• Title/Summary/Keyword: Hybrid waveform

Search Result 44, Processing Time 0.03 seconds

Vortex-induced vibration characteristics of multi-mode and spanwise waveform about flexible pipe subject to shear flow

  • Bao, Jian;Chen, Zheng-Shou
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.163-177
    • /
    • 2021
  • Numerical simulations of the Vortex-Induced Vibration (VIV) about a large-scale flexible pipe subject to shear flow were carried out in this paper. Efficiency verification was performed firstly, validating that the proposed fluid-structure interaction solution strategy is competent in predicting the VIV response. Then, the VIV characteristics related to multi-mode and spanwise hybrid waveform about the flexible pipe attributed to shear flow were investigated. When inflow velocity rises, higher vibration modes are apt to be excited, and the spanwise waveform easily convertes from a standing-wave-dominated status to a hybrid standing-traveling wave status. The multi-mode or even multiple-dominant-mode is prone to occur, that is, the dominant mode is often followed by several apparent subordinate modes with considerable vibration energy. Hence, the shedding frequencies no longer obey Strouhal law, and vibration trajectories become intricate. According to the motion analysis concerning the coupled cross-flow and in-line vibrations, as well as the corresponding wake patterns, a tight coupling interaction exists between the structural deformation and the wake flow behind the flexible pipe. In addition, the evolution of the vortex tube along the pipe span and a strong 3D effect are observed due to the slenderness of the flexible pipe and the variability of the vortex shedding attributed to the shear flow.

On a Study of the Reduction of Bit Rate by the Preprocessing of PSOLA Coding Technique in the G. 723.1 Vocoder (PSOLA 전처리과정을 이용한 G.723.1 보코더의 전송률 감소에 관한 연구)

  • 장경아;조성현;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.401-404
    • /
    • 2002
  • In general, speech coding methods are classified into the following three categories: the waveform coding, the source coding and the hybrid coding. In this paper, First, the reference waveform is detected after searching the pitch period by NAMDF similarity and similarity between the reference waveform and the waveform each pitch period. It made a decision whether the waveform is compressed with the threshold of similarity. If the waveform is compressed only magnitude and pitch information is transmitted into the input of G.723.1 vocoder. Performing through the G.723.1 vocoder, the waveform is restored with the magnitude and pitch information by PSOLA synthesis method. The result of simulation with proposed algorithm has a 31% reduction of bit rate than the standard 5.3kbps G.723.1 ACELP vocoder.

  • PDF

On a Pitch Alteration Technique by Cepstrum Analysis of Flattened Excitation Spectrum (평탄화된 여기 스펙트럼에서 켑스트럼 피치 변경법에 관한 연구)

  • 조왕래
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.159-162
    • /
    • 1998
  • Speech synthesis coding is classified into three categories: waveform coding, source coding and hybrid coding. To obtain the synthetic speech with high quality, the synthesis by waveform coding is desired. However, it is difficult to apply waveform coding to synthesis by syllable or phoneme unit, because it does not divide the speech into excitation and formant component. Thus it is required to alter the excitation in waveform coding for applying waveform coding to synthesis by rule. In this paper we propose a new pitch alteration method that minimizes the spectrum distortion by using the behavior of cepstrum. This method splits the spectrum of speech signal into excitation spectrum and formant spectrum and transforms the excitation spectrum into cepstrum domain. The pitch of excitation cepstrum is altered by zero insertion or zero deletion and the pitch altered spectrum is reconstructed in spectrum domain. As a result of performance test, the average spectrum distortion was below 2.29%.

  • PDF

A Design of Hybrid Type Linear Pulse Motor and Microstep Driver (하이브리드형 선형 펄스 모터와 마이크로스텝 드라이버 설계)

  • Kim, M.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.62-67
    • /
    • 2009
  • In this paper we designed a prototype hybrid type linear pulse motor (HLPM) with single side stator structure for low cost. The measurement system which can get the motor characteristics of the HLPM was suggested. The static and dynamic characteristics of the thrust force are measured analyzed. And the microstep drive method is adopted and tested to the drive of prototype HLPM. The thrust waveform is measured respectively to know the differences of the thrust waveform between the microstep drive method and rectangular wave. From the experimental results, it can be confirmed that the repetitive ripple of the thrust force of the prototype HLPM is reduced by taking the microstep drive method.

  • PDF

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.

Transient Analysis of Hybrid Systems Composed of Lumped Elements and Frequency Dependent Lossy Disributed Interconnects

  • Ichikawa, Satoshi;Shimoda, Tomokazu
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.1096-1099
    • /
    • 2000
  • A method to analyze the high speed inter-connects that are composed of frequency dependent lossy distributed lines is presented. Network modeling of hybrid systems is implemented by using the modified nodal admittance matrix in the Laplace transformation domain. The network response is computed by different two methods. One method Is the asymptotic waveform evaluation (AWE) method and other is numerical Laplace inversion method. The merits and demerits of two methods are discussed by applying to several concrete illustrative networks.

  • PDF

Implement of Blood Pressure Simulator Using Proportional Control Valve and Hybrid Controller (비례제어밸브와 혼합제어기를 이용한 혈압 시뮬레이터의 구현)

  • Lee K. W.;Kim C. H.;Han K. B.;Kim H. J.;Jeon G. R.
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.05a
    • /
    • pp.149-153
    • /
    • 2005
  • In the cardiovascular system, the waveform of the pulsatory blood pressure appears variously due to the cardiac impulse and compliance of blood vessels and arm tissue. We have constructed a blood pressure simulator to investigate effects of mechanical properties of artery walls and tissue on blood pressure measurements. The blood pressure simulator is designed to reproduce wave forms of blood pressure in human arteries. To minimize tracking error, we use a linear control valve, and adapt a hybrid control scheme which consists of a feedback controller and a feedforward controller. Any form of the pressure wave can be reproduced, changing function of the wave form in the computer connected to the simulator for control. From experiments, it has been shown that the simulator reproduces wave forms very well, and that the hybrid scheme adapted is superior to the feedback controller.

  • PDF

On a Pitch Alteration Technique in Time-Frequency Hybrid Domain for High Quality Prosody Control of Speech Signal (고음질 운율조절용 시간-주파수 혼성영역 피치변경법)

  • Lee, Sang-Hyo;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.106-109
    • /
    • 1997
  • In the area of the speech synthesis techniques, the waveform coding methods maintain the intelligibility and naturalness of synthetic speech. In order to apply the waveform coding techniques to synthesis by rule, however, we must be able to alter the pitches for prosody control of synthetic speech. In this paper, we propose a new pitch alteration technique in time-frequency hybrid domain, that compensates phase distortion of the cepstral pitch alteration method with time scaling method in the time domain. This method can remove some phase spectrum distortion which is occurred in conjunction point between the waveforms in continued frames. Also, we can obtain little magnitude spectrum distortion below 1.18% for pitch alteration of 200%.

  • PDF

Blood pressure simulator using hybrid controller (합성제어기를 이용한 혈압 시뮬레이터의 구현)

  • Kim, C.H.;SaGong, G.;Nam, Gi-Gon;Jeon, R.
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.44-51
    • /
    • 2007
  • A hybridized simulator for generating blood pressure waveform is proposed to study the remedy and/or evaluation of the conventional sphygmomanometer utilizing the oscillometric method which is widely applied. The blood pressure of a flowing fluid was controlled for the blood vessel's condition caused by a rhythmical and periodical contraction/relaxation because of the special excitatory and conductive system of the heart. In this study, a hybridized controller composed of the PI feedback controller and the feedforward controller. The inverse dynamics function is proposed to operating the control valve while the pressure is applied in an oil pressure tank. The proposed hybrid simulator reproducing the blood pressure waveform in an artificial blood vessel has kept the control performance consistent over all range. Based on these results, the proposed simulators could be applied to the development and compensation of the non invasive sphygmomanometer type as well as to study the characteristics of the blood pressure and blood vessel.