• 제목/요약/키워드: High-efficient power

검색결과 1,324건 처리시간 0.045초

높은 전력밀도를 갖는 500 kHz 고주파 LLC 컨버터의 설계와 구현 (Design and Implementation of 500 kHz High Frequency LLC Resonant Converter for High Power Density)

  • 박화평;정지훈
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.51-58
    • /
    • 2015
  • In order to decrease the size of a switch mode power supply, high switching frequency can be an efficient way to reduce the size of passive components in the converter. In this paper, a 500-kHz high-frequency LLC resonant converter is proposed with an accurate design method of magnetizing inductance, as well as the relationship between the switching frequency and the size of the passive components. Simulation and experimental results are presented to verify the proposed methods and equations, including the temperature data of each passive and active device of the converter. Using those results, dominant power losses in the prototype converter under 500-kHz high-frequency operation are investigated, compared with the results from a 100-kHz converter. In addition, operating waveforms and power conversion efficiency will be shown to obtain design considerations for the high switching frequency LLC resonant converter.

고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구 (A Study on Parallel Operation of PWM Converter for Auxiliary bloc High Speed Train)

  • 송상훈;성재원;김연충;원충연;최종묵;기상우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.358-361
    • /
    • 1999
  • In auxiliary block of high speed train power factor correction and harmonics reduction is very important issue for efficient energy transport. The GTO-equipped PWM converter is used for traction untill resently. But the rising power capability of IGBTs resently allows to build IGBT-equipped PWM converter with a considerably increased switching frequency. This paper presents switching pattern, control method, operation mode and tuned filter to reduce dc link voltage ripple for paralleled converter.

  • PDF

고역률 LED 구동회로의 효율화에 관한 연구 (A Study on the Efficiency of a High Power Factor LED Driver Circuit)

  • 이동원;김병철
    • 한국전기전자재료학회논문지
    • /
    • 제26권8호
    • /
    • pp.629-634
    • /
    • 2013
  • The rectified voltage supplied to LED lamp is used in load and then the surplus voltage can be produced in LED lighting. In this case, LED lighting is proposed that can recyclable the excess voltage to supply power to the controller.

전원설비 저감을 위한 고효율 전력변환기술 개발 (A Development of Efficient Power Conversion Technology for Reduction of Power Equipment)

  • 구명완;이우원;임계영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.142-144
    • /
    • 2008
  • The Former High Efficiency Inverter(the power restoration process) system process has advantage which is the energy reduction rather than the Former Inverter(the resistence damping process), However, under repair and remodeling, the power facilities capacity is not easy to increase that the former High Efficiency Inverter needs to increase the Power Facilities Capacity of 20~30% than the Inverter(the resistence damping process) so Therefore we are going to suggest the system which is not going to make an increase the power facilities capacity and is applicable the High Efficiency Inverter.

  • PDF

SoC환경에서의 저전력 테스트를 고려한 테스트 패턴 압축에 대한 효율적인 알고리즘 (A new efficient algorithm for test pattern compression considering low power test in SoC)

  • 신용승;강성호
    • 대한전자공학회논문지SD
    • /
    • 제41권9호
    • /
    • pp.85-95
    • /
    • 2004
  • 최근 반도체 칩의 집적도가 올라가고 System-on-Chip(Soc)환경이 보편화되면서 Automatic Test Equipment(ATE)를 이용한 테스트 수행시 테스트 패턴의 크기 문제와 스캔체인에서의 전력 소모문제가 크게 부각되고 있다. 또한, 테스트 패턴 크기문제를 해결하기 위해 테스트 패턴을 압축하게 되면 테스트 패턴의 소모하는 전력량이 커지게 되어 저전력 테스트를 수행하는데 어려움이 있어 두 가지 문제를 해결할 수 없었다 본 논문에서는 이러한 문제점들을 동시에 해결하기 위해서 Run-length code를 기반으로 하여 저전력 테스트가 가능하면서 테스트 패턴의 크기도 줄일 수 있는 알고리즘을 제안하였다. 본 논문에서는 기존에 제시되었던 알고리즘과 비교ㆍ분석하는 실험을 통하여 이 알고리즘의 효율성을 보여주고 있다.

환경경영에서 건강신념모델을 이용한 병원환경이 대응성과 건강가치성을 통해 예방행동에 미치는 영향 (Effects of hospital environment using health belief model in environmental management on preventive behaviors through responsiveness and health value)

  • 장국현;황찬규;송영우
    • 디지털산업정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.231-257
    • /
    • 2016
  • Several efforts to replace the use of existing fossil energy resources have already been made around the world. As a result, a new industry of renewable energy has been created, and efficient energy distribution and storage has been promoted intensively. Among the newly explored renewable energy sources, the most widely used one is solar energy generation, which has a high market potential. An energy storage system (ESS) is a system as required. In this paper, the design and implementation of an ESS for the efficient use of power in stand-alone street lights is presented. In current ESS applied to stand-alone street lights, either 12V~24V DC (from solar power) or 110V~220V AC (from commercial power) is used to recharge power in systems with lithium batteries. In this study, an ESS that can support both solar power and commercial power was designed and implemented; it can also perform emergency recharge of portable devices from solar powered street lights. This system can maximize the scalability of ESSes using lithium batteries with efficient energy conversion, with the advantage of being an eco-friendly technology. In a ripple effect, it can also be applied to smart grids, electric vehicles, and new, renewable storage markets where energy storage technology is required.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

A new moving-mesh Finite Volume Method for the efficient solution of two-dimensional neutron diffusion equation using gradient variations of reactor power

  • Vagheian, Mehran;Ochbelagh, Dariush Rezaei;Gharib, Morteza
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1181-1194
    • /
    • 2019
  • A new moving-mesh Finite Volume Method (FVM) for the efficient solution of the two-dimensional neutron diffusion equation is introduced. Many other moving-mesh methods developed to solve the neutron diffusion problems use a relatively large number of sophisticated mathematical equations, and so suffer from a significant complexity of mathematical calculations. In this study, the proposed method is formulated based on simple mathematical algebraic equations that enable an efficient mesh movement and CV deformation for using in practical nuclear reactor applications. Accordingly, a computational framework relying on a new moving-mesh FVM is introduced to efficiently distribute the meshes and deform the CVs in regions with high gradient variations of reactor power. These regions of interest are very important in the neutronic assessment of the nuclear reactors and accordingly, a higher accuracy of the power densities is required to be obtained. The accuracy, execution time and finally visual comparison of the proposed method comprehensively investigated and discussed for three different benchmark problems. The results all indicated a higher accuracy of the proposed method in comparison with the conventional fixed-mesh FVM.

고효율 가변 전력 LED조명기기 Driver 개발 (A Study of Designing of Energy Efficient LED Driver Apparatus)

  • 유수엽;엄기홍;김형준
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.28-31
    • /
    • 2009
  • This paper is a report of designing for high efficient LED lights driver. The main purpose of driver designing is meet the requirement the high efficient energy regulation for light of Korea. To meet the regulation the high efficient the circuit adapted wide range resonant power supply and current regulate circuit to adjust LED current. This product archived excellent performance as well as reliable operation.

  • PDF

A Highly Efficient Dual-Mode 3G/4G Linear CMOS Stacked-FET Power Amplifier Using Active-Bypass

  • Kim, Unha;Kim, Yong-Gwan;Woo, Jung-Lin;Park, Sunghwan;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.393-398
    • /
    • 2014
  • A highly efficient dual-mode linear CMOS stacked-FET power amplifier (PA) is implemented for 3G UMTS and 4G LTE handset applications. High efficiency is achieved at a backed-off output power ($P_{out}$) below 12 dBm by employing an active-bypass amplifier, which consumes very low quiescent current and has high load-impedance. The output paths between high- and low-power modes of the PA are effectively isolated by using a bypass switch, thus no RF performance degradation occurs at high-power mode operation. The fabricated 900 MHz CMOS PA using a silicon-on-insulator (SOI) CMOS process operates with an idle current of 5.5 mA and shows power-added efficiency (PAE) of 20.5%/43.5% at $P_{out}$ = 12.4 / 28.2 dBm while maintaining an adjacent channel leakage ratio (ACLR) better than -39 dBc, using the 3GPP uplink W-CDMA signal. The PA also exhibits PAE of 35.1% and $ACLR_{E-UTRA}$ of -33 dBc at $P_{out}$ = 26.5 dBm, using the 20 MHz bandwidth 16-QAM LTE signal.