• 제목/요약/키워드: Hydrogen ion concentration

검색결과 235건 처리시간 0.036초

염화 제1구리와 제2구리 혼합용액의 이온평형 (Ionic Equilibria in Mixed Solutions of Cuprous and Cupric Chloride)

  • 이만승
    • 대한금속재료학회지
    • /
    • 제46권1호
    • /
    • pp.20-25
    • /
    • 2008
  • The ionic equilibira in mixed solutions of cuprous and cupric chloride were analyzed by considering chemical equilibria, mass and charge balance equations. The activity coefficients of solutes were calculated by using Bromley equation. Required thermodynamic constants and interaction parameters were evaluated from the data reported in the literature. The effect of NaCl and CuCl concentrations on the pH and potential of the mixed solutions was explained in terms of the variation in the concentration of solutes and in the activity of hydrogen ion. The calculated pH values of the mixed solutions agreed well with the measured values. However, the calculated values for the potential of the mixed solutions were lower than the measured values, indicating the necessity of considering the complex formation between cuprous and chloride ion, such as $Cu^2Cl{_4}^{2-}$ and $Cu_3Cl{_6}^{3-}$.

뱀장어(Anguilla japonica) 추출 Carnosine이 과산화수소로 유도된 인체 백혈구의 DNA 손상과 Repair에 미치는 효과 (The Effect of Carnosine Extracted from Eels Anguilla japonica on Oxidative DNA Damage Induced by Hydrogen Peroxide and the DNA Repair Capacity of Human Leukocytes)

  • 송호수
    • 한국수산과학회지
    • /
    • 제50권5호
    • /
    • pp.520-526
    • /
    • 2017
  • Carnosine was recently reported to protect against the DNA damage induced by oxidative stress. In this study, we investigated the protective effect of eel Anguilla japonica carnosine extracts prepared using different methods (heat treatment extracts, HTEs; ion exchange chromatography, IEC; ultrafiltration permeation, UFP) on leukocyte DNA damage using the comet assay. Human leukocytes were incubated with extracts of eel carnosine at concentrations (of 10, 50, $100{\mu}g/mL$), and then subjected to an oxidative stimulus [$200{\mu}M$ hydrogen peroxide ($H_2O_2$)]. Pretreatment of the cells for 30 min with carnosine significantly reduced the genotoxicity of $H_2O_2$ measured as DNA strand breaks. The protective effects of the three types of extract (HTE, IEC, and UFP) increased with concentration. At the highest concentration (100 g/mL). there were no statistical differences in oxidative damage between each extract treatment and PBS-treated negative controls. When leukocytes were incubated with carnosine for 30 min after exposure to $H_2O_2$. the protective ability of each extract changed. Therefore, eel carnosine inhibits the $H_2O_2$ induced damage to cellular DNA in human leukocytes, supporting the protective effect of this compound against oxidative damage.

화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량 (Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method)

  • 김경민;장택균;김영호;오상협;이상학
    • 분석과학
    • /
    • 제24권4호
    • /
    • pp.243-248
    • /
    • 2011
  • 루미놀 화학발광 시스템(luminol-$H_2O_2$)을 이용하여 수용액 중의 수은(II) 이온을 선택적으로 정량분석 하였다. 루미놀과 과산화수소의 반응에서 촉매작용을 하는 구리(II), 철(III), 크롬(III) 이온 등 다양한 금속이온의 농도를 정량분석한 연구결과가 보고되어 있다. 본 연구에서는 수은(II) 이온이 루미놀과 과산화수소의 반응에서 다른 금속이온과 같이 촉매작용을 하는 것을 관찰하였으며, 수용액 중 수은(II) 이온의 정량분석 조건을 최적화하기 위하여 반응시간, pH등에 따른 영향을 조사하였다. 또한 수은이온이 갖는 1가와 2가 산화수 중에서 수은(I) 이온은 루미놀과 과산화수소의 반응에 있어서 촉매작용을 하지 않았을 뿐만 아니라 반응에 어떠한 영향도 미치지 않았다. 또한 수은(I)과 수은(II) 이온이 공존하는 수용액 중의 수은(II) 이온의 분석과정에서 수은(I) 이온의 방해 효과는 관찰되지 않았다. 이를 바탕으로 하여 루미놀 화학발광 시스템을 이용하여 수용액 중의 수은(II) 이온만 선택적으로 분석하는 것이 가능하다는 결과와 함께 화학발광분석법과 ICP분석법으로부터 얻은 실험결과를 비교하여 수용액 내에 존재하는 수은 이온의 산화수별 농도를 확인할 수 있다. 루미놀 화학발광 시스템의 최적 분석조건 하에서, 수용액 중의 선택적 수은(II) 이온의 정량분석을 위해 얻은 검정곡선에서 직선성이 성립하는 농도범위는 $1.25{\times}10^{-5}{\sim}2.50{\times}10^{-3}M$이며, 이때 상관계수는 0.991이고, 검출한계는 $1.25{\times}10^{-7}M$이었다.

20대 여대생을 대상으로 한 치아우식활성검사 연구 (A Study on Dental Caries Activity Test Targeting Female Undergraduates in Their 20s)

  • 윤미숙;윤혜정
    • 치위생과학회지
    • /
    • 제10권6호
    • /
    • pp.465-472
    • /
    • 2010
  • 본 연구에서는 20대 여대생에게 개인에 따라 치아우식증 발생에 작용하는 서로 다른 요인을 찾아내기 위해 치아우식병 발생요인 중 타액요인을 집중적으로 분석하고자 타액분비율, 타액점조도, 타액완충능을 조사하였으며, 치면세균막내 산체류도 치아우식증에 큰 영향을 주기에 치면세균막 수소이온농도를 함께 조사 하여 비교 분석한 결과는 다음과 같다. 다음과 같은 분석결과는 20대 여대생의 치아우식활성검사 결과판독의 기초자료를 제공하고, 치아우식증 발생요인을 규명하는데 기초자료를 제공하고자 실시되었다. 1. 조사 대상자의 평균 우식치아는 1.67개 이었으며, 치아우식으로 인한 발거치아는 0.47개 충전치아는 6.31개로 나타났다. 따라서 평균 영구치우식경험치아는 8.44개로 조사되었다. 2. 치아우식활성검사 방법에 따른 성적으로는 평균 자극성타액분비량은 $12.56{\pm}4.15ml$, 비자극성타액분비량은 $3.89{\pm}1.83ml$, 타액점조도는 $1.49{\pm}0.69$, 타액완충능은 $8.51{\pm}2.44$, 치면세균막 수소이온농도검사는 양치전 $5.62{\pm}0.50$, 양치후 5분 $5.23{\pm}0.58$, 양치후 10분 $5.25{\pm}0.56$, 양치후 15분 $5.29{\pm}0.62$, 양치후 20분 $5.34{\pm}0.58$, 양치후 25분 $5.40{\pm}0.53$, 양치후 30분 $5.61{\pm}0.59$로 나타났다. 3. 자극성타액 및 비자극성타액 분비량, 타액점조도, 타액완충능은 비우식집단이 우식집단 보다 높게 나타났으나, 통계적으로는 유의하지 않았다. 치면세균막 수소이온 농도는 진행 중인 치아우식증이 있는 자와의 관계에서도 전체적으로 통계적인 유의성을 나타내지 않았으나, 비우식집단이 우식집단보다 높게 나타났다. 4. 우식활성검사방법간의 상관관계는 자극성타액분비량은 비자극성 타액분비량과는 유의한 양의 상관이 있었으며(p<0.001), 비자극성타액분비량은 타액완충능과 음의 상관을 나타냈다(p<0.01). 치면세균막 수소이온농도 검사는 양치후 시간이 경과함에 따라 양의 상관을 보였으나, 타액점조도 및 타액완충능과는 유의한 상관이 없었다(p>0.05).

Thienyl Chalcone 유도체의 가수분해 반응메카니즘과 그 반응속도론적 연구 (The Kinetics and Mechanism of the Hydrolysis to Thienyl Chalcone Derivatives)

  • 황용현;이기창;김진영
    • 한국응용과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.73-80
    • /
    • 1993
  • The hydrolysis reaction kinetics of 2-thienyl chalcone derivatives $[II]{\sim}[V]$ was investigated by ultraviolet spectrophotometery in 20% dioxane-$H_2O$ at $25^{\circ}C$ and the structure of these compounds were ascertained by means of ultraviolet, infrared and NMR spectra. The rate equations which were applied over a wide pH range(pH $1.0{\sim}13.0$) were obtained. The substituent effects on 2-thienyl chalcone derivatives$[II]{\sim}[V]$ were studied, and the hydrolysis were facilitated by electron attracting groups. On the basis of the rate equation, substitutent effect and final product, the plausible hydrolysis reaction mechanism was proposed : At pH $1.0{\sim}9.0$, not relevant to the hydrogen ion concentration, neutral $H_2O$ molecule competitvely attacked on the double bond. By contraries, above pH 9.0, it was proportional to concentration of hydroxide ion.

몰리브덴의 용액화학 (Aqueous Chemistry of Molybdenum)

  • 이만승;최승훈
    • 자원리싸이클링
    • /
    • 제27권4호
    • /
    • pp.44-49
    • /
    • 2018
  • 몰리브덴은 알칼리용액에서는 $MoO{_4}^{2-}$로 존재한다. 수용액의 pH 2와 6 사이의 범위에서는 $MoO{_4}^{2-}$와 수소이온간의 축중합반응에 의해 다양한 동종다중음이온이 형성된다. 몰리브덴용액의 pH가 2 이하의 범위에서는 동종다중양이온이 형성되나 무기산의 농도가 증가함에 따라 무기산의 음이온과 반응하여 이종다중음이온이 형성된다. pH 6 이하의 용액에서 몰리브덴의 농도분포는 몰리브덴과 무기산의 종류와 농도에 의존한다. 따라서 용매추출과 이온교환자료를 해석하기 위해서는 강산용액에서 몰리브덴 화학종을 규명할 필요가 있다.

생체내의 혈중이온농도 예측을 위한 마이크로 pH-ISFET프로브의 개발 (Development of a Micro pH-ISFET Probe for in vivo Measurements of the Ion Concentration in Blood)

  • 손병기;이종현;이광만
    • 대한전자공학회논문지
    • /
    • 제23권1호
    • /
    • pp.83-90
    • /
    • 1986
  • A micro pH-ISFET probe, which can be applied to the in vivo measurements of the hydrogen ion concentration in blood, has been developed, and a measuring system equiped with this probe also developed. The pH-ISFET has been fatricated by employing the techniques of integrated circuit fabrication. Two kinds of micro electrode formed around the sensing gate during the wafer process, and the other is a capillary type of Ag/AfCl/sat. KCI reduced in size. This capillary electrode has shown its good performance characteristics so far in the application with ISFET as well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and the capillary electrode were built together into a needle tip having 1 mm inner diameter. The chip size of a twin pH-ISFET is 0.8 mmx1.4 mm, the material of the sensing gate membrane is Si3N4, and the sensitivity of the developed probe is about 52mV/pH.

  • PDF

산소분자의 전기분해법을 도입한 ISFET 포도당센서의 회복특성 개선 (An Improvement of Recovery Characteristics of ISFET Glucose Sensor by Employing Oxygen Electrolysis)

  • 박근용;최상복;이영철;이민호;손병기
    • 센서학회지
    • /
    • 제9권3호
    • /
    • pp.203-207
    • /
    • 2000
  • ISFET 포도당센서는 전류법적인 엑츄에이션(amperometric actuation)기법을 도입하여 감도 향상에 큰 이점을 얻을 수 있었다. 그러나 이러한 측정법은 측정 후, 감지막 내부와 외부사이에 화학적 평형상태를 유지하려는 수소이온의 이동 때문에 초기 출력 값을 회복하는 데 많은 시간을 필요로 한다. 이러한 회복시간 지연문제는 센서의 실용화 장애 요인 중 하나이다. 본 논문에서는 백금작업전극에 환원전위를 인가하여 수산화($OH^-$)이온을 인위적으로 발생시킴으로써 감지막 내의 수소이온 농도를 조절하는 새로운 방법을 제안하였다. 제안된 방법으로 실험한 결과, 기존에 수십 분 소요되었던 회복시간을 2분 이내로 단축하였다.

  • PDF

Hydrogen Plasma Characteristics for Photoresist Stripping Process in a Cylindrical Inductively Coupled Plasma

  • Yang, Seung-Kook;Cho, Jung Hee;Lee, Seong-Wook;Lee, Chang-Won;Park, Sang-Jong;Chae, Hee-Sun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.387-394
    • /
    • 2013
  • As the feature size of integrated circuits continues to decrease, the challenge of achieving an oxidation-free exposed layer after photoresist (PR) stripping is becoming a critical issue for semiconductor device fabrication. In this article, the hydrogen plasma characteristics in direct plasma and the PR stripping rate in remote plasma were studied using a $120{\Phi}$ cylindrical inductively coupled plasma source. E mode, H mode and E-H mode transitions were observed, which were defined by matching the $V_{rms}$ and total impedance. In addition, the dependence of the E-H mode transition on pressure was examined and the corresponding plasma instability regions were identified. The plasma density and electron temperature increased gradually under the same process conditions. In contrast, the PR stripping rate decreased with increasing proportion of $H_2$ gas in mixed $H_2/N_2$ plasma. The decrease in concentration of reactive radicals for the removal of PR with increasing $H_2$ gas flow rate suggests that NH radicals have a dominant effect as the main volatile product.

Respondence Between Electrochemicl Fluctuations and Phenomenon for Localized Corrosion of Less-Noble Metals

  • Itoi, Yasuhiko;Take, Seisho;Tsuru, Tooru
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.35-39
    • /
    • 2008
  • We have been studying application of electrochemical noise (Fluctuation) analysis for localized corrosion. Foils of Zinc, Aluminum and Magnesium were used as specimens for electrochemical cell simulating localized corrosion. These specimens were dipped in sodium chloride solutions adjusted to each exponent of Hydrogen ion concentration (pH) condition of 5.5, 10, 12 respectively. Time variations of potential and current were measured in those solutions, and simultaneously the surfaces of specimens were observed using microscope with television monitor. Two types of electrochemical cells were arranged for experiments simulated localized corrosion. The fluctuations on trendy component of short-circuited potential and short-circuited current were appeared in synchronization. It was seemed that these fluctuations result from hydrogen evolution on the aluminum active site in the crevice from the microscopic observation. In the case of zinc and magnesium, fluctuations appeared on the trendy component of the corrosion potential. Two types fluctuation were detected. First one is the fluctuation varied periodically. The second one is the random fluctuation. It was seemed that these fluctuations result from generation of corrosion products and hydrogen evolution on the active site in the crevice of zinc and magnesium from the microscopic observation.