• Title/Summary/Keyword: Heat transfer of convection

Search Result 973, Processing Time 0.029 seconds

An Experimental Study on Natural Convection from a Conducting Tube with Two Axial Fins to a Surrounding Cylinder (두개의 축방향핀을 가진 전도관과 원통사이의 자연대류에 관한 실험적 연구)

  • Ahn, C.R.;Chung, T.H;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.26-33
    • /
    • 1991
  • An experimental study has been performed on the heat transfer by the natural convection from a conducting tube with two axial fins to a surrounding cylinder. In case of vertical fins, the maximum local Nusselt number of conducting tube appears at ${\theta}{\fallingdotseq}145^{\circ}$ and that of outer cylinder appears at ${\theta}=0^{\circ}$, for $l_F=0.3$. In case of horizontal fins, the maximum local Nusselt number of conducting tube appears at ${\theta}=180^{\circ}$ and that of outer cylinder appears at ${\theta}=0^{\circ}$. The local Nusselt number of the upper fin and the downward fin shows negative values for $l_F=1.0$. The local Nusselt number of the lower fin and the downward fin shows higher values than that of the upper fin and the upward fin. The mean Nusselt number of conducting tube in case of vertical fins are increased in order of $l_F=0.6$, 0.3, 1.0 and 0.0, but in case of horizontal fins, in order of $l_F=1.0$, 0.6, 0.3, and 0.0. The mean Nusselt number of outer cylinder in case of vertical fins are increased in order of $l_F=1.0$, 0.0, 0.3 and 0.6, but in case of horizontal fins, in order of $l_F=0.6$, 1.0, 0.3, and 0.0.

  • PDF

Numerical Analysis of Natural Convection from an Inclined Ice Flat Plate Immersed in cold Water Near Its Density Maximum (최대밀도점 부근의 물속에 잠겨있는 경사진 얼음평판에 의한 자연대류의 수치해석)

  • 유갑종;추홍록
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2136-2149
    • /
    • 1992
  • The natural convection from an inclined ice flat plate immersed in cold water near its density maximum is studied numerically. Finite difference analysis has been performed for the heat and momentum transfer with respect to various inclined angles and ambient water temperatures. The results of the analysis are presented for ambient water temperatures, 1.0deg. C. leq. T/sub .inf./.leq. 15.0deg. C and the inclined anales from 0deg to 60deg. They include velocity profiles, temperature profiles, melting velocities, and mean Nusselt numbers for entire flow fields, Generally, in the range of 0deg. C .leq.theta. .leq. 60.deg. C, the results show three distinct flow regimes, In the range of 1.0 deg. C .leq. T/sub .inf./ .leq. 4.6 .deg. C, the greatest mean Nuselt number exists about 3.0deg. C. In the range of 5.7deg. C .leq. T/sub .inf./ .leq. 15.0deg. C, mean Nuselt number increases as ambient water temperature increases. Also, the mean Nuselt number decreases as the inclined angle increases. This theoretical results are compared with previous experimental ones and multiple steady state ones.

A Numerical Study on the Natural Convection from Two Isothermal Square Beams Attached to an Vertical Adiabatic Plate (수직단열판에 부착된 2개의 등온 사각비임에서의 자연대류 열전달에 관한 수치 해석)

  • Park, Jae-Lim;Bae, Dae-Sok;Kwon, Sun-Sok
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.63-69
    • /
    • 1991
  • A Steady laminar natural convection heat transfer from two isothermal square beams attached to a vertical adiabatic plate has been studied numerically. The results have been obtained for dimensionless beam spacings, $0.5{\le}D/L{\le}3.0$, and for Gr=5000-10000 at ${\phi}_2/{\phi}_1=1.0$. 1. The local Nusselt number from the beam surface is increased with the dimension-less beam spacing D/L. but that of the downward surface of the lower beam is almost same as the D/L increases. And, the local Nusselt number from the upward surface of a lower beam is greatly increased with D/L. 2. The beam spacings of the maximum mean Nusselt number for the downward surface of an upper beam and the upward surface of a lower beam occur at. D/L =2.6 and 2.0 respectively. 3. The beam spacing for the maximum total mean Nusselt number occurs at D/L = 2.6.

  • PDF

A Study on the Natural Convection from the Isothermal Square Beam Attached to an Adiabatic Plate (단열판에 부착된 등온 사각비임에서의 자연대류 열전달에 관한 연구)

  • Park, Jae-Lim;Kwon, Sun-Sok
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.61-68
    • /
    • 1991
  • Steady laminar natural convection heat transfer from the isothermal square beam attached to an adiabatic plate has been studied for various inclination angles of the adiabatic plate and Rayleigh number by using Mach-Zehnder interferometer in air. As the inclination angles change, the different temperature and fluid flow field were obtained by the ascending heated fluid and the adiabatic plate. In this study, the inclination angles were $0^{\circ}$(positive & negative), $45^{\circ}$(positive & negative), and $90^{\circ}$. The maximum total mean Nusselt number value was found at a positive inclination angle ${\theta}=45^{\circ}$.

  • PDF

Heat Transfer Analysis around Transport Cask under Transport Hood (사용후핵연료 운반용기 덮개 내부 열전달 해석)

  • Lee, Dong-Gyu;Park, Jae-Ho;Jung, In-Su;Kim, Tae-Man;Yoon, Jeong-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.161-167
    • /
    • 2011
  • In case that the maximum temperature of any surface readily accessible during transport of a spent nuclear fuel (SNF) transport cask exceeds $85^{\circ}C$ in the absence of insolation under the ambient temperature of $38^{\circ}C$, personnel barriers or transport hood shall be used to prevent people from casual contact with the transport cask surface. Usually the air temperature within the hood and the hood surface temperature are calculated and further utilized as boundary conditions(free stream temperature and external radiation temperature) for thermal evaluation under normal conditions of transport. In this study, these temperatures are derived using the analytical method based on the heat transfer mechanism around the transport cask under transport hood assuming the thermal equilibrium. By comparing the analytical solutions with the results from the detailed calculations with CFD-computer-code FLUENT 12.1 it is verified that the analytical method is still efficient tool to estimate the temperatures and these temperatures can be further used as boundary conditions for thermal evaluation under normal conditions of transport.

A Study on the Thermoacoustic Oscillation of an Air Column (기주의 열음향진동에 관한 연구)

  • 권영필;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.253-261
    • /
    • 1987
  • Thermoacoustic oscillation of an air column induced by heated wires is investigated analytically and experimentally. Acoustic power generation from a single heater wire is estimated based on the result of heat transfer analysis and expressed in terms of the efficiency factor indicating the conversion efficiency from heat to acoustic energy. It is shown that the efficiency factor becomes maximum when the wire radius is the order of the coustic boundary layer thickness and the flow velocity is close to the thermal diffusion velocity. Onset condition of the column oscillation is obtained by equating the acoustic power generation at the heater to the power loss due to thermoviscous dissipation at the tube wall and the convection and radiationloss at the open ends of the tube. In estimating the acoustic power generation, the heater is treated as a stretched single wire by correcting the flow velocity to take into account the interactions between adjacent heater wires. Experiment is performed by using a spiral heater of 1mm diameter in an air column of 37mm diameter. The heat input to drive the oscillation is measured and compared with the theoretical prediction. A good agreement is found between the theory and experiment, which is regarded as a substantial verification of the present analysis.

Numerical Simulation of Standing Column Well Ground Heat Pump System Part 1: Validation of the Numerical Model (단일심정 지열히트펌프의 수치적 모델링 Part I: 수치해석 모델 검증)

  • Park, Du-Hee;Kim, Kwang-Kyun;Kwak, Dong-Yeop;Chang, Jae-Hoon;Park, Si-Sam
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.33-43
    • /
    • 2010
  • Geothermal energy is gaining wide attention as a highly efficient renewable energy and being increasingly used for heating/cooling systems of buildings. The standing column well (SCW) is especially efficient, cost-effective, and suitable for Korean geological and hydrological conditions. However, a numerical model that simulates the SCW has not yet been developed and applied in Korea. This paper describes the development of the SCW numerical model using a finite-volume analysis program. The model, through hydro-thermal coupled analyses, simulates heat transfer through advection, convection, and conduction. The accuracy of the model was verified through comparisons with field data measured at SCWs in the U.S. and Korea. Comparisons indicated that the SCW numerical model can closely predict the performance of a SCW. The numerical model was used to perform a comprehensive parametric study in the companion paper.

Studies on the Focusing Solar Agricultural Crop Dryer - Part1. Heat Efficiency of Aluminum-laminated Aeryl Film Solar Heater - (농산물(農産物) 건조용(乾燥用) 곡면집광식(曲面集光式) 태양열(太陽熱) 이용(利用) 장치(裝置)에 관한 연구(硏究) - 제1보(第1報). 알루미늄-아크릴 필림을 이용(利用)한 태양열(太陽熱) 집열장치(集熱裝置)의 열이용(熱利用) 효율(?率) -)

  • Chun, Jae-Kun;Mok, Chul-Kyoon;Kim, Hyun-Uk
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.8-12
    • /
    • 1979
  • A cylindrical solar energy focusing collector constructed using aluminum-laminated film plastered on the acrylic plate and examined its performances under the Korean local weather conditions. The reflector surface of this collector· evidenced the reflectivity of 66.1%,which was satisfactory value that could be applicable to the solar collector for its low price and at·availability. Collector efficiency measured at the heat exchanger fluid in absorber-copper pipe black colored was 73% and the resulting natural convection of the heat transfer media (water) was recorded up to 2.82 cm/sec. The overall efficiency of the solar heater in operation was 28.6% and it was correlated with the solar energy input and the temperature elevation difference gained.

  • PDF

Thermo-hydraulic Modeling in Fault Zones (단층대에서의 열-수리적 거동 모델링)

  • Lee, Young-Min;Kim, Jong-Chan;Koo, Min-Ho;Keehm, Young-Seuk
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.609-618
    • /
    • 2009
  • High permeable faults are important geological structures for fluid flow, energy, and solute transport. Therefore, high permeable faults play an important role in the formation of hydrothermal fluid (or hot spring), high heat flow, and hydrothermal ore deposits. We conducted 2-D coupled thermal and hydraulic modeling to examine thermohydraulic behavior in fault zones with various permeabilities and geometric conditions. The results indicate discharge temperature in fault zones increases with increasing fault permeability. In addition, discharge temperature in fault zones is linearly correlated with Peclet number ($R^2=0.98$). If Peclet number is greater than 1, discharge temperature in fault zones can be higher than $32^{\circ}C$. In this case, convection is dominant against conduction for the heat transfer in fault zones.

A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages (암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.442-453
    • /
    • 2013
  • A large-scale high-temperature thermal energy storage(TES) was numerically modeled and the heat loss through storage tank walls was analyzed using a commercial code, FLAC3D. The operations of rock cavern type and above-ground type thermal energy storages with identical operating condition were simulated for a period of five consecutive years, in which it was assumed that the dominant heat transfer mechanism would be conduction in massive rock for the former and convection in the atmosphere for the latter. The variation of storage temperature resulting from periodic charging and discharging of thermal energy was considered in each simulation, and the effect of insulation thickness on the characteristics of heat loss was also examined. A comparison of the simulation results of different storage models presented that the heat loss rate of above-ground type TES was maintained constant over the operation period, while that of rock cavern type TES decreased rapidly in the early operation stage and tended to converge towards a certain value. The decrease in heat loss rate of rock cavern type TES can be attributed to the reduction in heat flux through storage tank walls followed by increase in surrounding rock mass temperature. The amount of cumulative heat loss from rock cavern type TES over a period of five-year operation was 72.7% of that from above-ground type TES. The heat loss rate of rock cavern type obtained in long-period operation showed less sensitive variations to insulation thickness than that of above-ground type TES.