• Title/Summary/Keyword: High force

Search Result 5,589, Processing Time 0.039 seconds

Development of Adhesion Force Measurement Apparatus with High Stiffness and High Resolution (고탄성 고분해능을 갖는 응착력 측정장치의 개발)

  • Kim, Gyu-Sung;Yoon, Jun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.3 s.192
    • /
    • pp.140-146
    • /
    • 2007
  • To understand adhesive phenomena, we need to get force curve between two surfaces. And it is said that high stiffness force analysis system is needed to get precise force curve and more information of the surfaces. Usually the stiffness of the force measurement system is under the order of 10N/m. The stiffer force measurement system, however, results in more information on the surface, because higher stiffness lead to the wider range of force curves, secondly because the force curve obtained through the stiffer one describes more precise relationship between relative tip-sample separation and interaction force. In this paper, considering for stiffness and resolution, the cantilever was designed and we made adhesion force measurement apparatus with high stiffness and high resolution, so we measured adhesive force between Ag-ball and wafer.

A Study on the Measurement of Contact Force of Pantograph of Korean High Speed Train (한국형 고속전철 집전장치 접촉력 계측에 관한 연구)

  • Seo, Sung-Il;Cho, Yong-Hyun;Park, Choon-Soo;Mok, Jin-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1453-1457
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed by home-grown technology. In this study, a system to measure the contact force of pantograph is developed and installed on the prototype high speed train, Contact force prevents the pantograph from separating from the catenary. However, excessive contact force causes rapid erosion of catenary. The contact force can be divided into lift force and spring force. Contact force measurement is conducted while the train runs on the test track. The lift force is measured by the load cell on the roof separately and combined with the spring force of pan-head to form the contact force. Measured results show that the contact force of the pantograph of Korean High Speed Train is below the upper limit regulated by the high speed train standards. The contact force measuring system provides data to evaluate safety of the catenary system.

  • PDF

A Study on the Evaluation on High-speed Machining Characteristics of AL7075 (AL7075의 고속가공특성 평가)

  • 이종현;이동주;이응숙;신보성
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.220-224
    • /
    • 2001
  • High-speed machining is one of the most effective technologies to improve productivity. Because of the high speed and high feedrate, high-speed machining can give great advantages for the machining of dies and molds. To perform efficient high-speed machining, evaluation of high speed machinability must be studied preferentially and it can be identified by investigation of cutting force. To measure cutting force in high-speed machining, dynamometer has to have high natural frequency. In this paper, The dynamometer which has high natural frequency used to measure the cutting force in various cutting conditions. High-speed machining characteristics are evaluated by the cutting force, FFT analysis of the cutting force and chip formation.

  • PDF

Analysis of Biomechanical Characteristics of Therapist's Ground Reaction and Contact Hand Force and Time According to Table Height During Spinal Manipulation

  • Jejeong Lee;Yongwoo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.2
    • /
    • pp.130-139
    • /
    • 2023
  • Objective: This study aimed to analyze the effects and characteristics of the height of the treatment table on the force and time of ground reaction (GR) and contact hand (CH) generated from the therapist's feet to generate thrust during spinal manipulation (SM). Design: A cross-sectional survey study Methods: Thirty-six healthy subjects were recruited. SM was performed on the ilium using a knee-high table, where the therapist felt it was easy to control the subject's posture and body shape and comfortable to generate force, as well as a relatively high thigh-high table. The force and time generated by the therapist's GR and CH were simultaneously measured through a force plate. Results: As a result, there was a significant difference in peak force and rundown force at the therapist's GR according to the table height (p < 0.05). In the therapist's CH, there was a significant difference between PreMin (preload minimum) force and peak force (p < 0.05), and there was a significant difference between the time from PreMin to peak and the time of the entire section (p < 0.05). Conclusions: As a result, the generation of increased CH force and faster thrust duration were confirmed by mobilizing the reduced GR force of the therapist to generate thrust than the relatively high table on the knee-high table.

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

Development of 3-Component tool Dynamometer for Evaluation of Machinability in High Speed Machining (고속가공에서 가공성 평가를 위한 3축 공구동력계 개발)

  • Kang, Myeong-Chang;Kim, Jeong-Suk;Lee, Deuk-Woo;Lee, Ki-Yong;Kim, Jeong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.5 s.98
    • /
    • pp.11-18
    • /
    • 1999
  • Recently high speed machining is being studied actively to reduce machining time and to improve machining precision. To perform efficient high speed machining, evaluation of high speed machinability must be studied preferentially and it can be identified by investigation of cutting force. To measure cutting forces in high speed machining, dynamometer which has high natural frequency was newly designed using 3-axes piezo force sensor. For newly designed dynamometer, calibration is conducted with sensitivity of force sensor modulated and proper preload and interference force are investigated experimently. Also, cutting force signals of newly designed dynamometer are compared with those of conventional one in high speed cutting experiment and its superiority is confirmed. Then using newly designed dynamometer, high speed machinability is evaluated about cutting force and tool wear in various cutting conditions.

  • PDF

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo, Sung-Il;Cho, Yong-Hyun;Mok, Jin-Yong;Park, Choon-Soo;Kim, Ki-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1374-1378
    • /
    • 2005
  • Appropriate upward force is crucial for the pantograph on high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the arms of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measurement system was developed. The forces acting on the pantograph were clarified and a procedure to calculate the aerodynamic lifting force was proposed. A special device was invented and applied to measure the lifting force. Measured contact forces were displayed by the developed system and evaluated according to the criteria. Countermeasures were also taken to reduce the contact force based on the results.

  • PDF

Modelling the multi-physics of wind-blown sand impacts on high-speed train

  • Zhang, Yani;Jiang, Chen;Zhan, Xuhe
    • Wind and Structures
    • /
    • v.32 no.5
    • /
    • pp.487-499
    • /
    • 2021
  • The wind-blown sand effect on the high-speed train is investigated. Unsteady RANS equation and the SST k-ω turbulent model coupled with the discrete phase model (DPM) are utilized to simulate the two-phase of air-sand. Sand impact force is calculated based on the Hertzian impact theory. The different cases, including various wind velocity, train speed, sand particle diameter, were simulated. The train's flow field characteristics and the sand impact force were analyzed. The results show that the sand environment makes the pressure increase under different wind velocity and train speed situations. Sand impact force increases with the increasing train speed and sand particle diameter under the same particle mass flow rate. The train aerodynamic force connected with sand impact force when the train running in the wind-sand environment were compared with the aerodynamic force when the train running in the pure wind environment. The results show that the head car longitudinal force increase with wind speed increasing. When the crosswind speed is larger than 35m/s, the effect of the wind- sand environment on the train increases obviously. The longitudinal force of head car increases 23% and lateral force of tail increases 12% comparing to the pure wind environment. The sand concentration in air is the most important factor which influences the sand impact force on the train.

Dynamic Analysis and Experiments of High Impulsive Force Device with Isolation System (완충시스템을 장착한 고충격 발생기구의 동특성 해석 및 실험)

  • Park, Moon-Sun;Kang, Tae-Ho;Byun, Young-Seop;Song, Joon-Beom;Ku, Tae-Wan;Kang, Beom-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.107-114
    • /
    • 2008
  • The aim of this study is to obtain the useful design guideline for high impulsive force device with an isolation system by the analytic approach of dynamics characteristics. In this study, the high impulsive force system was modeled and analyzed in view of multi-body dynamics, and verified the modeling and analysis result by the experiment of the high impulsive force device. Additionally, the dynamic analysis was performed for the isolation system with the selected coefficients of elastic spring and damper selected. Experimental result for the high impulsive force device with the isolation system was compared and analyzed. From the result, it was confirmed that the design guideline for the isolation system of the high impulsive force device was useful.

VCB Control Algorithm Verifications of Korean High Speed Train (한국형 고속전철의 VCB 제어 알고리즘 검증)

  • Jeon, J.W.;Jeong, P.K.;Lee, J.H.;Park, D.Y.;Kim, Y.J.;Lee, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1362-1364
    • /
    • 2000
  • This paper presents the control algorithm verification process for VCB (Vacuum Circuit Breaker) of Korean High Speed Train. In order to enhance the reliability of the control algorithm, the verification process must be performed. The verification is conducted by comparing the pre-designed control algorithm with the pre-planned scenario by simulation tools such as SDL and MSC. This verification process will be applied to the other control algorithms of various control units of Korean High Speed Train.

  • PDF