• Title/Summary/Keyword: Heavy Plate

Search Result 315, Processing Time 0.031 seconds

Corrosion Behavior of Pyro-Carbon in Hot Lithium Molten Salt Under an Oxidation Atmosphere (산화성 고온 리튬용융염계 분위기에서 Pyro-Carbon의 부식거동)

  • Lim, Jong-Ho;Choi, Jeong-Mook
    • Korean Journal of Materials Research
    • /
    • v.23 no.2
    • /
    • pp.123-127
    • /
    • 2013
  • The electrolytic reduction of a spent oxide fuel involves liberation of the oxygen in a molten LiCl electrolyte, which is a chemically aggressive environment that is too crosive for typical structural materials. Therefore, it is essential to choose the optimum material for the process equipment for handling a molten salt. In this study, the corrosion behavior of pyro-carbon made by CVD was investigated in a molten LiCl-$Li_2O$ salt under an oxidation atmosphere at $650^{\circ}C$ and $750^{\circ}C$ for 72 hours. Pyro-carbon showed no chemical reactions with the molten salt because of its low wettability between pyro-carbon and the molten salt. As a result of XRD analysis, pyro-carbon exposed to the molten salt showed pure graphite after corrosion tests. As a result of TGA, whereas the coated layer by CVD showed high anti-oxidation, the non-coated layer showed relatively low anti-oxidation. The stable phases in the reactions were $C_{(S)}$, $Li_2CO_{3(S)}$, $LiCl_{(l)}$, $Li_2O$ at $650^{\circ}C$ and $C_{(S)}$, $LiCl_{(l)}$, $Li_2O_{(S)}$ at $750^{\circ}C$. $Li_2CO_{(S)}$ was decomposed at $750^{\circ}C$ into $Li_2O_{(S)}$ and $CO_{2(g)}$.

Hot Corrosion Behavior of Inconel Alloys and Incoloy 800H in Molten LiCl-Li2O Salt (LiCl-Li2O 용융염에서 Inconel 합금 및 Incoloy 800H의 고온 부식거동)

  • Lim, Jong-Ho;Choi, Jeong-Mook
    • Korean Journal of Materials Research
    • /
    • v.23 no.2
    • /
    • pp.128-134
    • /
    • 2013
  • A study on the corrosion behavior of Inconel alloys and Incoloy 800H in molten salt of LiCl-$Li_2O$ was investigated at $650^{\circ}C$ for 24-312 hours in an oxidation atmosphere. The order of the corrosion rate was Inconel 600 < Inconel 601 < Incoloy 800H < Inconel 690. Inconel 600 showed the best performance suggesting that the content of Fe, Cr and Ni are the important factor for corrosion resistance in hot molten salt oxidation conditions. The corrosion products of Inconel 600 and Inconel 601 were $Cr_2O_3$ and $NiFe_2O_4$, In case of Inconel 690, a single layer of $Cr_2O_3$ was formed in the early stage of corrosion and an outer layer of $NiFe_2O_4$ and inner layer of $Cr_2O_3$ were formed with an increase of corrosion time. In the case of Incoloy 800H, $Cr_2O_3$ and $FeCr_2O_4$ were observed. Most of the outer scale of the alloys was observed to be spalled from the results of the SEM analysis and the unspalled scale which adhered to the substrate was composed of three layers. The outer layer, the middle one, and the inner one were Fe, Cr, and Ni-rich, respectively. Inconel 600 showed localized corrosion behavior and Inconel 601, 690 and Incoloy 800H showed uniform corrosion behavior. Ni improves the corrosion resistance and too much Cr and/or Fe content deteriorates the corrosion resistance.

Alteration of the Static Posture of Spine under Different Types and Amounts of Loading (가방 하중의 크기와 방식에 따른 척추 정적 자세의 변화)

  • Park, Yong-Hyun;Kim, Young-Kwan;Kim, Yoon-Hyuk
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.230-236
    • /
    • 2011
  • The aim of this study was to investigate the alteration of lumbar spine and trunk postures on different load-carrying types and amounts under static loading. Two load-carrying types(unilateral carrying: UC vs. bilateral carrying: BC) and four different loads(0, 5, 10, and 15 kg) were randomly tested in this study. Carrying a heavy bag would affect human body posture, specifically lumbar spine curvature, which is considered as one of sources of back problems. Previous studies have not paid attention to the approach of the multisegment model of the lumbar spine and trunk. This study separated two compartments of trunk segment(the lumbar and thorax) in the analysis. The multisegment model of the lumbar spine in addition to Helen-Hayes marker set was used. Eight motion analysis cameras and a force plate were utilized. Ten male subjects(mean mass, $70.6{\pm}3.97$ kg; mean height, $178{\pm}4.18$ m) having no musculoskeletal disease participated in this study. We analyzed trunk angles in three anatomical planes and the spinal curvature in sagittal and frontal planes. Increased loading in both UC and BC significantly resulted in increases in trunk forward lean but only UC induced increases in trunk lateral lean. In addition, increased loading in BC produced flatten lumbar curvature in sagittal plane. As far as coupling motion, subjects tended to use axial rotation of the lumbar spine in transverse plane in response to increased UC loading. Finally, it is concluded that the increased static loading in UC rather than in BC tends to causes combined alterations of the spinal postures(sagittal and transverse planes together), which would be vulnerable to improper mechanical stresses on the spine.

A Study on the Preparation of the Silver Selenide Electrode and Its Properties (Silver Selenide 전극의 제조 및 그 특성에 관한 연구)

  • Gwon-Shik Ihn;Tae-Won Min;Soo-Hyung Lee
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.4
    • /
    • pp.280-289
    • /
    • 1976
  • The silver selenide electrode has been prepared and its properties as an indicating electrode for silver ion have been investigated. Epoxy resin was used as a filler of silver selenide electrode. Silver metal plate was directly connected with the membrane of the electrode and the silver paste was used as its binder. The sintered electrode was more sensitive and stable than the pressed electrode, and the silver selenide electrode more sensitive than the silver sulfide electrode to silver ion. The linear relationship between the electrode potential and logarithmic concentration of silver ion has been observed down to 10-6 M for the electrode. Several heavy metal ions except mercuric ion did not interfere this linearity, but halide, cyanide, and thiocyanate ions did intensively interfere owing to the formation of silver compounds and complexes. This electrode has been applied to the potentiometric titration for determining halide ion. It is concluded that interferences from ,$CN^-, SCN^-, S^-, I^-, Br^-, Cl^- and Hg^{2+}$ ions are detrimental to the practical use of the electrodes for measuring pAg.

  • PDF

Zygoma-gear appliance for intraoral upper molar distalization (Zygoma-gear를 이용한 구치부 후방이동을 통한 비발치 치험례)

  • Nur, Metin;Bayram, Mehmet;Pampu, Alper
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.195-206
    • /
    • 2010
  • The aim of this report is to present an intraoral upper molar distalization system supported with zygomatic anchorage plates (Zygoma-gear Appliance, ZGA). This system was used for a 16-year-old female patient with a Class II molar relationship requiring molar distalization. The system consisted of bilateral zygomatic anchorage plates, an inner-bow and heavy intraoral elastics. Distalization of the upper molars was achieved in 3 months and the treatment results were evaluated from lateral cephalometric radiographs. According to the results of the cephalometric analysis, the maxillary first molars showed a distalization of 4 mm, associated with a distal axial inclination of $4.5^{\circ}$. The results of this study show that an effective upper molar distalization without anchorage loss can be achieved in a short time using the ZGA. We suggest that this new system may be used in cases requiring molar distalization in place of extraoral appliances.

Analysis of Dispersion Characteristics of Circumferential Guided Waves and Application to feeder Cracking in Pressurized Heavy Water Reactor (원주 유도초음파의 분산 특성 해석 및 가압중수로 피더관 균열 탐지에의 응용)

  • Cheong, Yong-Moo;Kim, Sang-Soo;Lee, Dong-Hoon;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.307-314
    • /
    • 2004
  • A circumferential guided wave method was developed to detect the axial crack on the bent feeder pipe. Dispersion curves of circumferential guided waves were calculated as a function of curvature of the pipe. In the case of thin plate, i.e. infinite curvature, as the frequency increases, the $S_0$ and $A_0$ mode coincide and eventually become Rayleigh wave mode. In the case of pipe, however, as the curvature increases, the lowest modes do not coincide even in the high frequencies. Based on the analysis, a rocking technique using angle beam transducer was applied to detect an axial defect in the bent region of PHWR feeder pipe. Based on the analysis of experimenal data for artificial notches, the vibration modes of each signal were identified. It was found that the notches with the depth of )0% of wall thickness can be detected with the method.

Numerical Analysis of Moving Type and Static Type Electrodynamic Suspension Simulator with Superconducting Levitation Magnet (초전도 부상자석을 이용한 동적 및 정지형 반발식 자기부상 시험기의 수치해석)

  • Lee, E.R.;Bae, D.K.;Chung, Y.D.;Yoon, Y.S.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • This paper presents the numerical simulation results on the moving type electrodynamic suspension (EDS) simulator and static type EDS simulator using high-Tc superconducting (HTS) levitation magnet. The levitation force of the EDS system is formed by the reaction between the moving magnet and the fixed ground conductor. The possible two ways to simulate the EDS system were simulated in this paper by using finite element method (FEM). The first way was the moving type simulator which consists of the fixed HTS magnet and the moving ground conductor. The second way was the static type simulator which consists of the fixed magnet, the fixed ground conductor and the ac current supply system. To verify the characteristics of high speed EDS system with the moving type simulator heavy, large and fast moving ground conductor is needed. The static type simulator can get the characteristics of the high speed EDS system by applying equivalent ac current to velocity, therefore it does not need large moving part. The static type EDS simulator, which can consist of an HTS magnet, the fixed ground conductor(s), an AC power supply and the measuring devices, also test the effect of the shape of the ground conductor easily. The plate type ground conductor made stronger levitation force than ring type ground conductor. Although the outer diameter 335 mm ring type ground conductor (Ring3) was larger than the outer diameter 235 mm ground conductor (Ring2), the levitation force by Ring2 was stronger than that by Ring3. From the calculation results on this paper, the consideration of the magnetic flux distribution according to the levitation height should be included in the process of the ground conductor design.

A Study on the Sanitation Condition for Products of Powdered Raw Grains and Vegetables (곡류 가공품 등의 위생실태에 관한 조사 연구)

  • Cho, Bae-Sick;Gang, Gyung-Lee;Lee, Hyang-Hee;Ha, Dong-Ryong;Kee, Hye-Young;Seo, Kye-Won;Kim, Eun-Sun;Park, Jong-Tae
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.273-278
    • /
    • 2007
  • Recently, the demand for the powdered products to process raw grains and vegetables has been expanded, and the growth possibility of their fields(markets) in the future will be highly valued with the westernization of living environment and the change of the dietary life. We have bought and analyzed the 111 products of raw grains and vegetables from the large-sized marts, markets and internet orders from March to October 2006. The rate of moisture content was $1.7{\sim}12.5%$. We also found out that the foods over 10% moisture content was 8 of those samples we bought or collected. Their ash rates were averagely $0.3{\sim}8.6%$. The number of those foods that the alien substances were detected was 2. The tar pigments, artificial sweeteners and sulfur dioxides of components that contained food additives were not detected. Each detection range of Cadmium, Lead and Arsenic of the injurious heavy metals was non-detectable $(nd){\sim}0.55,\;nd{\sim}4.52,\;nd{\sim}0.10mg/kg$, while the average detection content were 0.08, 0.48, 0.01 mg/kg. By investigating the contamination degree of the microflora, we discovered that the number of the aerobic plate count, B. cereus over 1,000 cfu/g and C. perfringens over 100 cfu/g was 36 (32.4%), 9 (8.1%) and zero, and that the whole sanitation condition of the products of powdered raw grains and vegetables circulated in the market was not so good.

Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON (한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션)

  • Bae, Jae-Beom;Cho, Byung-Cheol;Kwak, Jung-Won;Park, Woo-Yoon;Lim, Young-Kyung;Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The purpose of the Monte Carlo simulation study was to provide the optimized nozzle design to satisfy the beam conditions for biomedical researches in the Korean heavy-ion accelerator, RAON. The nozzle design was required to produce $C^{12}$ beam satisfying the three conditions; the maximum field size, the dose uniformity and the beam contamination. We employed the GEANT4 toolkit in Monte Carlo simulation to optimize the nozzle design. The beams for biomedical researches were required that the maximum field size should be more than $15{\times}15cm^2$, the dose uniformity was to be less than 3% and the level of beam contamination due to the scattered radiation from collimation systems was less than 5% of total dose. For the field size, we optimized the tilting angle of the circularly rotating beam controlled by a pair of dipole magnets at the most upstream of the user beam line unit and the thickness of the scatter plate located downstream of the dipole magnets. The values of beam scanning angle and the thickness of the scatter plate could be successfully optimized to be $0.5^{\circ}$ and 0.05 cm via this Monte Carlo simulation analysis. For the dose uniformity and the beam contamination, we introduced the new beam configuration technique by the combination of scanning and static beams. With the combination of a central static beam and a circularly rotating beam with the tilting angle of $0.5^{\circ}$ to beam axis, the dose uniformity could be established to be 1.1% in $15{\times}15cm^2$ sized maximum field. For the beam contamination, it was determined by the ratio of the absorbed doses delivered by $C^{12}$ ion and other particles. The level of the beam contamination could be achieved to be less than 2.5% of total dose in the region from 5 cm to 17 cm water equivalent depth in the combined beam configuration. Based on the results, we could establish the optimized nozzle design satisfying the beam conditions which were required for biomedical researches.

Risk Analysis for the Harvesting Stage of Tomato Farms to Establish the Good Agriculture Practices(GAP) (GAP 모델 확립을 위한 토마토 농장 수확단계의 위해요소 조사 및 분석)

  • Lee, Chae-Won;Lee, Chi-Yeop;Heo, Rok-Won;Kim, Kyeong-Yeol;Shim, Won-Bo;Shim, Sang-In;Chung, Duck-Hwa
    • Journal of agriculture & life science
    • /
    • v.46 no.4
    • /
    • pp.141-153
    • /
    • 2012
  • Samples collected from six tomato farms(A, B, C : soil culture, D, E, F : Nutriculture) located in Gyeongsangnam-do were tested for the analyses of biological(sanitary indications, major foodborne pathogens, fungi), chemical(heavy metals, pesticides) and physical hazards. The highest levels of total bacteria(7.5 log CFU/g) and coliforms(5.0 log CFU/g) in soil culture farms were higher than those of nutriculture farms(total bacteria: 2.5 log CFU/mL, coliforms: 0.6 log CFU/mL). In crops and personal hygiene soil culture farms showed a slightly higher contamination levels. From all farms, the levels of fungi in soil farms were higher than those of nutrient solution. In case of major pathogens, Bacillus cereus and Staphylococcus aureus were detected in all sample with the exception of nutrient solution. Meantime, Escherichia coli, Listeria monocytogenes, E.coli O157 and Salmonella spp. were not detected. For airborne bacteria, soilculture farms showed less contamination than nutriculture farms. A piece of glass and can was confirmed asphysical hazards. Heavy metal(Cd, Pb, Cu, Cr, Hg, Zn, Ni and As) and pesticide residues as chemical hazards were detected, but their levels were lower than the regulation limit. These results demonstrate that potential hazards on harvesting stage of tomato fam were exposed. Therefore, proper management is needed to prevent biological hazards due to cross-contamination, while physical and chemical hazards were in appropriate levels based on GAP criteria.