• 제목/요약/키워드: HfN

검색결과 487건 처리시간 0.027초

Conformational Study of Pseudo-Proline Dipeptide in the Gas Phase and Solutions

  • Park, Hae-Sook;Kang, Young-Kee
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.158.1-158.1
    • /
    • 2003
  • We report here the results on N-acetyl-N"-methylamide of oxazolidine (Ac-Oxa-NHMe) calculated using the ab initio molecular orbital method with the self-consistent reaction field (SCRF) theory at the HF level of theory with the 6-31 +G(d) basis set. The displacement of the $\gamma$-$CH_2$ group in proline ring by oxygen atom has affected the structure of proline, cis-trans equilibrium, and rotational barrier. The up-puckered structure is found to be prevalent for the trans conformers of the Oxa amide. (omitted)

  • PDF

심부전 환자의 신체활동과 규칙적 운동에 대한 측정의 일관성 및 운동역량과 삶의 질과의 관련성 (Consistency in Measuring Physical Activities and Regular Exercises and Their Relationship with Exercise Capacity and Quality of Life in Patients with Heart Failure)

  • 이해정;진혜경;박지나;전국진;김종현
    • Journal of Korean Biological Nursing Science
    • /
    • 제16권4호
    • /
    • pp.284-291
    • /
    • 2014
  • Purpose: In order to examine whether daily physical activity (DPA) can be considered the same as a regular exercise (RE) in patients with Heart Failure (HF), we examined the relationship between RE and DPA, and we explored the relationship of RE and DPA with exercise capacity and quality of life (QOL) in patients with HF. Methods: This cross-sectional, correlational study utilized pretest data (N=136) of a long-term intervention study. Data of the parent study were collected from May 1st to September 26th, 2013. Measures included questions about regular exercise, International Physical Activity Questionnaire, a 6-Minute Walk Test (6MWT), and the Kansas City Cardiomyopathy Questionnaire (KCCQ). The data were analyzed using descriptive analysis, Chi-square test, and ANOVA using the SPSS 21.0 program. Results: There were inconsistencies in measures between RE and DPA. About 42.0% of the participants engaging in health enhancing physical activity did not consider themselves to be regular exercisers. Depending on the levels of RE and DPA, significant differences in 6MWT and QOL were observed. Conclusion: RE is more likely to be related to the health status of patients with HF. Deliberate assessment and cautious interpretation of DPA in patients with HF is needed.

Canonical Correlation of 3D Visual Fatigue between Subjective and Physiological Measures

  • Won, Myeung Ju;Park, Sang In;Whang, Mincheol
    • 대한인간공학회지
    • /
    • 제31권6호
    • /
    • pp.785-791
    • /
    • 2012
  • Objective: The aim of this study was to investigate the correlation between 3D visual fatigue and physiological measures by canonical correlation analysis enabling to categorical correlation. Background: Few studies have been conducted to investigate the physiological mechanism underlying the visual fatigue caused by processing 3D information which may make the cognitive mechanism overloaded. However, even the previous studies lack validation in terms of the correlation between physiological variables and the visual fatigue. Method: 9 Female and 6 male subjects with a mean age of $22.53{\pm}2.55$ voluntarily participated in this experiment. All participants were asked to report how they felt about their health sate at after viewing 3D. In addition, Low & Hybrid measurement test(Event Related Potential, Steady-state Visual Evoked Potential) and for evaluating cognitive fatigue before and after viewing 3D were performed. The physiological signal were measured with subjective fatigue evaluation before and after in watching the 3D content. For this study suggesting categorical correlation, all measures were categorized into three sets such as included Visual Fatigue set(response time, subjective evaluation), Autonomic Nervous System set(PPG frequency, PPG amplitude, HF/LF ratio), Central Nervous System set(ERP amplitude P4, O1, O2, ERP latency P4, O1, O2, SSVEP S/N ratio P4, O1, O2). Then the correlation of three variables sets, canonical correlation analysis was conducted. Results: The results showed a significant correlation between visual fatigue and physiological measures. However, different variables of visual fatigue were highly correlated to respective HF/LF ratio and to ERP latency(O2). Conclusion: Response time was highly correlated to ERP latency(O2) while the subjective evaluation was to HF/LF ratio. Application: This study may provide the most significant variables for the quantitative evaluation of visual fatigue using HF/LF ratio and ERP latency based human performance and subjective fatigue.

Dielectric and Optical Properties of Amorphous Hafnium Indium Zinc Oxide Thin Films on Glass Substrates

  • Shin, Hye-Chung;Seo, Soon-Joo;Denny, Yus Rama;Lee, Kang-Il;Lee, Sun-Young;Oh, Suhk-Kun;Kang, Hee-Jae;Heo, Sung;Chung, Jae-Gwan;Lee, Jae-Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.225-225
    • /
    • 2011
  • The dielectric and optical properties of GaInZnO (GIZO), HfInZnO (HIZO) and InZnO (IZO) thin films on glass by RF magnetron sputtering method were investiged using reflection electron energy loss spectroscopy (REELS). The band gap was estimated from the onset values of REELS spectra. The band gaps of GIZO, HIZO and IZO thin films are 3.1 eV, 3.5 eV and 3.0 eV, respectively, Hf and Ga incorporated into IZO results in an increase in the energy band gap of IZO by 0.5 eV and 0.1 eV. The dielectric functions were determined by comparing the effective cross section determined from experimental REELS with a rigorous model calculation based on the dielectric response theory, using available software package, good agreement between the experimental and fitting results gives confidence in the accuracy of the determined dielectric function. The main peak of Energy Loss Function (ELF) obtained from IZO shows at 18.42 eV, which shifted to 19.43 eV and 18.15 eV for GIZO and HIZO respectively, because indicates the corporation of cation Ga and Hf in the composition. The optical properties represented by the dielectric function e, the refractive index n, the extinction coefficient k, and the transmission coefficient, T of HIZO and IZO thin films were determined from a quantitative analysis of REELS. The transmission coefficient was increased to 93% and decreased to 87% in the visible region with the incorporation of Hf and Ga in the IZO compound.

  • PDF

ZnS:Cu,Cl 형광체의 특성에 미치는 원자층 증착 초박막 HfO2의 영향 (Effect of Ultrathin Film HfO2 by Atomic Layer Deposition on the Propreties of ZnS:Cu,Cl Phosphors)

  • 김민완;한상도;김형수;김혁종;김휴석;김석환;이상우;최병호
    • 한국재료학회지
    • /
    • 제16권4호
    • /
    • pp.248-252
    • /
    • 2006
  • An investigation is reported on the coating of ZnS:Cu,Cl phosphors by $HfO_2$ using atomic layer deposition method. Hafnium oxide films were prepared at the chamber temperature of $280^{\circ}C$ using $Hf[N(CH_3)_2]_4\;and\;O_2$ as precursors and reactant gas, respectively. XPS and ICP-MS analysis showed the surface composition of coated phosphor powder was hafnium oxide. In FE-SEM analysis, the surface morphology of uncoated phosphors became smoother and clearer as the number of ALD cycle increased from 900 to 1800. The photoluminescence intensity for coated phosphors showed $7.3{\sim}13.4%$ higher than that of uncoated. The effect means that the reactive surface is uniformly coated with stable hafnium oxide to reduce the dead surface layer without change of bulk properties and also its absorptance is almost negligible due to ultrathin(nano-scaled) films. The growth rate is about $1.1{\AA}/cycle$.

Microtensile bond strength and micromorphologic analysis of surface-treated resin nanoceramics

  • Park, Joon-Ho;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.275-284
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the influence of different surface treatment methods on the microtensile bond strength of resin cement to resin nanoceramic (RNC). MATERIALS AND METHODS. RNC onlays (Lava Ultimate) (n=30) were treated using air abrasion with and without a universal adhesive, or HF etching followed by a universal adhesive with and without a silane coupling agent, or tribological silica coating with and without a universal adhesive, and divided into 6 groups. Onlays were luted with resin cement to dentin surfaces. A microtensile bond strength test was performed and evaluated by one-way ANOVA and Tukey HSD test (${\alpha}$=.05). A nanoscratch test, field emission scanning electron microscopy, and energy dispersive X-ray spectroscopy were used for micromorphologic analysis (${\alpha}$=.05). The roughness and elemental proportion were evaluated by Kruskal-Wallis test and Mann-Whitney U test. RESULTS. Tribological silica coating showed the highest roughness, followed by air abrasion and HF etching. After HF etching, the RNC surface presented a decrease in oxygen, silicon, and zirconium ratio with increasing carbon ratio. Air abrasion with universal adhesive showed the highest bond strength followed by tribological silica coating with universal adhesive. HF etching with universal adhesive showed the lowest bond strength. CONCLUSION. An improved understanding of the effect of surface treatment of RNC could enhance the durability of resin bonding when used for indirect restorations. When using RNC for restoration, effective and systemic surface roughening methods and an appropriate adhesive are required.

질화막 성장의 하지의존성에 따른 적층캐패시터의 이상산화에 관한 연구 (A Study on the Abnormal Oxidation of Stacked Capacitor due to Underlayer Dependent Nitride Deposition)

  • 정양희
    • 한국전기전자재료학회논문지
    • /
    • 제11권1호
    • /
    • pp.33-40
    • /
    • 1998
  • The composite SiO$_2$/Si$_3$N$_4$/SiO$_2$(ONO) film formed by oxidation on nitride film has been widely studied as DRAM stacked capacitor multi-dielectric films. Load lock(L/L) LPCVD system by HF cleaning is used to improve electrical capacitance and to scale down of effective thickness for memory device, but is brings a new problem. Nitride film deposited using HF cleaning shows selective deposition on poly silicon and oxide regions of capacitor. This problem is avoidable by carpeting chemical oxide using $H_2O$$_2$cleaning before nitride deposition. In this paper, we study the limit of nitride thickness for abnormal oxidation and the initial deposition time for nitride deposition dependent on underlayer materials. We proposed an advanced fabrication process for stacked capacitor in order to avoid selective deposition problem and show the usefulness of nitride deposition using L/L LPCVD system by $H_2O$$_2$cleaning. The natural oxide thickness on polysilicon monitor after HF and $H_2O$$_2$cleaning are measured 3~4$\AA$, respectively. Two substrate materials have the different initial nitride deposition times. The initial deposition time for polysilicon is nearly zero, but initial deposition time for oxide is about 60seconds. However the deposition rate is constant after initial deposition time. The limit of nitride thickness for abnormal oxidation under the HF and $H_2O$$_2$cleaning method are 60$\AA$, 48$\AA$, respectively. The results obtained in this study are useful for developing ultra thin nitride fabrication of ONO scaling and for avoiding abnormal oxidation in stacked capacitor application.

  • PDF

Effects of Three Recumbent Postures on Autonomic Nervous System in Patients with Coronary Artery Disease

  • Kim, Wuon-Shik;Hwang, In-Kyoung;Choi, Hyoung-Min
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제3권2호
    • /
    • pp.10-16
    • /
    • 2005
  • Because patients with coronary artery disease (CAD) have depressed vagal modulation and the mortality risk from acute myocardial infarction is lower in patients with higher vagal modulation, methods that can increase vagal modulation are desirable in patients with CAD. We intended to inspect the effect of recumbent posture on vagal modulation. By using angiography, 33 patients with abnormal (CAD group) and 33 patients with normal coronary arteries (control group) were studied. The nonlinear as well as the linear characteristics of heart rate variability (HRV) were analyzed on these patients in three recumbent postures: namely, the supine, right lateral decubitus, and left lateral decubitus postures. The lower the normalized high-frequency power (nHF) in the supine or left lateral decubitus posture, the higher the increase in the nHF when the posture was changed from supine or left lateral decubitus to right lateral decubitus in both groups of patients. Right lateral decubitus posture can lead to the highest vagal modulation and the lowest sympathetic modulation among the three recumbent postures in both normal and patients with CAD. Therefore, the right lateral decubitus posture can be used as an effective physiologic vagal enhancer in patients with CAD.

  • PDF

임상실습이 간호학생의 스트레스, 불안 및 자율신경계 변화에 미치는 영향 (Effects of Clinical Training on Stress, Anxiety and Changes in Autonomic Nervous System in Nursing Students)

  • 김진일;이정순
    • Journal of Korean Biological Nursing Science
    • /
    • 제13권2호
    • /
    • pp.102-108
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of first clinical training on stress, anxiety and changes in autonomic nervous system in nursing students. Methods: Seventy-four nursing students were assigned to the experimental group (n=36) that had two weeks of clinical training, and the control group (n=38) that had only two weeks of regular classes. Perceived stress, state anxiety and heart rate variability (HRV) were measured at the beginning and end of the experiment. Results: Perceived stress in the experimental group was significantly higher than in the control group. However, State anxiety was not significantly different between the two groups. All indices of HRV except LF/HF ratio were significantly different between the two groups. LF norm in the experimental group was significantly higher than in the control group, and HF norm in the experimental group was significantly lower than in the control group. Conclusion: Based on these results, it can be suggested that clinical training increases the perceived stress and affects the changes in autonomic nervous system in nursing students.

피톤치드 아로마테라피가 간호대학생의 스트레스, 스트레스 증상 및 심박변이도에 미치는 영향 (Effects of Phytoncide Aromatherapy on Stress, Symptoms of Stress and Heart Rate Variability among Nursing Students)

  • 김철규;조미경;김진일
    • Journal of Korean Biological Nursing Science
    • /
    • 제14권4호
    • /
    • pp.249-257
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of phytoncide aromatherapy on stress, symptoms of stress and heart rate variability among nursing students. Methods: This study is a randomized control-group non-synchronized design. The experimental group (n=31) underwent phytoncide aromatherapy for 2 weeks, while the control group (n=31) received placebo therapy. The data were collected using self-administration questionnaires and measurement of heart rate variability (HRV) and analyzed using SPSS WIN 18.0 program. A p value <.05 was considered statistically significant. Results: Total score of stress, individual score of intrapersonal stress, and score of peripheral manifestations in symptoms of stress in the experimental group were significantly lower than those of the control group. All indices of HRV were significantly different between the two groups. LF norm and LF/HF ratio in the experimental group were significantly lower than those of the control group, and HF norm in the experimental group was significantly higher than that of in the control group. Conclusion: Based on these results, it can be suggested that phytoncide aromatherapy was effective in decreasing stress and peripheral manifestations of stress and changing in HRV among nursing students.