• Title/Summary/Keyword: Hydrophobic/hydrophilic surface

Search Result 310, Processing Time 0.025 seconds

Electroless Nickel Plating on Porous Carbon Substrate (다공성 탄소전극기지상의 무전해 니켈도금에 관한 연구)

  • Chun, So-Young;Rhyim, Young-Mok;Kim, Doo-Hyun;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.75-80
    • /
    • 2010
  • Electroless nickel plating on porous carbon substrate was investigated. The pore sizes of carbon substrates were 16-20 ${\mu}m$ and over 20 ${\mu}m$. The carbon surface was changed from hydrophobic to hydrophilic after immersing the substrate in an ammonia solution for 40 min at $60^{\circ}C$. The contact angle of water was decreased from $85^{\circ}$ to less than $20^{\circ}$ after ammonia pretreatment. The content of phosphorous in nickel deposit was decreased with increasing pH and then deposits became crystallized. The thickness of nickel deposit was increased with increasing pH. The minimum concentration of $PdCl_2$ for the electroless nickel plating was 5 ppm and the thickness of nickel was not significantly affected by the concentration of $PdCl_2$.

The improvement of Cu metal film adhesion on polymer substrate by the low-power High-frequency ion thruster

  • Jung Cho;Elena Kralkina;Yoon, Ki-Hyun;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.60-60
    • /
    • 2000
  • The adhesion interface formation between copper and poly(ethylene terephthalate)(PET), poly(methyl methacrylate)(PMMA) and Polyimide films was treated using Ion assisted reaction system to sequential sputter deposition by High-Frequency ion source. The ion beam modification system used a new type of low power HF ion thruster for space application as new low thruster electric propulsion system. Low power HF ion thruster with diameter 100mm gives the opportunity to obtain beams of Ar+ with currents 20~150 mA (current density 0.5~3.5 mA/cm2) and energy 200~2500eV at HF power level 10~150 W. Using Ar as a working gas it is possible to obtain thrust within 3~8 mN. Contact angles for untreated films were over 95$^{\circ}$ and 80 for Pet, 10o for PMMA and 12o for PI samples as a condition of ion assisted reaction at the ion dose of 10$\times$1016 ions/cm2, the ion beam potential of 1.2 keV and 4 ml/min for environmental gas flow rate. 900o peel tests yielded values of 15 to 35 for PET, 18 to 40 and 12 to 36 g/min. respectively. High resolution X-ray photoelectron spectrocopy is the Cls region for Cu metal on these polymer substrates showed increases in C=O-O groups for polymide, whereas PET and PMMA treated samples showed only C=O groups with increase the ion dose. Finally, unstable polymer surface can be changed from hydrophobic to hydrophilic formation such as C-O and C=O that were confirmed by the XPS analysis, conclusionally, the ion assisted reaction is very effective tools to attach reactive ion species to form functional groups on C-C bond chains of PET, PMMA and PI.

  • PDF

Precise Static Contact Angle Measurements Using Pythagolas Rule (피타고라스 원리를 이용한 정적 접촉각 정밀 각도 측정방법)

  • Choi, Jin-Yeong;Kwon, Dong-Jun;Wang, Zuo-Jia;Shin, Pyeong-Su;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.15 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • Pythagolas rule was used for investigation of static contact angle in particular figures. Static contact angle measurement was important to evaluate the wettability between solid and liquid. Optimum measurement method and standardization of calculation for static contact angle were investigated for practical application. Optimum diameter of droplet for static contact angle measurement was confirmed as 1 mm. Contact angle measurement using Pythagolas rule was also used to calculate advancing, receding angle and wettability of different surface condition. At last, it was concluded that the Pythagolas rule method was more accurate than general lineation method for static contact angle measurement.

Electro-optical characteristic analysis of liquid crystal cell using UV-treated self assembled monolayer (UV 처리된 자기 조립 단분자막을 사용한 액정 셀의 전기광학특성 분석)

  • Chan-Woo Oh;Hong-Gyu Park
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • In this paper, we demonstrated the orientation characteristics of liquid crystals using UV-treated FSAM as alignment layer. Moreover we confirmed the FSAM properties before and after UV treatment on indium tin oxide (ITO) glass substrates using physicochemical analysis. The hydrophobic property of the FSAM surface is change to hydrophilic through UV treatment. After UV treatment the LC molecules also were uniformly and horizontally aligned on the FSAM surfaces and the pretilt angle was obviously changed 90° degrees to 0° degrees. EO characteristic of TN cell which was fabricated with UV-treated FSAM was faster response time compare to conventional PI layer. The FSAM before and after UV treatment has a superior application potential as the LC alignment layer for LCD, potentially replacing the conventional polyimide layer.

Measurements of the Temperature Coefficient of Resistance of CVD-Grown Graphene Coated with PEI (PEI가 코팅된 CVD 그래핀의 저항 온도 계수 측정)

  • Soomook Lim;Ji Won Suk
    • Composites Research
    • /
    • v.36 no.5
    • /
    • pp.342-348
    • /
    • 2023
  • There has been increasing demand for real-time monitoring of body and ambient temperatures using wearable devices. Graphene-based thermistors have been developed for high-performance flexible temperature sensors. In this study, the temperature coefficient of resistance (TCR) of monolayer graphene was controlled by coating polyethylenimine (PEI) on graphene surfaces to enhance its temperature-sensing performances. Monolayer graphene grown by chemical vapor deposition (CVD) was wet-transferred onto a target substrate. To facilitate the interfacial doping by PEI, the hydrophobic graphene surface was altered to be hydrophilic by oxygen plasma treatments while minimizing defect generation. The effect of PEI doping on graphene was confirmed using a back-gated field-effect transistor (FET). The CVD-grown monolayer graphene coated with PEI exhibited an improved TCR of -0.49(±0.03) %/K in a temperature range of 30~50℃.

Preparation of in situ Patterned ZnO Thin Films by Microcontact Printing (Microcontact Printing을 이용한 미세패턴 ZnO 박막 제조)

  • 임예진;윤기현;오영제
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.7
    • /
    • pp.649-656
    • /
    • 2002
  • In situ patterned zinc oxide thin films were prepared by precipitation of Zn(NO$_3$)$_2$ aqueous solution containing urea and by microcontact printing using Self-Assembled Monolayers(SAMs) on A1/SiO$_2$/Si substrates. The visible precipitation of Zn(OH)$_2$ that was formed in the Zn(NO$_3$)$_2$ aqueous solution containing urea was enhanced with an increase of the reaction temperature and the amount of urea. As the reaction time of Zn(NO$_3$)$_2$ with urea was prolonged, the thickness and grain size of Zn(OH)$_2$ thin layers were increased, respectively. The optimum precipitation condition was at 80$\^{C}$ for 1 h for the solution with the ratio of Zn(NO$_3$)$_2$ to urea of 1 : 8. Homogeneous ZnO thin films were fabricated by the heat treatment of 600$\^{C}$ for 1 h of Zn(OH)$_2$ precipitation on Al/SiO$_2$/Si substrate. This was available to the in-situ patterned ZnO thin films with uniform grain size. Hydrophobic SAM, Octadecylphosphonic Acid(OPA) and hydrophilic SAM, 2-Carboxyethylphosphonic Acid(CPA) were applied on the Al/SiO$_2$/Si substrate by microcontact printing method. In situ patterned ZnO thin film was successfully prepared by the heat treatment of Zn(OH)$_2$ precipitated on the surface of hydrophilic SAM, CPA.

Surface Modification of Proton Exchange Membrane by Introduction of Excessive Amount of Nanosized Silica (과량 실리카 도입을 통한 고분자 전해질막 표면 개질)

  • Park, Chi Hoon;Kim, Ho Sang;Lee, Young Moo
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.301-310
    • /
    • 2014
  • In this study, the silica nanoparticles were considerably chosen to improve a dimensional stability, proton transport and electrochemical performance of the resulting inorganic-organic nanocomposite membranes. For this purpose, hydrophobic silica (Aerosil$^{(R)}$ 812, Degussa) and hydrophilic silica (Aerosil$^{(R)}$ 380, Degussa) nanoparticles were, respectively, introduced into a Sulfonated poly(arylene ether sulfone) (SPAES) polymer matrix. The $SiO_2$ particles are evenly dispersed in a SPAES matrix by the aid of a non-ionic surfactant (Pluronics$^{(R)}$ L64). A $SiO_2$ content plays an important role in membrane microstructures and membrane properties such as proton conductivity and water uptake. Therefore, to study nanocomposite membranes with excessive amount of silica, the content of silica nanoparticles were increased up to 5 wt%. Interestingly, a hydrophobic $SiO_2$ containing nanocomposite membrane showed better electrochemical performance (29% higher than pristine SPAES) despite of low proton conductivity due to its adhesive properties with a catalyst layer in a single cell test. All the silica-SPAES membranes exhibited better performance than a pristine SPAES membrane.

Preparation of Amino Acid Copolymers/water-insoluble Drug Nanoparticles: Polymer Properties and Processing Variables (아미노산 공중합체/난용성 약물 나노입자의 제조: 고분자 특성 및 가공변수)

  • Yoo Ji Youn;Lee Soo-Jeong;Ahn Cheol-Hee;Choi Ji-Yeun;Lee Jonghwi
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.440-444
    • /
    • 2005
  • An increase in the surface area of drugs by reducing particle sizes from microns to nanometers has been known as an efficient method to improve the bioavailability of water-insoluble drugs. To prevent drug nanoparticles from aggregation during the processes of drug formulation, a limited number of pharmaceutical inactive ingredients such as hydroxypropyl cellulose has been employed as stabilizers or dispersants. In this study, copolymers of hydrophilic and hydrophobic amino acids were synthesized by the ring opening polymerization of their N-carboxyanhydride monomers and evaluated as novel candidates to stabilize the nanoparticles of a water insoluble drug, naproxen. Naproxen nanoparticles stabilized by synthesized amino acid copolymers were successfully prepared in the size of $200\~500nm$ in 60 min by a wet comminution process. Particle size analysis showed that the effective stabilization performance of copolymers required the hydrophobic moiety content to be higher than $10 mol\%$. However, the molecular weight and morphology of copolymers was not the critical parameters in determining the particle size reduction. Their particle size was found to be stable up to 14 days without significant aggregation.

A Study on the Change of the Adsorption Process of VOCs in the Materials Prepared from the Intercalation Reaction (층간 삽입반응으로 얻어진 화합물을 이용한 휘발성 유기화합물의 흡착과정 변화에 대한 연구)

  • Ahn, Beom-Shu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.799-806
    • /
    • 2017
  • The potential use of modified clays in the adsorption of vapor phase benzene and toluene was investigated. The modified clays OC-CPC, IOC, and Al-PILC were prepared for comparative purposes and were characterized using infrared spectroscopy, thermogravimetric analysis, and X-ray diffraction. It was confirmed the intercalation of the aluminium pillar in IOC and Al-PILC, as well as the introduction of cetylpyridinium. The adsorption studies showed a great affinity of benzene and toluene for OC-CPC due to the hydrophobic character that resulted and also to the increase in the interlaminar distance. IOC showed a lower affinity for the benzene and toluene, followed by Al-PILC. Natual clay had no affinity for benzene and toluene due to its hydrophilic nature. Clay materials having a laminar structure can be chemically modified, changing their physiochemical characteristics, such as interlaminar distance, surface area, pore size, and chemical affinity. In this study, it was focused on obtaining modified clays to be used for the adsorption of volatile organic chemicals.

Enhancement of Penetration by Using Mechenical Micro Needle in Textile Strain Sensor (텍스타일 스트레인 센서에 마이크로 니들을 이용한 전도성입자 침투력 향상)

  • Hayeong Yun;Wonjin Kim;Jooyong Kim
    • Science of Emotion and Sensibility
    • /
    • v.25 no.4
    • /
    • pp.45-52
    • /
    • 2022
  • Recently, interest in and demand for sensors that recognize physical activity and their products are increasing. In particular, the development of wearable materials that are flexible, stretchable, and able to detect the user's biological signals is drawing attention. In this study, an experiment was conducted to improve the dip-coating efficiency of a single-walled carbon nanotube dispersion solution after fine holes were made in a hydrophobic material with a micro needle. In this study, dip-coating was performed with a material that was not penetrated, and comparative analysis was performed. The electrical conductivity of the sensor was measured when the sensor was stretched using a strain universal testing machine (Dacell Co. Ltd., Seoul, Korea) and a multimeter (Keysight Technologies, Santa Rosa, CA, USA) was used to measure resistance. It was found that the electrical conductivity of a sensor that was subjected to needling was at least 16 times better than that of a sensor that was not. In addition, the gauge factor was excellent, relative to the initial resistance of the sensor, so good performance as a sensor could be confirmed. Here, the dip-coating efficiency of hydrophobic materials, which have superior physical properties to hydrophilic materials but are not suitable due to their high surface tension, can be adopted to more effectively detect body movements and manufacture sensors with excellent durability and usability.