• Title/Summary/Keyword: High voltage pulse current

Search Result 420, Processing Time 0.031 seconds

A New Generation of Biocompatible Pulse-discharged Plasma by Marx Generator and Its Application on the Biomolecules

  • Park, Ji-Hun;Attri, Pankaj;Hong, Yeong-Jun;Kumar, Naresh;Kim, Sang-Yeop;Kim, Yeong-Jo;Lee, Gu-Hyeop;Lee, Seung-Mok;Park, Bong-Sang;Jeon, Su-Nam;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.240.2-240.2
    • /
    • 2014
  • Characteristics of pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is $0.5{\mu}F$ to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of $0.5{\mu}F$. The high voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ${\sim}1{\mu}s$ between the two electrodes of anode-cathode made of stainless steel, which are immersed into the liquids. For the investigation of the influence of pulsed plasma on biomolcules, we have focused on the amino acids, DNA, proteins, cell and cholesterol.

  • PDF

Interleaved ZVS DC/DC Converter with Balanced Input Capacitor Voltages for High-voltage Applications

  • Lin, Bor-Ren;Chiang, Huann-Keng;Wang, Shang-Lun
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.661-670
    • /
    • 2014
  • A new DC/DC converter with zero voltage switching is proposed for applications with high input voltage and high load current. The proposed converter has two circuit modules that share load current and power rating. Interleaved pulse-width modulation (PWM) is adopted to generate switch control signals. Thus, ripple currents are reduced at the input and output sides. For high-voltage applications, each circuit module includes two half-bridge legs that are connected in series to reduce switch voltage rating to $V_{in}/2$. These legs are controlled with the use of asymmetric PWM. To reduce the current rating of rectifier diodes and share load current for high-load-current applications, two center-tapped rectifiers are adopted in each circuit module. The primary windings of two transformers are connected in series at the high voltage side to balance output inductor currents. Two series capacitors are adopted at the AC terminals of the two half-bridge legs to balance the two input capacitor voltages. The resonant behavior of the inductance and capacitance at the transition interval enable MOSFETs to be switched on under zero voltage switching. The circuit configuration, system characteristics, and design are discussed in detail. Experiments based on a laboratory prototype are conducted to verify the effectiveness of the proposed converter.

TreatmentWD Pulse Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Jun-Il;Lee, Sun-Min;Bo, Gak-Hwang;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.36-41
    • /
    • 2012
  • The transcranial magnetic stimulation recharges the energy storing condenser, and sends the stored energy in the condenser to the pulse shaping circuit, which then delivers it to the stimulating coil. The previous types of transcranial magnetic stimulation required a booster transformer, secondary rectifier for high voltages and a condenser for smooth type. The energy storing condenser is recharged by switching the high-voltage direct current power. Loss occurs due to the resistance in the recharging circuit, and the single-pulse output energy in the transcranial magnetic stimulation can be changed because the recharging voltage cannot be adjusted. In this study a booster transformer, which decreases the volume and weight, was not used. Instead, a current resonance inverter was applied to cut down the switching loss. A transcranial magnetic stimulation, which can simultaneously alter the recharging voltage and pulse repeats, was used to examine the output characteristics.

A novel resonant pulse control in resonant DC link inverter (공진형 직류 링크 인버터의 공진 펄스 제어기)

  • 유동욱;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF

The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun (전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계)

  • Kim, Jong-Soo;Jin, Y.S.;Lee, H.S.;Rim, Geun-Hie;Kim, J.S.
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

An Electrical Repair Circuit for Yield Increment of High Density Memory (고집적 메모리의 yield 개선을 위한 전기적 구제회로)

  • 김필중;김종빈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.273-279
    • /
    • 2000
  • Electrical repair method which has replaced laser repair method can replace defective cell by redundancy’s in the redundancy scheme of conventional high density memory. This electrical repair circuit consists of the antifuse program/read/latch circuits, a clock generator a negative voltage generator a power-up pulse circuit a special address mux and etc. The measured program voltage of made antifuses was 7.2~7.5V and the resistance of programmed antifuses was below 500 Ω. The period of clock generator was about 30 ns. The output voltage of a negative voltage generator was about 4.3 V and the current capacity was maximum 825 $mutextrm{A}$. An antifuse was programmed using by the electric potential difference between supply-voltage (3.3 V) and output voltage generator. The output pulse width of a power-up pulse circuit was 30 ns ~ 1$mutextrm{s}$ with the variation of power-up time. The programmed antifuse resistance required below 44 ㏀ from the simulation of antifuse program/read/latch circuit. Therefore the electrical repair circuit behaved safely and the yield of high densitymemory will be increased by using the circuit.

  • PDF

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

A Study on Destruction Characteristics of BJT (Bipolar Junction Transistor) at Different Pulse Repetition Rate (다양한 펄스 반복률에서의 NPN BJT (Bipolar Junction Transistor)의 파괴 특성에 관한 연구)

  • Bang, Jeong-Ju;Huh, Chang-Su;Lee, Jong-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • This paper examines the destruction behavior of NPN BJT (bipolar junction transistor) by repetition pulse. The injected pulse has a rise time of 1 ns and the maximum peak voltage of 2 kV. Pulse was injected into the base of transistor. Transistor was destroyed, current flows even when the base power is turned off. Cause the destruction of the transistor is damaged by heat. Breakdown voltage of the transistor is 975 V at single pulse, and repetition pulse is 525~575 V. Pulse repetition rate increases, the DT (destruction threshold) is reduced. Pulse Repetition rate is high, level of transistor destruction is more serious.

Start-Up Current Control Method for Three-Phase PWM Rectifiers with a Low Initial DC-Link Voltage

  • Gu, Bon-Gwan;Choi, Jun-Hyuk;Jung, In-Soung
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.587-594
    • /
    • 2012
  • When a PWM rectifier has a low DC-link voltage during startup, the output voltage vector cannot be high enough to regulate the input current. This lack of a PWM rectifier output voltage vector can cause an unregulated inrush current when the rectifier operation starts. This paper presents a PWM rectifier start-up current control algorithm for when it starts operation with a lower DC-link voltage than unloaded condition case. To avoid the unregulated inrush current caused by a lack of DC-link voltage, the proposed control scheme regulates the one phase current with one switch chopping and it generates the current command considering the uncontrolled current magnitude information, which is calculated in advance. Simulation and experiment results support the validity of the proposed method.

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF