• Title/Summary/Keyword: High-Dose

Search Result 4,233, Processing Time 0.036 seconds

Prediction of nonresponsiveness to mediumdose intravenous immunoglobulin (1 g/kg) treatment: an effective and safe schedule of acute treatment for Kawasaki disease

  • Moon, Kyung Pil;Kim, Beom Joon;Lee, Kyu Jin;Oh, Jin Hee;Han, Ji Whan;Lee, Kyung Yil;Lee, Soon Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.4
    • /
    • pp.178-182
    • /
    • 2016
  • Purpose: Medium-dose (1 g/kg) intravenous immunoglobulin (IVIG) is effective in the majority of patients with Kawasaki disease (KD) but some patients who do not respond to medium-dose IVIG are at high risk for the development of coronary artery lesions (CALs). The purpose of this study was to identify the clinical predictors associated with unresponsiveness to medium-dose IVIG and the development of CALs. Methods: A retrospective study was performed in 91 children with KD who were treated with mediumdose IVIG at our institution from January 2004 to December 2013. We classified the patients into responders (group 1; n=68) and nonresponders (group 2; n=23). We compared demographic, laboratory, and echocardiographic data between the 2 groups. Results: Multivariate logistic regression analysis identified 6 variables as predictors for resistance to medium-dose IVIG. We generated a predictive scoring system assigning 1 point each for percentage of neutrophils ${\geq}65%$, C-reactive protein ${\geq}100mg/L$, aspartate aminotransferase ${\geq}100IU/L$, and alanine aminotransferase ${\geq}100IU/L$, as well as 2 points for less than 5 days of illness, and serum sodium level ${\leq}136mmol/L$. Using a cutoff point of ${\geq}4$ with this scoring system, we could predict nonresponsiveness to medium-dose IVIG with 74% sensitivity and 71% specificity. Conclusion: If a patient has a low-risk score in this system, medium-dose IVIG can be recommended as the initial treatment. Through this process, we can minimize the adverse effects of high-dose IVIG and incidence of CALs.

General Radiography Usage and Exposure Dose of Korean Elderly: Based on Data from Aged Patients in 2016 (한국 노인의 일반촬영 이용량 및 피폭선량: 2016년 고령환자데이터 기반)

  • Gil, Jong-Won;Yoo, Se-Jong;Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.495-502
    • /
    • 2021
  • This study aims to provide basic data for elderly health insurance policy and medical radiation safety management by analyzing the general radiography usage and exposure dose of the elderly in Korea. The effective dose for each general radiography was calculated using the ALARA-GR program for 260 general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2016 elderly patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was applied. The general radiography usage and exposure dose per person aged 65 years and over was 6.47 cases and 0.56 mSv. Females showed higher value than males as 7.15 cases and 0.66 mSv(p<.001). By age, those between 75 and 79 showed the highest number as 6.97 cases and 0.62 mSv(p<.001). Those who were supported by Medical Aid showed higher value than those who were insured by National Health Insurance as 8.82 cases and 0.76 mSv(p<.001). In addition, the ratio by radiography was in the order of Chest 20.85%, Knee Joint 15.58%, and L-spine 14.67%, and the exposure dose was L-spine 29.40%, Chest 15.82%, Abdomen 7.97%, and Entire Spine 7.20%. General radiography, which is widely used due to the high frequency of diseases in the elderly population should be taken into consideration when establishing health insurance policies. In addition, it is necessary to check whether the general radiography with high exposure dose is performed as a routine examination without considering medical necessity.

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator

  • Kwon, Na Hye;Jang, Young Jae;Kim, Jinsung;Kim, Kum Bae;Yoo, Jaeryong;Ahn, So Hyun;Kim, Dong Wook;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.145-152
    • /
    • 2021
  • Purpose: During the treatments of cancer patients with a linear accelerator (LINAC) using photon beams with energies ≥8 MV, the components inside the LINAC head get activated through the interaction of photonuclear reaction (γ, n) and neutron capture (n, γ). We used spectroscopy and measured the dose rate for the LINAC in operation after the treatment ended. Methods: We performed spectroscopy and dose rate measurements for three units of LINACs with a portable high-purity Germanium (HPGe) detector and a survey meter. The spectra were obtained after the beams were turned off. Spectroscopy was conducted for 3,600 seconds, and the dose rate was measured three times. We identified the radionuclides for each LINAC. Results: According to gamma spectroscopy results, most of the nuclides were short-lived radionuclides with half-lives of 100 days, except for 60Co, 65Zn, and 181W nuclides. The dose rate for three LINACs obtained immediately in front of the crosshair was in the range of 0.113 to 0.129 µSv/h. The maximum and minimum dose rates measured on weekends were 0.097 µSv/h and 0.092 µSv/h, respectively. Compared with the differences in weekday data, there was no significant difference between the data measured on Saturday and Sunday. Conclusions: Most of the detected radionuclides had half-lives <100 days, and the dose rate decreased rapidly. For equipment that primarily used energies ≤10 MV, when the equipment was transferred after at least 10 minutes after shutting it down, it is expected that there will be little effect on the workers' exposure.

The Dielectric Properties due to the Temperature and Applied Voltage of Oriented Polypropylene Film Irradiated by $^{60}/Co-${\gamma}$$ ($^{60}/Co-${\gamma}$$선으로 조사된 이축연신 폴리프로필렌 필림의 온도 및 전압에 따른 유전특성)

  • 홍진웅;이수원;김왕곤
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 1994
  • In this paper, It is studied that the variation of the dielectric absorption of the specimen according to the change with $^{60}$ Co-${\gamma}$ ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiated oriented polypropylene film, we have observed dielectric properties within the temporature range of 30~130 ($^{\circ}C$) and voltage range of 100~250 (V). As for the dependency of temperature by tan $\delta$, the $\alpha$ peak which appears at high temperature increases accordingly to the increment of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The $\beta$ peak which appears the orientation by dipoles and molecular motions in the amorphous region at low temperature. For the dependency of voltage by tan $\delta$ at low temperature, the peak of the tan $\delta$ shifts accordingly to the increment of irradiation dose towards the high temperature region.

  • PDF

A Case of Intractable Hiccups Associated with High Dose Intravenous Methylprednisolone in a Patient with Third Nerve Palsy (동안신경마비 환자에서 고용량 메칠프레드니솔론 정주 후 발생한 난치성 딸꾹질 1예)

  • Na, Sang-Jun;Yum, Kyu Sun;Lee, Kee Ook
    • Annals of Clinical Neurophysiology
    • /
    • v.10 no.1
    • /
    • pp.79-82
    • /
    • 2008
  • The etiology of intractable hiccups is most commonly idiopathic. However, they are occasionally associated with some underlying disorders including gastro-esophageal reflux disease. There are a few previous reports describing the association of intractable hiccups with high dose corticosteroid. We experienced an unusual case of intractable hiccups following a high dose intravenous methylprednisolone therapy in a patient with right third nerve palsy. Since methylprednisolone is commonly used in various neurological problems, physicians should be aware of its possible side effect including intractable hiccups.

  • PDF

Nutritional strategy of early amino acid administration in very low birth weight infants

  • Lee, Byong Sop
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.3
    • /
    • pp.77-83
    • /
    • 2015
  • Relative to a fetus of the same gestational age, very low birth weight (VLBW) infants are more likely to be underfed and to undergo growth restriction during their early hospital stay. The current trend towards "early and aggressive" nutritional strategies in VLBW infants aims to overcome the early nutritional deficiency and thereby boost postnatal catch-up growth, simultaneously improving long-term neurodevelopmental outcomes. Although the minimum starting amino acid (AA) dose to prevent negative nitrogen balance is well established, the upper limit and the rate of increase of early AA doses are controversial. Most randomized controlled trials show that early and high-dose (target, 3.5 to 4.9 g/kg/day) AA regimens, with or without high nonprotein calories, do not improve long-term growth and neurodevelopment. High-dose AA supplementation may lead to early metabolic disturbances and excessive or disproportionate plasma AA levels, particularly in infants of very low gestational age. Further large studies are needed to clarify the optimal strategy for early administration of parenteral AA doses in VLBW infants.

Gene Expression Profiles Following High-Dose Exposure to Gamma Radiation in Salmonella enterica serovar Typhimurium

  • Lim, Sangyong;Jung, Sunwook;Joe, Minho;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.2 no.3
    • /
    • pp.111-119
    • /
    • 2008
  • Microarrays can measure the expression of thousands of genes to identify the changes in expression between different biological states. To survey the change of whole Salmonella genes after a relatively high dose of gamma radiation (1 kGy), transcriptome dynamics were examined in the cells by using DNA microarrays. At least 75 genes were induced and 89 genes were reduced two-fold or more after irradiation. Several genes located in pSLT plasmid, cyo operon, and Gifsy prophage were induced along with many genes encoding uncharacterized proteins.While, the expression of genes involved in the virulence of Salmonella as well as metabolic functions were decreased. Although the radiation response as a whole could not be illustrated by using DNA microarrays, the data suggest that the response to high dose of irradiation might be more complex than the SOS response.

Simulation and Measurement of Thermal Ablation in a Tissue-Mimicking Phantom and Ex-Vivo Porcine Liver by Using High Intensity Focused Ultrasound

  • Lee, Kang Il
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1289-1294
    • /
    • 2018
  • The present study aims to investigate experimentally and theoretically thermal ablation in soft tissues by using high intensity focused ultrasound (HIFU) to assess tissue damage during HIFU thermotherapy. The HIFU field was calculated by solving the axisymmetric Khokhlov-Zabolotskaya-Kuznetsov equation from the frequency-domain perspective. The temperature field was calculated by solving Pennes' bioheat transfer equation, and the thermal dose required to create a thermal lesion was calculated by using the thermal dose formula based on the thermal dose of a 240-min exposure at $43^{\circ}C$. In order to validate the simulation results, we performed thermal ablation experiments in a tissue-mimicking phantom and ex-vivo porcine liver for two different HIFU source conditions by using a 1.1-MHz, single-element, spherically focused HIFU transducer. The small difference between the measured and the predicted lesion sizes suggests that the implementation of the numerical model used here should be modified to iteratively allow for temperature-dependent changes in the physical properties of tissues.

Treatment of high-risk neuroblastoma

  • Sung, Ki-Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.4
    • /
    • pp.115-120
    • /
    • 2012
  • Although high-dose chemotherapy and autologous stem cell transplantation (HDCT/autoSCT) have improved the prognosis for patients with high-risk neuroblastoma (NB), event-free survival rates remain in the range of 30 to 40%, which is unsatisfactory. To further improve outcomes, several clinical trials, including tandem HDCT/autoSCT, high-dose $^{131}I$-metaiodobenzylguanidine treatment, and immunotherapy with NB specific antibody, have been undertaken and pilot studies have reported encouraging results. Nonetheless, about half of high-risk NB patients still experience treatment failure and have no realistic chance for cure with conventional treatment options alone after relapse. Therefore, a new modality of treatment is warranted for these patients. In recent years, several groups of investigators have examined the feasibility and effectiveness of reduced-intensity allogeneic stem cell transplantation (RI alloSCT) for the treatment of relapsed/progressed NB. Although a graft-versus-tumor effect has not yet been convincingly demonstrated in the setting of relapsed NB, the strategy of employing RI alloSCT has provided hope that treatment-related mortality will be reduced and a therapeutic benefit will emerge. However, alloSCT for NB is still investigational and there remain many issues to be elucidated in many areas. At present, alloSCT is reserved for specific clinical trials testing the immunomodulatory effect against NB.