• Title/Summary/Keyword: Heat distribution

Search Result 2,932, Processing Time 0.035 seconds

Air-water two-phase distribution in an aluminum parallel flow heat exchanger header having different inlet orientations (유입 방향에 따른 알루미늄 평행류 열교환기 헤더내 공기-물 2 상류 분지 실험)

  • Kim, Nae-Hyun;Ham, Jung-Ho;Park, Tae-Kyun;Kim, Do-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2108-2112
    • /
    • 2007
  • The air and water flow distribution are experimentally studied for a round header-ten microchannel tube configuration. Three different inlet orientations (parallel, side, normal) were investigated. Tests were conducted with downward flow configuration for the mass flux from 70 to 130 kg/$m^2s$, quality from 0.2 to 0.6, non-dimensional protrusion depth (h/D) from 0.0 to 0.5. It is shown that, for almost all the test conditions, normal inlet yielded the best flow distribution, followed by side and parallel inlet. Possible reasoning is provided using flow visualization results.

  • PDF

The Computer Simulation of the Temperature Distribution on the Superconducting thin-film by Moving Quenching-Field (이동 Quenching 자계시 컴퓨터 시뮬레이션에 의한 초전도 박막에서의 온도분포해석)

  • Kang, Jung-Sun;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.115-118
    • /
    • 1991
  • The temperature distribution on the superconducting thin-film is analyzed as moving constant field is applied above upper critical field. The distribution of magnetic field is derived in the normal spot. Governing equation is obtained with the help of the equation of conservation of energy. The temperature distribution and the heat dissipation are obtained through computer simulation by the method of numerical analysis. Maximum temperature is occured in the most right side inside normal spot. The temperature is increased abruptly inside the normal spot, and decreased more gradually outside normal spot in the direction of moving field as velocity is increased. Increasing the velocity rather than increasing magnitude of the normal spot and the applied field makes maximum temperature larger. Heat dissipation is affected by the velocity rather than the magnitude of normal spot and the applied field.

  • PDF

The Study on the Temperature Distribution for 154kV Power Transformers (154kV 전력용 변압기의 온도분포에 관한 연구)

  • Woo, Jung-Wook;Koo, Kyo-Sun;Kwak, Joo-Sik;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

A Study for Improvement of Temperature Distribution in Plunger Surface Cooling (브라운관용 플런저 냉각표면의 온도분포 개선을 위한 연구)

  • Kwak, Kyung-Min;Park, Ji-Yeol;Bai, Cheol-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.126-133
    • /
    • 2008
  • The main objective of the present study is to achieve linear temperature distribution of cooling surface of plunger. K type thermocouples are attached at the surface of plunger to measure temperature. Nozzle and insulating material are inserted in the pin hole of the plunger for this study. Cooling water flow enters at one nozzle and leaves at three nozzles. Flow through nozzle can be activated in the pin hole, temperature of hot point around hole is decreased. Meanwhile, insulating material blocks off heat transfer, temperature of cold point around hole is increased. By combination of nozzle and insulation, heat transfer of hole is controlled effectively, as result its, temperature of plunger surface shows linear temperature distribution.

An Analytical Solution for Transient Temperature Distribution in Fillet Arc Welding Including the Effect of Molten Metal (용착 금속을 고려한 필릿 용접에서 온도 분포 예측을 위한 해석적 모델)

  • 정선국;조형석
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.116-124
    • /
    • 1995
  • This paper presents an analytical solution to predict the transient temperature distribution in fillet arc welding including the effect of molten metal. The solution is obtained by solving a transient three-dimensional heat conduction equation with convection boundary conditions on the surfaces of a plate, and mapping the infinite plate onto the fillet weld geometry with energy equation. The electric heat input on the fillet weld and on the infinite plate is assumed to have a combination of two bivariate Gaussian distribution. To check the validity of the solution. FCA welding experiments were performed under various welding conditions. The actual isotherms of the weldment cross-sections at various distances from the arc start point are compared with those of simulation result.

  • PDF

Thermal Distribution of Bi-Te Thermoelectric Module with the thickness of Polymer Sheet (고분자 필름의 두께변화에 따른 Bi-Te계 열전모듈의 열분포 특성)

  • Byeon, Jong-Bo;Kim, Bong-Seo;Park, Su-Dong;Lee, Hui-Ung;Kim, Yeong-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.85-86
    • /
    • 2005
  • In case of attaching thermoelectric module and heat source, the polymer sheet is attached on the $Al_2O_3$ plate, which is cooling side of thermoelectric module, in order to enhance mechanical safety of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD analyses was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analyses, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

Thermal Characteristics and Heatsink Modeling. for IGBT (IGBT의 열 특성 및 히트싱크 모델링)

  • Ryu, Se-Hwan;Bea, Kyung-Kuk;Shin, Ho-Chul;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.172-173
    • /
    • 2007
  • As the power density and switching frequency increase, thermal analysis of power electronics system becomes imperative. The thermal analysis provides valuable information on the semiconductor rating, long-term reliability. In this paper, thermal distribution of the Non Punchthrough(NPT) Insulated Gate Bipolar Transistor has been studied. For analysis of thermal distribution, we obtained experimental and simulation results by using finite element simulator, Ansys and by using photographic infrared thermometer, we compared experimental date with simulation result. and got good agreement. Also this paper provided thermal distribution of IGBT connected to heat sinks. and this results will be good information to design optimal heat sink for IGBT.

  • PDF

Research on the Output Characteristic of Thermoelectric Module according to the thickness variation of Polymer Pad (고분자 필름의 두께변화에 따른 열전소자의 출력 특성변화에 관한 연구)

  • Jang, Ho-Sung;Kim, Jae-Jung;Kim, In-Kwan;Kim, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.976-981
    • /
    • 2006
  • In case of attaching thermoelectric module and heat source, the polymer pad is attached on the $Al_2O_3$ plate, which is cooling side of thermoelectric module, in order to enhance mechanical safety of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

Flow performance of cryomodules in C-ADS Injector II

  • WAN, Yu-Qin;HAN, Yan-Ning;Zhang, Jun-Hui;Li, Chao
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.74-78
    • /
    • 2022
  • Two β=0.10 cryomodules are required for the China Accelerator Driven Subcritical System (C-ADS) injector II accelerator. Flow design is of great importance in the performance of cryomodules, including thermal design, flow distribution, pressure drop and so on. This paper will study convection heat transfer of helium and relation among the pipe diameter, mass flow rate and Reynolds number. Furthermore, the influence of flow geometries on pressure drop and flow distribution will also be done. It was found that the theoretical flow distribution were in good agreement with the experimental data.

Analysis of Relationship between the Spatial Characteristics of the Elderly Population Distribution and Heat Wave based on GIS - focused on Changwon City - (GIS 기반 노인인구 분포지역의 공간적 특성과 폭염의 관계 분석 - 창원시를 대상으로 -)

  • SONG, Bong-Geun;PARK, Kyung-Hun;KIM, Gyeong-Ah;KIM, Seoung-Hyeon;Park, Geon-Ung;MUN, Han-Sol
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.68-84
    • /
    • 2020
  • This study analyzed the relationship between spatial characteristics and heat waves in the distribution area of the elderly population in Changwon, Gyeongsangnam-do. For analysis, the Statistics Census data, the Ministry of Environment land cover, Landsat 8 surface temperature, and the Meteorological Agency's heat wave days data were used. The spatial characteristics of the distribution of the elderly population was classified into 5 types through K-mean cluster analysis considering the land use types. The characteristics of the elderly population by spatial type were higher in the urbanized type(cluster-3), but the proportion of the elderly population was higher in the agricultural and forest area types(cluster-1, cluster-2). In the characteristics of the surface temperature and the heat wave days, the surface temperature was the highest in the urban area, but heat wave days were the highest in the rural area. As a result of analyzing the heat wave characteristics according to the spatial type of the distribution area of elderly population, cluster-2 with the largest area in agricultural areas was highest at 15.95 days, and cluster-3 with a large area in urbanized types was the lowest at 9.41 days and 9.18 days. In other words, the elderly population living in rural areas is more exposed to heat waves than the elderly population living in urban areas, and the damage is expected to increase. The results of this study could be used as basic data to prepare various policy measures for effective management and prevention of vulnerable areas in summer.