.

NEAR INFRARED SPECTROSCOPY, A POWERFUL TECHNIQUE IN HUMAN SKIN STUDY : PART I METHOD RELIABILITY AND INFLUENTIAL PARAMETERS

  • Snieder, Marchel;Wiedemann, Sophie;Hansen, Wei G.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3101-3101
    • /
    • 2001
  • Near Infrared spectroscopy (NIR) used on human skin measurement was explored in the past decade. Many publications in different journals and magazines discussed the feasibility of the NIR technique for cosmetic product property studies. Based upon the results of pioneers, we have pursued some work of the NIR instrument coupled with a probe module for skin measurement in vivo and vitro. In part I of this paper, the specific Near Infrared spectroscopy instrument stability, human subject conditions and other parameters, which could affect the measurements reproducibility are discussed. Second derivative NIR spectra and Principle Components Analysis (PCA) are utilised for data interpretation. In part II of this paper, the relationship of human skin moisture and ageing, the gender information and finally, the discovery of penetration depth of NIR incident light on skin are reported. A theoretical penetration depth calculation equation is proposed. In part III, the study results of a couple of commercial skin care products effect will be described. The skin lotions were applied on human skin (in vivo) in order to exam the NIR feasibility to monitor the changes of moisture level. The results are consistently positive. From our primary study, it can conclude that the NIR is potentially a very powerful instrument for skin condition diagnostics, either for cosmetic and/or for medication purposes.

  • PDF

A Study on the Development of 25.8kV 25kA Gas Circuit Breaker Using Thermal-Expansion Principle (I) (25.8kV 25kA 열팽창분사식 가스차단기 개발에 관한 연구 (I))

  • Song, K.D.;Park, K.Y.;Shin, Y.J.;Chang, K.C.;Kim, K.S.;Kim, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.160-164
    • /
    • 1995
  • In order to develop a medium voltage class gas circuit breaker by our own technology, we designed and manufactured the model interrupters using the hybrid arc extinguishing principle which adopts the thermal expansion principle in the large current region and the arc rotation principle by permanent magnet in the small current region. As the results of the first year research out of three years' research period, the main design parameters such as the volume of thermal expansion chamber, the distance between fixed contact and nozzle, the length of nozzle throat, the nozzle expansion angle and the magnitude of permanent magnet etc. have been determined. 4 types of model interrupters have been designed and manufactured considering the main design parameters. The 25kA short-circuit test and capacitive current breaking test have been performed for the model interrupters and the test results analyzed to improve the model interupters.

  • PDF

The Effect of Noise on the Normal and Pathological Voice (소음환경이 정상 및 병적음성에 미치는 영향)

  • Hong, Ki-Hwan;Yang, Yoon-Soo;Kim, Hyun-Gi
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.27-38
    • /
    • 2002
  • The purpose of this article is to present the acoustic parameters (VOT, jitter, shimmer, vF0, vAm, NHR, SPI, VTI, DVB, DSH) for consonants (/pipi/, /$p^{h}ip^{h}i$/, /p'ip'i/) and sustained vowels (/a/, /e/, /i/) produced by normal subjects and dysphonia patients at two vocal effort(normal, high) by Lombard effect using 60dB white noise. Lombard effect indicates the vocal effort increase in noisy situation. At normal vocal effort, in general the acoustic parameter values of patients are greater than normal. And in noisy situation, significant decrease of acoustic values is seen in normal compared with in dysphonia patients. The clinical implication of this finding, the vocal quality in dysphonia is not compensated by vocal effort as well as normal subjects because of the inefficiency caused by abnormal vocal fold appearance and function. And with this result, we can counsel that the voice quality can not be improved as well as the patient expect.

  • PDF

Quick Detection of Variance Change Point for I.I.D. Data

  • Park, Kyoung-Hwa;Kim, Tae-Yoon;Song, Gyu-Moon;Choi, Jung-Jae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.2
    • /
    • pp.173-183
    • /
    • 2005
  • This paper studies quick detection of variance change point for iid data. For development of sensitive and adaptive variance change point detector, moving variance ratio is employed as a variance ratio estimator. It is shown that selection of tuning parameters of detector, (i.e., information and lag tuning parameters) is critical for detector to achieve desirable sensitivity and adaptiveness. Interestingly our simulation result reveals limitations of the commonly used change ratio against the previous day. Our results will provide useful insight when the detector is applied to time series data.

  • PDF

A Novel Ocular Delivery System for Phenylephrine Hydrochloride

  • Durrani, A.M.;Jamshaid, M.;Kellaway, I.W.
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.386-389
    • /
    • 1996
  • The in vivo behaviour of phenylephrine hydrochloride in different vehicles like gels of Carbopol $907^circledR$, Carbopol $934P^circledR$ and latex system of cellulose acetate hydrogen phthalate(CAHP) was evaluated by measuring the reduction in intraocular pressure and the mydriatic activity. The parameters that haave been utilised to assess the performance of the formulations were the area under the curve (AUC), the maximum mydriasis $(I_{max})$, ethe time of maximum response $(T_{max})$ and the duration of activity (D). The influence of viscosity and mucoadhesion on the bioavailability parameters has also been investigated. Carbopol 934P and CAHP formulations showed prolonged duration of action and greater AUC compared to Carbopol 907 aqueous solution(P<0.05).

  • PDF