• Title/Summary/Keyword: Hysteresis Characteristic

Search Result 183, Processing Time 0.034 seconds

Determination of Soil Water Characteristic Curve and Permeability Equation of Unsaturated Soils Using Modified Triaxial Apparatus (변형된 삼축시험장치를 이용한 불포화토의 함수특성곡선과 투수계수방정식의 결정)

  • Kim Suk-Nam;Park Chi-Won;Mok Young-Jin;Kim Suk-Myung
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.59-64
    • /
    • 2005
  • In studying unsaturated soil mechanics, determination of soil water characteristic curve and permeability equation though not easy, is an essential factor. In this research a new testing apparatus was developed to determine soil water characteristic curve and permeability equation. A test to get saturated permeability coefficients and soil water characteristic curves for two soils was performed by using the developed testing apparatus. First, a saturated permeability test was performed and then the test to get soil water characteristic curve of a drying process was performed. Next, the test to get soil water characteristic curve of a wetting process was performed. Test results showed hysteresis phenomena between soil water characteristic curve of a drying process and soil water characteristic curve of a wetting process. The permeability equations were determined by a theoretical method where a saturated permeability coefficient and a soil water characteristic curve were used.

A Study on Measuring Soil-Water Characteristic Curve Using a Suction Control Technique (흡입력 조절 기법을 이용한 함수특성곡선 측정에 관한 연구)

  • Lee, Joonyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5587-5594
    • /
    • 2012
  • Determination of the soil-water characteristic curve is one of the most important things to solve geotechnical engineering problems. Expecially, convenient and reliable method to measure the soil-water characteristic curve during drying and wetting cycles is required with lower labor input, more independence from operator experience, and shorter testing time than other available methods. Many measurement methods including the flow pump system have been developed to characterize the soil-water characteristic curve for the several decades. This study measured the soil-water characteristic curve during drying and wetting cycles using a suction control technique with the flow pump system. Two test materials were used for determination of the soil-water characteristic curve, and it is concluded that suction control technique is suitable for determination of the soil-water characteristic curve and characterization of the hydraulic hysteresis with varying test conditions. Especially, the suction control technique can reduce error of measurement and save time in measuring the soil-water characteristic curve due to automated system and high degree of precision.

Design of low power TTL-to-CMOS converter (저전력형 TTL-to-CMOS 변환기의 설계)

  • 유창식;김원찬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.128-133
    • /
    • 1994
  • This paper proposes a new TTL-to-CMOS converter which has low power dissipation. This converter has no static power dissipation for typical TTL output voltage levels. The simulatio result shows that the power dissipation is reduced to about 1/20 of conventional level converter using CMOS inverters. It also has hysteresis due to the positive feedback which makes the converter noise immune. The logic threshold voltages in the hysteresis characteristic can be optimized by changing the size ratios of the transistors.

  • PDF

Control of Optical Hysteresis in Block Copolymer Photonic Gels: A Step Towards Wet Photonic Memory Films

  • Kim, Eun-Ju;Gang, Chang-Jun;Jang, Yu-Rim;Senthilkumar, S.;Gang, Yeong-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.279-279
    • /
    • 2010
  • Smart gels have recently associated with photonic crystals to form photonic gels. Since these photonic gels are capable of reversibly converting the volume change of gels induced in response to external chemical or electric stimuli into characteristic optical signals, they have been considered not only as a good platform for label-free chemical or biological detection, actuators or optical switches but also as a good model system to investigate gel swelling behaviour. Recently, we reported block copolymer photonic gels self-assembled from polystyrene-b-poly(2-vinyl pyridine) (PS-b-P2VP) block copolymers, and demonstrated that selective swelling of lamellar structure allows extremely large tunability of the photonic stop band from UV region to IR region ($\lambda$ peak=350~1,600 nm). Herein we report block copolymer photonic gels which exhibit strong tunable optical hysteresis and their applications. As nonlinear responses in swelling of hydrogels were often observed, photonic gels exhibit optical hysteresis with change of external pH. We demonstrate such optical hysteresis can be precisely programmed by controlling ion-pairing affinity. We anticipate that photonic gels with carefully tunned optical hysteresis are applicable to optical memory devices.

  • PDF

Soil Water Characteristic Curve of the Weathered Granite Soil through Simulated Rainfall System and SWCC Cell Test (강우재현 모형실험과 SWCC Cell 실험에 의한 화강암질 풍화토의 함수특성곡선)

  • Ki, Wan-Seo;Kim, Sun-Hak
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.523-535
    • /
    • 2008
  • A simulated rainfall system was built, and the unsaturated characteristics were examined by execution of simulated rainfall system test and soil water characteristic curve cell test(SWCC Cell Test) under the various rainfall and slope conditions. With the results, the applicability of infiltration behavior under rainfall and soil water characteristic curve models to the unsaturated weathered granite soil was examined. At the results of comparison the volumetric water content and matric suction measured in the wetting process(under rainfall) with those in the drying process(leaving as it was) of the simulated rainfall system, the volumetric water content showed a difference of $2{\sim}5%$ and matric suction of about $3{\sim}10\;kPa$, indicating the occurrence of hysteresis. In addition, the difference was relatively larger in matric suction than in the volumetric water content, and this tells that the hysteresis behavior is larger in matric suction. When the soil water characteristic curve derived from measurements in simulated rainfall system test were compared with those from the soil water characteristic curve cell test, both methods produced soil water characteristic curves close each other in the wetting process and the drying process, but in both, there was a difference between results obtained from in the wetting process and those from in the drying process. Thus, when soil water characteristic curves are rationally applied to the design and stability analysis considering of the properties of unsaturated soil, it is considered desirable to apply the soil water characteristic curve of the wetting process to the wetting process, and that of the drying process to the drying process.

The variable hysteresis modeling circuit for spintronic device (자성반도체의 가변 히스테리시스 특성 모델링 회로)

  • Hwang WonSeok;cho Chung-Hyun;kim Bumsoo;Lee GabYong;Lee ChangWoo;Kim Dong Myong;Min Keung-Sik;Kim Daejeong
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.447-450
    • /
    • 2004
  • The modeling circuit becomes more important in developing various magnetic devices regarding the fact that the competitive architecture and circuitry should be developed simultaneously. In this paper, we introduce a modeling circuit for hysteresis characteristic of a magnetic device, which is a major characteristic in the spin dependent magnetic material. This transistor-level model is conspicuous in that it can be usefully embodied in real circuits rather than conventional SPICE models are only for simulations.

  • PDF

Memory Characteristic Measurement of Electroluminescent Device using V-Q Lissajous' Figure (V-Q lissajous 도형을 이용한 전계발광 소자의 메모리 특성 측정)

  • Jeong, D.Y.;Lim, M.S.;Yun, S.H.;Shin, Y.S.;Kwon, S.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1783-1785
    • /
    • 1999
  • In this paper, we apply V-Q Lissajoucs' figure for observation of a V-Q (Voltage-Charge) hysteresis loop at interface between phosphor and insulation layer in P-ELDz which are a simple structure and the back lighting of LCDs (Liquid Crystal Display). In V-Q Lissajous' figure, we measured a change of hysteresis loop according to the thickness of Insulation and phosphor layer. From experiment result, we will be obtained a optimum thickness of insulation with comparing the correlation of a V-L (Voltage-Luminance) and V-Q hysteresis loop.

  • PDF

A Position Control System of SRM using Digital Hysteresis Controller (디지털 히스테리시스 제어기를 이용한 SRM의 위치제어시스템)

  • Baik Won-Sik;Kim Nam-Hun;Choi Kyeong-Ho;Kim Dong-Hee;Kim Min-Huei;Hwang Don-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.41-45
    • /
    • 2001
  • This paper presents an implementation of motion control system of Switched Reluctance Motor (SRM) using digital hysteresis controller by TMS320F240 DSP. SRM position control system possess several advantages over other motors, including high efficiency, simple structure, low cost, and four-quadrant operation at a wide speed range, especially for the servo drive systems with precision, stability and fast response characteristics in the industrial applications. In the suggested motion control system, position control using digital hysteresis controller is developed, and is evaluated using experimental testing. The developed system for cost reduction and high-performance by fully digital controller is shown a good response characteristic of motion control results.

  • PDF

Current and voltage characteristics of inverted staggered type amorphous silicon thin film transistor by chemical vapour deposition (CVD증착에 의한 인버티드 스태거형 TFT의 전압 전류 특성)

  • 이우선;박진성;이종국
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1008-1012
    • /
    • 1996
  • I-V, C-V characteristics of inverted staggered type hydrogenerated amorphous silicon thin film transistor(a-Si:H TFT) was studied and experimentally verified. The results show that the log-log plot of drain current increased by voltage increase. The saturated drain current of DC output characteristics increased at a fixed gate voltage. According to the increase of gate voltage, activation energy of electron and the increasing width of Id at high voltage were decreased. Id saturation current saturated at high Vd over 4.5V, Vg-ld hysteresis characteristic curves occurred between -15V and 15V of Vg. Hysteresis current decreased at low voltage of -15V and increased at high voltage of 15V.

  • PDF

Precision Position Control of a Piezoelectric Actuator Using Neural Network (신경 회로망을 이용한 압전구동기의 정밀위치제어)

  • Kim, Hae-Seok;Lee, Byung-Ryong;Park, Kyu-Youl
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.11
    • /
    • pp.9-15
    • /
    • 1999
  • A piezoelectric actuator is widely used in precision positioning applications due to its excellent positioning resolution. However, the piezoelectric actuator lacks in repeatability because of its inherently high hysteresis characteristic between voltage and displacement. In this paper, a controller is proposed to compensate the hysteresis nonlinearity. The controller is composed of a PID and a neural network part in parallel manner. The output of the PID controller is used to teach the neural network controller by the unsupervised learning method. In addition, the PID controller stabilizes the piezoelectric actuator in the beginning of the learning process, when the neural network controller is not learned. However, after the learning process the piezoelectric actuator is mainly controlled by the neural netwok controller. In this paper, the excellent tracking performance of the proposed controller was verified by experiments and was compared with the classical PID controller.

  • PDF