• Title/Summary/Keyword: High efficient control

Search Result 1,305, Processing Time 0.028 seconds

Improvement method for Charging Speed of high voltage Capacitor with Microprocessor (마이크로프로세서를 이용한 고압전원용 커패시터의 충전 속도 향상)

  • Kim, Cherl-Jin;Hong, Sung-Ho;Lee, Soo-Rang;Kim, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.197-199
    • /
    • 2006
  • This paper proposes the method to improve the charging speed of high voltage capacitor used in the medical device with high voltage. Feedback control method with microprocessor was used to detect and control the charging voltage. The result shows that the proposed method is more efficient than the previous converting method with typical PWM IC.

  • PDF

Structual Design of a Building with High Damping Provided by Deformation Amplification Mechanisms and Tuned Viscous Mass Damper

  • Mizuki Shigematsu;Takaaki Udagawa;Satoru Nagase
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.215-224
    • /
    • 2023
  • This paper presents the structural design and response control system of the JR MEGURO MARC building, a 70 meters high office building with steel structure located in Tokyo (Figure 1). In order to achieve high earthquake resistance and useable office space, this building integrates a centralized response control system with deformation amplification mechanisms and tuned viscous mass dampers on the lower floor. Moreover, buckling-restrained braces (BRB) are installed on the upper floors to increase the effectiveness of centralized response control system and to reduce damage of the main frames in the event of a major earthquake. It features an efficient centralized response control system by amplifying the deformation of the dampers without creating a soft story.

Effect of Radiation Heat Transfer on the Control of Temperature Gradient in the Induction Heating Furnace for Growing Single Crystals (전자기 유도가열식 단결정 성장로의 온도 구배제어에 있어 복사열 전달의 효과)

  • Park, Tae-Yong;Shin, Yun-Ji;Ha, Minh-Tan;Bae, Si-Young;Lim, Young-Soo;Jeong, Seong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.522-527
    • /
    • 2019
  • In order to fabricate high-quality SiC substrates for power electronic devices, various single crystal growing methods were prepared. These include the physical vapor transport (PVT) and top seeded solution growth (TSSG) methods. All the suggested SiC growth methods generally use induction-heating furnaces. The temperature distribution in this system can be easily adjusted by changing the hot-zone design. Moreover, precise temperature control in the induction-heating furnace is favorably required to grow a high-quality crystal. Therefore, in this study, we analyzed the heat transfer in these furnaces to grow SiC crystals. As the growth temperature of SiC crystals is very high, we evaluated the effect of radiation heat transfer on the temperature distribution in induction-heating furnaces. Based on our simulation results, a heat transfer strategy that controls the radiation heat transfer was suggested to obtain the optimal temperature distribution in the PVT and TSSG methods.

Simulator for Dynamic 2/3-Dimensional Switching of Computing Resources

  • Ki, Jang-Geun;Kwon, Kee-Young
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.9-17
    • /
    • 2020
  • In this paper, as part of the research for the infrastructure of very high flexible and reconfigurable data center using very high speed crossbar switches, we developed a simulator that can model two and three dimensional connection structure of switches with an efficient control algorithm using software defined network and verified the functions and analyzed the performance accordingly. The simulator consists of a control module and a switch module that was coded using Python language based on the Mininet and Ryu Openflow frameworks. The control module dynamically controls the operation of switching cells using a shortest multipath algorithm to calculate efficient paths adaptively between configurable computing resources. Performance analysis by using the simulator shows that the three-dimensional switch architecture can accommodate more hosts per port and has about 1.5 times more successful 1:n connections per port with the same number of switches than the two-dimensional architecture. Also simulation results show that connection length in a 3-dimensional way is shorter than that of 2-dimensional way and the unused switch ratio in a 3-dimensional case is lower than that of 2-dimensional cases.

A novel hybrid control of M-TMD energy configuration for composite buildings

  • ZY Chen;Yahui Meng;Ruei-Yuan Wang;T. Chen
    • Steel and Composite Structures
    • /
    • v.48 no.4
    • /
    • pp.475-483
    • /
    • 2023
  • In this paper, a new energy-efficient semi-active hybrid bulk damper is developed that is cost-effective for use in structural applications. In this work, the possibility of active and semi-active component configurations combined with suitable control algorithms, especially vibration control methods, is explored. The equations of motion for a container bridge equipped with an MDOF Mass Tuned Damper (M-TMD) system are established, and the combination of excitation, adhesion, and control effects are performed by a proprietary package and commercial custom submodel software. Systematic methods for the synthesis of structural components and active systems have been used in many applications because of the main interest in designing efficient devices and high-performance structural systems. A rational strategy can be established by properly controlling the master injection frequency parameter. Simulation results show that the multiscale model approach is achieved and meets accuracy with high computational efficiency. The M-TMD system can significantly improve the overall response of constrained structures by modestly reducing the critical stress amplitude of the frame. This design can be believed to build affordable, safe, environmentally friendly, resilient, sustainable infrastructure and transportation.

An Efficient Topology/Parameter Control in Evolutionary Design for Multi-domain Engineering Systems

  • Seo, Ki-Sung
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.2
    • /
    • pp.108-113
    • /
    • 2005
  • This paper suggests a control method for an efficient topology/parameter evolution in a bond graph-based GP design framework that automatically synthesizes designs for multi-domain, lumped parameter dynamic systems. We adopt a hierarchical breeding control mechanism with fitness-level-dependent differences to obtain better balancing of topology/parameter search - biased toward topological changes at low fitness levels, and toward parameter changes at high fitness levels. As a testbed for this approach in bond graph synthesis, an eigenvalue assignment problem, which is to find bond graph models exhibiting minimal distance errors from target sets of eigenvalues, was tested and showed improved performance for various sets of eigenvalues.

Lateral Drift Control Technique of High-Rise Shear Wall Core Structural System (고층 전단벽 코어구조시스템의 횡변위 제어방안)

  • Han, Seong-Baek;Kang, Myoung-Hee;Nam, Kyung-Yun;Lee, Seong-Su;Lee, Han-Joo;Kim, Ho-Soo
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.151-154
    • /
    • 2008
  • This study presents the efficient lateral drift control optimal technique that can control quantitatively lateral drift of high-rise structures. To this end, optimal design algorithm is formulated and then lateral drift control optimal program is developed. The 130 story shear wall core model is considered to illustrate the features of lateral drift control technique proposed in this study

  • PDF

The Proposition of Efficient Nonlinear Solution Technique for Space Truss (공간 트러스에 대한 효율적인 비선형 해석 기법 제안)

  • 석창목;권영환
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.481-490
    • /
    • 2002
  • The purpose of this paper is to evaluate the efficiency of various solution techniques and propose new efficient solution techniques for space trusses. Solution techniques used in this study are three load control methods (Newton-Raphson Method, modified Newton-Raphson Method, Secant-Newton Method), two load-displacement control methods(Arc-length Method, Work Increment Control Method) and three combined load-displacement control methods(Combined Arc-length Method I , Combined Arc-length MethodⅡ, Combined Work Increment Control Method). To evaluate the efficiency of these solution techniques, we must examine accuracy of their solutions, convergences and computing times of numerical examples. The combined load-displacement control methods are the most efficient in the geometric nonlinear solution techniques and in tracing post-buckling behavior of space truss. The combined work increment control method is the most efficient in tracing the buckling load of spate trusses with high degrees of freedom.

An Economic Design of the EWMA Control Charts with Variable Sampling Interval (VSI EWIMA 관리도의 경제적 설계)

  • 송서일;정혜진
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.4
    • /
    • pp.1-14
    • /
    • 2002
  • Traditional SPC techniques are looking out variation of process by fixed sampling interval and fixed sample size about every hour, the process of in-control or out-of-control couldn't be detected actually when the sample points are plotted near control limits, and it takes no notice of expense concerned with such sample points. In this paper, to overcome that, consider VSI(variable sampling interval) EWMA control charts which VSI method is applied. The VSI control charts use a short sampling internal if previous sample points are plotted near control limits, then the process has high probability of out-of-control. But it uses a long sampling interval if they are plotted near centerline of the control chart, since process has high possibility of in-control. And then a comparison and analysis between FSI(fixed sampling interval) and VSI EWMA in the statistical aspect and economic aspect is studied. Finally, we show that VSI EWMA control chart is more efficient than FSI EWMA control chart in the both aspects.

On the Voltage-Based Control of Robot Manipulators

  • Fateh, Mohammad Mehdi
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.702-712
    • /
    • 2008
  • This paper presents a novel approach for controlling electrically driven robot manipulators based on voltage control. The voltage-based control is preferred comparing to torque-based control. This approach is robust in the presence of manipulator uncertainties since it is free of the manipulator model. The control law is very simple, fast response, efficient, robust, and can be used for high-speed tracking purposes. The feedback linearization is applied on the electrical equations of the dc motors to cancel the current terms which transfer all manipulator dynamics to the electrical circuit of motor. The control system is simulated for position control of the PUMA 560 robot driven by permanent magnet dc motors.