• Title/Summary/Keyword: Homogeneity Index

Search Result 172, Processing Time 0.029 seconds

Comparing the dosimetric impact of fiducial marker according to density override method : Planning study (양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study)

  • Sung, Doo Young;Park, Seyjoon;Park, Ji Hyun;Park, Yong Chul;Park, Hee Chul;Choi, Byoung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: The application of density override is very important to minimize dose calculation errors by fiducial markers of metal material in proton treatment plan. However, density override with actual material of the fiducial marker could make problem such as inaccurate target contouring and compensator fabrication. Therefore, we perform density override with surrounding material instead of actual material and we intend to evaluate the usefulness of density override with surrounding material of the fiducial marker by analyzing the dose distribution according to the position, material of the fiducial marker and number of beams. Materials and Method: We supposed that the fiducial marker of gold, steel, titanium is located in 1.5, 2.5, 4.0, 6.0 cm from the proton beam's end of range using water phantom. Treatment plans were created by applying density override with the surrounding material and actual material of the fiducial marker. Also, a liver cancer patient who received proton therapy was selected. We located the fiducial marker of gold, steel, titanium in 0, 1.5, 3.5 cm from the proton beam's end of range and the treatment plans were created by same method with water phantom. Homogeneity Index(HI), Conformity Index(CI) and maximum dose of Organ At Risk(OAR) in Planning Target Volume(PTV) as the evaluation index were compared according to the material, position of the fiducial marker and number of beam. Results: The HI value was more decreased when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Especially the HI value was increased when the fiducial marker was located farther from the proton beam's end of the range for a single beam and the fiducial marker's position was closer to isocenter for two or more beams. The CI value was close to 1 and OAR maximum dose was greatly reduced when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Conclusion: Density override with surrounding material can be expected to achieve more precise proton therapy than density override with actual material of the fiducial marker and could increase the dose uniformity and target coverage and reduce the dose to surrounding normal tissues for the small fiducial markers used in clinical practice. Most of all, it is desirable to plan the treatment by avoiding the fiducial marker of metal material as much as possible. However, if the fiducial marker have on the beam path, density override of the surrounding material can be expected to achieve more precise proton therapy.

  • PDF

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • v.34 no.4
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

Effect of Microstructure on Conductivity of W-Cu Composite (W-CU 복합재료의 전도도에 미치는 미세조직의 영향)

  • Lee Young Jung;Park Kwang Hyun;Lee Byung Hoon;Kim Deok-Soo;Kim Young Do
    • Korean Journal of Materials Research
    • /
    • v.15 no.2
    • /
    • pp.85-88
    • /
    • 2005
  • [ $W-15wt.\%$ ] Cu nanocomposite powders are fabricated by ball-milling and subsequent hydrogen-reduction. The compacted parts of $W-15wt.\%Cu$ nanocomposite powders were sintered at $1200^{\circ}C$ for 1 h with various heating rates of 5 and $20^{\circ}C/min$. The homogeneity of the sintered microstructures was evaluated through homogeneity index by the standard deviation of Victor's hardness test. The W-W contiguities were calculated by using Voronoi diagrams. The sintered microstructure with the heating rate of $20^{\circ}C/min$ was more homogeneous and had lower W-W contiguity than that of $5^{\circ}C/min$. The microstructural homogeneity was directly related to the W-W contiguity. Thermal conductivity of the sintered parts with the heating rate of $20^{\circ}C/min$ was higher than that with heating rate of $5^{\circ}C/min$. This phenomenon indicates that the thermal conductivity is affected by the W-W contiguity resulting from the homogeneity of the sintered microstructure.

Quality assessment of high performance concrete using digitized image elements

  • Peng, Sheng-Szu;Wang, Edward H.;Wang, Her-Yung;Chou, Yu-Te
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.409-417
    • /
    • 2012
  • The quality of high performance concrete largely depends on water cement ratio, porosity, material composition and mix methods. The uniformity of color, texture and compressive strengths are quality indicators commonly used to assess the overall characteristics of concrete mixes. The homogeneity and share of coarse aggregates play a key role in concrete quality and must be analyzed in a microscopic point of view. This research studies the quality of high performance concrete by taking drilled cores in both horizontal and vertical directions from a 1.0 $m^3$ specimen. The coarse aggregate, expressed in digitized $100{\times}116$ dpi resolution images are processed based on brightness in colors through commercial software converted into text files. With the image converting to text format, the share of coarse aggregate is quantified leading to a satisfactory assessment of homogeneity - a quality index of high performance concrete. The compressive strengths of concrete and the shares of coarse aggregate of the samples are also compared in this research study to illustrate its correlation in concrete quality. It is concluded that a higher homogeneity of aggregate exists in the vertical plane than that of the horizontal planes of the high performance concrete. In addition, the concrete specimen showing denser particle packing has relatively higher compressive strengths. The research methodology provides an easy-to-use, direct measurement of high performance concrete when conducting quality assessment in the construction site.

Determination of homogeneity index of cementitious composites produced with eps beads by image processing techniques

  • Comak, Bekir;Aykanat, Batuhan;Bideci, Ozlem Salli;Bideci, Alper
    • Computers and Concrete
    • /
    • v.29 no.2
    • /
    • pp.107-115
    • /
    • 2022
  • With the improvements in computer technologies, utilization of image processing techniques has increased in many areas (such as medicine, defence industry, other industries etc.) Many different image processing techniques are used for surface analysis, detection of manufacturing defects, and determination of physical and mechanical characteristics of composite materials. In this study, cementitious composites were obtained by addition of Grounded Granulated Blast-Furnace Slag (GGBFS), Styrene Butadiene polymer (SBR), and Grounded Granulated Blast-Furnace Slag and Styrene Butadiene polymer together (GGBFS+SBR). Expanded Polystyrene (EPS) beads were added to these cementitious composites in different ratios (20%, 40% and 60%). The mechanical and physical characteristics of the composites were determined, and homogeneity indexes of the composites were determined by image processing techniques to determine EPS distribution forms in them. Physical and mechanical characteristics of the produced samples were obtained by applying consistency, density, water absorption, compressive strength (7 and 28 days), flexural strength (7 and 28 days) and tensile splitting strength (7 and 28 days) tests on them. Also, visual examination by using digital microscope, and image analysis by using image processing techniques with open source coded ImageJ program were performed. As a result of the study, it is determined that GGBFS and SBR addition strengthens the adhesion sites formed as it increases the adhesion power of the mixture and helps to get rid of the segregation problem caused by EPS. As a result of the image processing analysis it is demonstrated that GGBFS and SBR addition has positive contribution on homogeneity index.

Interpretability Comparison of Popular Decision Tree Algorithms (대표적인 의사결정나무 알고리즘의 해석력 비교)

  • Hong, Jung-Sik;Hwang, Geun-Seong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.15-23
    • /
    • 2021
  • Most of the open-source decision tree algorithms are based on three splitting criteria (Entropy, Gini Index, and Gain Ratio). Therefore, the advantages and disadvantages of these three popular algorithms need to be studied more thoroughly. Comparisons of the three algorithms were mainly performed with respect to the predictive performance. In this work, we conducted a comparative experiment on the splitting criteria of three decision trees, focusing on their interpretability. Depth, homogeneity, coverage, lift, and stability were used as indicators for measuring interpretability. To measure the stability of decision trees, we present a measure of the stability of the root node and the stability of the dominating rules based on a measure of the similarity of trees. Based on 10 data collected from UCI and Kaggle, we compare the interpretability of DT (Decision Tree) algorithms based on three splitting criteria. The results show that the GR (Gain Ratio) branch-based DT algorithm performs well in terms of lift and homogeneity, while the GINI (Gini Index) and ENT (Entropy) branch-based DT algorithms performs well in terms of coverage. With respect to stability, considering both the similarity of the dominating rule or the similarity of the root node, the DT algorithm according to the ENT splitting criterion shows the best results.

A Comparison Analysis of the Labor Efficiency between Quality-Adjusted Labor and Quality-Unadjusted Labor in Jeju Mandarin Production -Based on the Difference in Market Wages- (농업 노동의 질적 차이를 반영한 감귤 생산 노동투입 효율성 비교 분석 -시장 임금차이를 기준으로-)

  • Lee, Bong-Sil;Yu, Young-bong
    • Journal of Agricultural Extension & Community Development
    • /
    • v.28 no.3
    • /
    • pp.153-165
    • /
    • 2021
  • This study aims to analyze the difference in production elasticity based on the types of agricultural labor input regarding its qualitative difference in Jeju mandarin production. To estimate the production function of qualityadjusted labor, we have set up a Quality-Adjusted Index based on the market wage of the agricultural field. We have conducted a multiple regression analysis of the newly estimated labor inputs using the Ordinary Least Squares regression. Results show that the production efficiency of aggregate total labor hours (quality-unadjusted labor input) is overestimated compared to quality-adjusted labor with qualitative labor homogeneity. Moreover, by analyzing household labor and employment labor, we have observed that the marginal productivity of household labor exceeds that of employment labor. In conclusion, this study verifies that securing labor input homogeneity is crucial for analyzing agricultural labor hours' economic efficiency accurately.

The Usability Evaluation Half Beam Radiation Treatment Technique on the Esophageal Cancer (식도암 환자에서의 Half Beam 치료법의 유용성 평가)

  • Park, Hochoon;Kim, Youngjae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.287-293
    • /
    • 2015
  • Because of esophageal cancer has the long length of the lesion and also inhomogeneous in depth. So, the radiation dose distribution was inhomogeneous in radiation therapy. To overcomes the dose distribution uniformity using half beam method. Patient's CT image was used radiation treatment planning. We used two planning methods that one is the using normal beam and another is using half beam. Than comparing the two radiotherapy planning using target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues - heart, spinal cord, lung -. In results, Treatment planning using half beam is little more than normal beam in target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues covering. However, If the patient is not correct position patients may arise a side effect. Thus, the using in Half beam involving the geometrically exact under lung cancer is considered to advantage.

Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study (토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험)

  • Dae-Gun, Kim;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.857-862
    • /
    • 2022
  • The purpose of this study was to evaluate a three-dimensional conformal radiotherapy (3D-CRT) treatment plan with regard to head tilting in whole-brain radiotherapy (WBRT) using TomoDirect (TD) mode in Tomotherapy. WBRT 3D-CRT by TD was compared for a total of five head tilt angles (-20°, -10°, 0°. +10° and +20°). The dose homogeneity index (HI) and prescription dose index (CI) were calculated to confirm the target coverage. The maximum and average doses for critical organs such as the lens, eyeball and parotid glands were calculated for different angles of head tilting. The HI and CI were closet to the result value of 1 at the head tilted angle +10° and +20°. At a head tilted angle of +10°, the dose to the lens and eyeballs decreased by about 74% and about 30%, when compared with the reference angle (0°), respectively. The results of this study suggest that a head angle of +10 with chin-up would save adequate target coverage and reduce exposure dose to the lens.

Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer (유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가)

  • Kim, Dae-Woong;Kim, Jong-Won;Choi, Yun-Kyeong;Kim, Jung-Soo;Hwang, Jae-Woong;Jeong, Kyeong-Sik;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Purpose: The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. In this paper, we comparing the dose distribution between three dimensional conformal radiation radiotherapy (3D-CRT) and helical tomotherapy (TOMO) plan for partial breast cancer. Materials and Methods: Twenty patients were included in the study, and plans for two techniques were developed for each patient (left breast:10 patients, right breast:10 patients). For each patient 3D-CRT planning was using pinnacle planning system, inverse plan was made using Tomotherapy Hi-Art system and using the same targets and optimization goals. We comparing the Homogeneity index (HI), Conformity index (CI) and sparing of the organs at risk for dose-volume histogram. Results: Whereas the HI, CI of TOMO was significantly better than the other, 3D-CRT was observed to have significantly poorer HI, CI. The percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose was 3D-CRT (mean: 40.4%), TOMO (mean: 18.3%). The average ipsilateral lung volume percentage receiving 20% of the PD was 3D-CRT (mean: 4.8%), TOMO (mean: 14.2), concerning the average heart volume receiving 20% and 10% of the PD during treatment of left breast cancer 3D-CRT (mean: 1.6%, 3.0%), TOMO (mean: 9.7%, 26.3%) Conclusion: In summary, 3D-CRT and TOMO techniques were found to have acceptable PTV coverage in our study. However, in TOMO, high conformity to the PTV and effective breast tissue sparing was achieved at the expense of considerable dose exposure to the lung and heart.

  • PDF