• Title/Summary/Keyword: High Early Strength Cement

Search Result 303, Processing Time 0.027 seconds

An Experimental Study on the Physical Properties of Porous Cement Concrete Using Blast-furnace Slag as an Admixture (고로슬래그를 혼화재로 혼입한 투수콘크리트의 물리적 특성에 과한 실험적 연구)

  • 심종우;채창우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.144-149
    • /
    • 2000
  • Porous cement concrete was developed to prevent hydroplaning of airway pavement or to reduce noise emission in highway. In has been introduced in domestic since early 1980' and applied to a pedestrian road or bike way. The concrete, however, has problems such as lack of optimized mix design, low strength and deterioration, etc. The purpose of this study is to manufacture porous cement concrete using blast-furnace slag to enhance mechanical properties. The results of this study are as follows; the compressive strength range is 102∼247kgf/㎠, the tensile strength range is 16∼70kgf/㎠, the bending strength range is 43∼70kgf/㎠, and the coefficient permeability range is 6.79 ×10-2∼1.17∼10-1cm/sec. To develope high-performance porous concrete, further studies are needed on optimum mixture of fineness modulus and admixture.

  • PDF

Compressive Strength Properties of Concrete According to Binder Types and Cement Fineness (결합재 종류 및 시멘트 분말도 변화에 따른 콘크리트의 강도 특성)

  • Park, Do-Young;Park, Nam-Yong;Kim, Dong-Woo;Shin, Hyun-Sup;Yang, Hyun-Soo;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.5-6
    • /
    • 2017
  • This study is to analyze the properties of concrete according to the types of binders and cement powder and to utilize them as fundamental data for the development of early strength concrete. In the case of fluidity, all of the formulations satisfied the 180±25mm, and the flowability of HSF was decreased by high fineness cement. For the air content, 4.5±1.5% of the total content was satisfied. Compressive strength of HSF was found to satisfy the 5MPa in 2days of aging. In case of 28 days of aging, the strength of HSF was more than 24MPa.

  • PDF

Hydration Characteristics and Synthesis of Hauyne-Belite Cement as Low Temperature Sintering Cementitious Materials

  • Park, Sang-Jin;Jeon, Se-Hoon;Kim, Kyung-Nam;Song, Myong-Shin
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.3
    • /
    • pp.224-229
    • /
    • 2018
  • OPC production requires high calorific value and emits a large amount of $CO_2$ through decarbonation of limestone, accounting for about 7% of $CO_2$ emissions. To reduce $CO_2$ emissions during the Ordinary Portland Cement (OPC) production process, there is a method of reducing the consumption of cement or lower temperature calcination for OPC product. In this study, for energy consumption reduction, we prepared Hauyne-belite cement by calcination at a low temperature compared to that used for OPC and studied the early hydration properties of the synthesized Hauyne-belite cement. We set the ratios of Hauyne and belite to 8 : 2, 5 : 5 and 3 : 7. For the hydration properties of the synthesized Hauyne-belite cement, we tested heat of hydration of paste and the compressive strength of mortar, using XRD and SEM for analysis of hydrates. As for our results, the temperature for optimum synthesis of Hauyne-belite is $1,250^{\circ}C$. Compressive strength of synthesized Hauyne-belite cement is lower than that of OPC, but it is confirmed that compressive strength of synthesized Hauyne-belite cement with mixing in of some other materials can be similar to that of OPC.

Spalling Properties of High Performance Concrete Designed with the Various Blaine of Cement, Mineral Admixture Types and Fiber Contents (시멘트 입도, 혼화재 종류 및 PP섬유 혼입률 변화에 따른 고성능 콘크리트의 폭렬특성)

  • Song, Yong-Won;Shin, Jae-Kyung;Lee, Jae-Sam;Hann, Chang-Pyung;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.103-106
    • /
    • 2006
  • This study investigates spalling properties of 60MPa class, high performance concrete, made with the various influential parameters, such as, blaine of cement, mineral admixture and polypropylene(PP) fiber contents. Totally 21 parameters of ${\phi}100{\times}200mm$ in size was fabricated; three specimens for variance in blaine of cement, 4 specimens for combination of mineral admixture type, along with 0.05, 0.1, 0.15% of fiber adding ratio. After that, one hour unloading fire test was conducted, and then spalling appearance and spalling degree of specimens was examined. Test showed that a specimen made with high blaine of cement(H) improved early strength but exhibited similar value to a specimen made with low blaine(L) at the age of 28 days, thus indicating comparable spalling appearance. In conclusion, spalling easily occur in higher strength and smaller particle shape of cement and mineral admixture.

  • PDF

Evaluation of Air Void System and Permeability of Latex-Modified Concrete by Image Analysis Method

  • Jeong, Won-Kyong;Yun, Kyong-Ku;Hong, Seung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.41-48
    • /
    • 2007
  • Addition of latex to concrete is known to increase its durability and permeability. The purpose of this study is to analyze air void systems in latex-modified concretes using a reasonable and objective method of image analysis with such experimental variables as water-cement (w/c) ratios, latex contents (0%, 15%) and cement types (ordinary portland cement (OPC), high-early strength (HES) cement and very-early strength (VES) cement). The results are analyzed by spacing factor, air volume (content) after hardening, air void distribution and structure. Additionally, air void systems and permeability of latex-modified concrete (LMC) are compared by a correlation analysis. The results are as follows. The LMC of the same w/c ratio showed better air entraining (AE) effect than OPC with AE water reducer. The VES-LMC showed that the quantity of entrained air below $100{\mu}m$ increased more than four times. For the case of HES-LMC, microscopic entrained air between the range of 50 to $500{\mu}m$ increased greater than 7 times even in the absence of anti-foamer. Although spacing factor was measured rather low, the permeability of latex-modified concrete was good. It is construed that air void system does not have a considerable effect on the property of latex-modified concrete, but latex film (membrane) has a definite influence on the durability of LMC.

A Study on the Manufacture and Application of Ultra-high Strength Concrete (초고강도 콘크리트의 제조 및 현장적용성에 관한 연구)

  • Choi, Il-Ho;Jung, Yang-Hee;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.1-4
    • /
    • 2007
  • Because reinforced concrete structures were being high more and more in recent year, concrete was being demanded high performance of high strength and high fluidity. But various characteristics must be confirmed besides guarantee of demand strength in ultra-high strength concrete. In ultra-high strength concrete, autogenous shrinkage and drying shrinkage grow big because of a low water cement ratio and much quantity of binder. So dangerousness of crack generation grow big in early ages. And ultra-high strength concrete is influenced by use materials more than ordinary strength concrete. In this study we were examined mix design, atuogenous shrinkage and pumpability of ultra-high strength concrete to apply on the ground.

  • PDF

Compressive Strength Properties of Steam-cured High Volume GGBFS Cement Concrete (증기양생한 고로슬래그 다량치환 시멘트 콘크리트의 압축강도 특성)

  • Hong, Seong-Hyun;Kim, Hyung-Suk;Choi, Seul-Woo;Lee, Kwang-Myong;Choi, Se-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Recently, lots of researches on concrete with high volume mineral admixture such as ground granulated blast furnace slag (GGBFS) have been carried out to reduce $CO_2$. It is known that the precast concrete has an advantage of high strength at early age due to steam curing, even if concrete has high replacement level of mineral admixture. However it demands the investigation of compressive strength properties according to steam curing regimens. In this study, concretes with water-binder ratio of 32, 35% and water content of 135, 150, $165kg/m^3$ were produced to investigate compressive strength properties of high volume (60% by mass) GGBFS cement concrete according to steam curing regimens. Then steam curing was implemented with the maximum temperature of 50, $60^{\circ}C$ and steaming time of 5, 6, 7 hours. From the test results, it was found that steam curing was effective to raise early strength of high volume GGBFS cement concrete, but 28 day compressive strengths of steam cured specimens were lower than those of water cured specimens. Thus, a further study would be needed for the optimum steam curing regimens to satisfy target demolded strength and specified strength for the application of high volume GGBFS cement concrete to precast concrete members.

Characteristics of concrete intensity using high early strength AE water reducing agent (조강형 AE감수제를 사용한 콘크리트의 강도발현 특성)

  • Kim, Jung-Tai;Kim, Seung-Han;Jang, Seck-Soo;Jung, Yong-Wook;Yeo, In-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.793-796
    • /
    • 2008
  • Recently early strength concrete has been required for economical assurance and the prevention of frost damage in winter through air reduction in construction of concrete structures. This study presented the optimum condition revealing compressive strength 5MPa which has the possibility of removal of form in 24 hours, and researched the changes of unit weight of cement types of high early strength AE water reducing agents, characteristic of compressive strength expression as cure temperature conditions and slump or airspace. Test results showed at $15^{\circ}C$ with compressive strength of 5MPa that premature removal of form was possible in case of using highly early strength PC water reducing agent with unit weight of cement 360 ; 22hours faster than 10, unit weight 360 ; 20hours faster than 7, unit weight 390 ; 18 hours faster than 4 comparing with OP water reducing agent. And at $5^{\circ}C$ in case of using highly early strength PC water reducing agent with unit weight of cement 330 ; 32hours faster than 10, unit weight 360 ; 30hours faster than 7, unit weight390 ; 27hours faster than 4 comparing with OP water reducing agent. Therefore as the temperature rises $10^{\circ}C$, compressive strength of 5MPa reaching hour shortens 10 hours.

  • PDF

An Experimental Study on the Properties of UHPC with Different Types of Cements (시멘트 종류에 따른 초고성능 콘크리트의 특성에 관한 실험적 연구)

  • Park, Jung-Jun;Kang, Su-Tae;Ryu, Gum-Sung;Koh, Gyung-Taek;Kim, Sung-Wook;Lee, Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.345-348
    • /
    • 2008
  • A Cement account for the most amount than other materials in the material composition of ultra-high-performance concrete. If we especially consider the effect of high temperature curing on the cement hydration and the problems of autogenous shrinkage, heat of hydration we need selection of proper cement type by grasping influence of cement in the properties of UHPC. Therefore, in this paper we examined properties of fluidity, compressive strength and elastic modulus of UHPC due to domestic portland cement types. In results, we could get a result that the low heat cement increase fluidity, compressive strength in UHPC compare with high early strength cement and ordinary portland cement. we are systematically going to examination on the influence of UHPC by domestic portland cement types.

  • PDF

Compressive and Adhesive Strengths of Mortars using Re-emulsification Type Polymer and Ultra-Rapid-Hardening Cement (재유화형 분말수지와 초속경 시멘트를 혼입한 모르타르의 압축강도 및 접착강도 특성)

  • Lee, Kwang-Il;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.329-335
    • /
    • 2018
  • The objective of this study is to develop a mortar mixture with high workability and adhesive strength for section jacketing in seismic strengthening technology of existing concrete structures. To achieve targeted requirements of the mortars (initial flow exceeding 200 mm, compressive strength of 30MPa, and adhesive strength exceeding 1MPa), step-by-step tests were conducted under the variation of the following mixture parameters: water-to-binder ratio, sand-to-binder ratio, polymer-to-binder ratio, dosage of viscosity agent, and content of ultra-rapid-hardening cement. The adhesive strength of the mortars was also estimated with respect to the various surface treatment states of existing concrete. Based on the test results, the mortar mixture with the polymer-to-binder ratio of 10% and the content of ultra-rapid-hardening cement of 5% can be recommended for the section jacketing materials. The recommended mortar mixture satisfied the targeted requirements as follows: initial flow of 220 mm, high-early strength gain, 28-day compressive strength of 35MPa, and adhesive strength exceeding 1.2MPa.