• Title/Summary/Keyword: Head neck

Search Result 4,566, Processing Time 0.042 seconds

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Comparison of $Na^+/I^-$ Symporter Expression Rate in Malignant and Benign Thyroid Diseases: Immunohistochemical Study (악성 및 양성 갑상선 질환의 조직에서 면역조직학적 검사법에 의한 $Na^+/I^-$ symporter의 발현율 비교)

  • Kang, Do-Young;Jeong, Young-Jin;Lee, Kyung-Eun;Park, Heon-Soo;Yoo, Young-Hyun;Roh, Mee-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Purpose: Previous studies have not showed consistent results for the level of expression of sodium/iodide symporter (NIS) in thyroid diseases, especially malignant tumor. We undertook this study to evaluate the distribution of NIS expression in malignant thyroid diseases and compare with that in benign thyroid disease. Materials and Methods: Total patients were 119 cases (Men 15, $48{\pm}13$ yrs). Total number of samples were 205 pieces. In malignant thyroid disease, there were 153 samples: 90 in papillary carcinoma, 4 in follicular carcinoma, 2 in medullary carcinoma and 57 in metastatic lymph node. In benign thyroid disease, there were 52 samples: 36 in goiter/cyst, 11 in thyroiditis and 5 in follicular adenoma. Using immunohistochemical methods, we probed 205 samples with monoclonal anti-NIS Ab. Grading of staining was stored as 0 (negative or absent), 1 (weakly positive), 2 (moderately positive) or 3 (strongly positive). Expression rate (ER) of NIS positivity in individual disease entity was expressed as percentage of total number divided by number in 2 plus 3 grade. Results: ERs of malignant thyroid diseases were 63% in papillary carcinoma, 81% in metastatic lymph node, 71% in follicular carcinoma and 100% in medullary carcinoma. ERs of benign thyroid disease were 53% in goiter/cyst, 64% in thyroiditis and 40% in follicular adenoma. ER of malignant thyroid diseases was higher than benign thyroid diseases (71% vs 54%). Grading of NIS expression in papillary carcinoma or goiter/cyst was heterogeneously distributed in considerable cases. Normal tissue also showed heterogeneous distribution of NIS expression, which was not correlated with that of primary lesion. Conclusion: In papillary thyroid carcinoma, distribution of NIS expression was heterogeneous and increased, and not different compared with that of benign thyroid disease.

Mitochondrial DNA Mutation (3243A→G,1555A→4G,7445A→G) in Noise-Induced (소음성 난청에서의 Mitochondrial DNA A3243G, A1555G, A7445G 돌연변이)

  • Hong Young-Seoub;Nishio Hisahide;Lee Myeong-Jin;Kwak Ki-Young;Hwang Chan-Ho;Shin Dong-Hoon;Kwak Jong-Young;Lee Yong-Hwan;Kim Jong-Min;Kim Joon-Youn
    • Journal of Life Science
    • /
    • v.14 no.6 s.67
    • /
    • pp.913-919
    • /
    • 2004
  • Mitochondrial DNA mutations have been reported in recent years in association with sensorineural hering loss. The purpose of this study is to identify the association between the noise-induced sensorineural hearing loss and the A to G mutation at nucleotide 3243, 1555, 7445 of mitochondrial DNA. Study subjects were established by history and chart review, and audiological and clinical data were obtained. Blood was sampled from 214 normal controls, 102 noise-induced hearing loss, and 28 sensorineural hearing loss. The DNA of these individuals were extracted, and mitochondrial DNA fragments were analyzed by polymerase chain reaction. Subsequently, the coding sequence of mitochondrial DNA 3243, 1555, 7445 were sequenced, and compared to the normal sequence, and all sequence variations were analyzed by restriction enzymes. Mitochondrial DNA mutations $(3243A{\rightarrow}G,\;1555A{\rightarrow}4G,\;7445A{\rightarrow}G)$ were not detected by polymerase chain reactions in any patients with noise-induced hearing loss, sensorineural hearing loss, and normal controls. The DNA sequencing of PCR products did not revealed an A to G substitution at nucleotide 3243, 1555, 7445 of mitochondrial DNA. The noise-induced sensorineural hearing loss was not associated with mitochondrial DNA mutation $(3243A{\rightarrow}G,\;1555A{\rightarrow}4G,\;7445A{\rightarrow}G)$.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

"A Study on Hebrews Clothing in the Old Testament" - Especially on Hair Styles, Headgears, Footwear and Personal Ornaments - (구약성서(舊約聖書)에 나타난 히브리인의 복식(服飾) - 두식(頭飾), 신발 및 장신구(裝身具) 중심(中心)으로 -)

  • Park, Chan-Boo
    • Journal of the Korean Society of Costume
    • /
    • v.10
    • /
    • pp.63-80
    • /
    • 1986
  • The Old Testament cotains mention of the history of creation and clothing in ancient Hebrew. This study dealt with Hebrew dress customs especially aimed at the manners of their hair styles, headgears, footwear and personal ornaments. References are Korean Revised Version, English King James Version and Revised Standard Version. There is little mention of hair styles and headgears in the Old Testament. Some sort of turban was worn by priests, and soldiers protected themselves with helmets, but most Israelitish men went bareheaded except on special occasions and often wear simple headbands. It was more common for women to use headwear of some type-turbans, scarves, and veils concealing the face. The veil was the distinctive female wearing apparel. All females, with the exception of maidservants and women in a low condition of life, wore a veil. It was the custom for women to wear a veil entirely covering their head in the public. Through most of the Old Testament periods long and thick hair was admired on men and women alike. The Hebrews were proud to have thick and abundant long hair, and they gave much attention to the care of their hair. The caring of hair was deeply related to their rituals. Nazirites never took a razor to their hair during his vow-days, but instead let it grow long, as an offering to God. Men would not cut their beards, but allow them to grow long. The Israelites' standard footwear was a pair of simple leather sandals. This was one of the items of clothing not highly prized. In a colloquial saying of the time, a pair of shoes signified something of small value, and to be barefoot except in times of mourning or on holy place, was a sign either of extreme poverty or humiliation, as in the case of war prisoners. Because precious stones were not mined in the Palestine-Syria region, Hebrews imported them from foreign country. They were consumer-to a large degree limited by their very modest standard of living-but not producers. Hebrews liked the precious stones and were motivated to acquire and wear jewels. Besides their use for adornment and as gifts, the precious or semiprecious stones were regarded by Jews of property. The Hebrews were not innovators in the field of decorative arts. The prohibition of the Law against making any "graven image" precluded the development of painting, sculpture, and other forms of representational art. Jewish men did not indulge in extravagances of dress, and there was little ornamentation among them. Men wore a signet ring on their right hand or sometimes suspended by a cord or chain around the neck. The necklaces, when worn by a male, also bore any symbol of his authority. Bracelets were extremely popular with both men and women, men usually preferring to wear them on their upper arms. The girdle was a very useful part of a man's clothing. It was used as a waist belt, or used to fasten a man's sword to his body, or served as a pouch in which to keep money and other things. Men often carried a cane or staff, which would be ornamented at the top. Among the women there was more apt to be ornamentation than among the men. Hebrew women liked to deck themselves with jewels, and ornamentation of the bride were specially luxurious and numerous. They wore rings on their fingers or On toes, ankle rings, earrings, nosering, necklace, bracelets. Their shapes were of cresent, waterdrops, scarab, insect, animal or plant. Sometimes those were used as amulets. They were made of ceramics, gold, silver, bronze, iron, and various precious stones which were mostly imported from Egypt and Sinai peninsular. Hebrews were given many religious regulations by Moses Law on their hair, headgears, sandals and ornamentation. Their clothing were deeply related with their customs especially with their religions and rituals. Hebrew religion was of monotheism and of revealed religion. Their religious leaders, the prophets who was inspired by God might need such many religious regulations to lead the idol oriented people to God through them.

  • PDF

Molecular Diagnosis of Streptococcus pneumoniae in Middle Ear Fluids from Children with Otitis Media with Effusion (삼출성 중이염 소아의 중이액에서 폐구균의 분자적 진단)

  • Byun, Sung Wan;Kim, Han Wool;Yoon, Seo Hee;Park, In Ho;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.106-112
    • /
    • 2015
  • Purpose: The long-term administration of antibiotics interferes with bacterial culture in the middle ear fluids (MEFs) of young children with otitis media with effusion (OME). The purpose of this study is to determine whether molecular diagnostics can be used for rapid and direct detection of the bacterial pathogen in culture-negative MEFs. Methods: The specificity and sensitivity of both polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) to the lytA gene of Streptococcus pneumoniae were comparatively tested and then applied for pneumococcal detection in the clinical MEFs. Results: The detection limit of the PCR assay was approximately $10^4$ colony forming units (CFU), whereas that of LAMP was less than 10 CFU for the detection of S. pneumoniae. Both PCR and LAMP did not amplify nucleic acid at over $10^6$ CFU of H. influenzae or M. catarrhalis, both of which were irrelevant bacterial species. Of 22 culture-negative MEFs from children with OME, LAMP positivity was found in twelve MEFs (54.5%, 12/22), only three of which were PCR-positive (25%, 3/12). Our results showed that the ability of LAMP to detect pneumococcal DNA is over four times higher than that of PCR (P<0.01). Conclusions: As a high-resolution tool able to detect nucleic acid levels equivalent to <10 CFU of S. pneumoniae in MEFs without any cross-reaction with other pathogens, lytA -specific LAMP may be applied for diagnosing pneumococcus infection in OME as well as evaluating the impact of a pneumococcal conjugate vaccine against OME.

Immunohistochemical and Immunogold Electron Microscopic Studies on Effects of Cis-platin on the Ciliogenesis of Rat Oviducts (Cis-Platin이 흰쥐 난관의 섬모형성에 미치는 영향에 대한 면역조직학적 및 면역도금법에 의한 전자현미경적 연구)

  • Kim, Jin-Kook;Kim, Won-Kyu;Paik, Doo-Jin;Chung, Ho-Sam
    • Applied Microscopy
    • /
    • v.30 no.1
    • /
    • pp.45-59
    • /
    • 2000
  • Cis-platin is a widely used anticancer drug against certain solid tumors such as malignant ovarian tumor, malignant carcinoma of head and neck, bladder cancer and cervical cancer of uterus, and its major mechanism of action is inhibition of DNA synthesis of the tumor cell. To investigate the inhibitory effects of cis-platin on the ciliogensis of the ciliated cells in the mucosa of oviduct, the author pursued the alterations of $\alpha-tubulin$, which is the main constituent of the microtubles in cilia, after cis-platin treatment. To eliminate the possible variations due to ovarian cycle, female Spargue-Dawley rats ($150\sim200gm$ in B.W.) were pretreated with estradiol benzoate (20 mg/kg, once a day, for 4 consecutive days). Animals were administrated with cis-platin (6 mg/kg, i.p.) and sacrificed at 1day, 3days, 5days and 7days after treatment, respectively. Immunohistochemistry for $\alpha-tubulin$ using mouse anti-rat $\alpha-tubulin$ monoclonal antibody as primary antibody was done. Immunogold electronmicroscopy for intracellular distributions of $\alpha-tubulin$ was also performed with same primary antibody and Goat anti- mouse IgM which is preconjugated with gold particles of 15 nm as secondary antibody. The results obtained were as follows; 1. Strong immunoreactivity of $\alpha-tubulin$ was observed in ciliated cells of oviducts at 1, 3 and 5 days after estradiol pretreatment. 2. Weak immunoreactivity of $\alpha-tubulin$ was observed in ciliated cells of oviducts at 1 and 3 days after cis-platin treatment but it was recovered to strong immunoreactivity in 5 days 3. In immunogold electronmicroscopy, density of gold particles for $\alpha-tubulin$ reactions was decreased in apical cytoplasm, but few changes were observed in basal body or cilia at 1 and 3 days after cis-platin treatment. From these above results, it is indicated that synthesis of $\alpha-tubulin$ in ciliated cells of rat oviduct is inhibited by cis-platin treatment.

  • PDF

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Study on the Environmental Factors and Symptoms of VDT Syndrome (VDT 증후군의 환경적 요인과 증상에 대한 연구)

  • Jeong, Seunghui;Lee, Seon Young;Eu, Sun Mi;Kim, Douk-Hoon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2009
  • Purpose: Recently incidence of VDT syndrome has gradually increased as extensive use of computers. VDT syndrome reported by VDT workers include musculoskeletal disorder, neuropsychiatric disoders and eye symptoms such as eye strain, tired eyes, irritation and blurred vision. The environmental factors of VDT syndrome include electromagnetic waves, size, brightness and lighting of computer screen, height of a monitor and a worktable, working hours, kind of task, distance between screen and workers, indoor humidity and temperature, indoor air contamination and ventilation. In this study, we investigated the environmental factors related to body symptoms and health effects included in VDT syndrome. Methods: Study subjects were total 120 persons (54 male, 66 female) with age from 19 to 28. We surveyed the body symptoms and physical discomfort when doing an activity in a short distance such as reading book or paper, computer work. The questionnaire included main body symptoms, self-consciousness symptoms of eye, satisfaction of working environment, pain of the wrist when using keyboard and mouse. Results: Most of people (70%) felt physical pain from long time work of computer, paper, electrical apparatus. They mainly complained pain of neck and low back (57.1%), eye (45.2%) and head (31%). With the environmental factors, 78.3% of the subjects complaint pain of eye from inappropriate illumination. Most of the symptoms included 'eye fatigue'(38.3%), 'dryness of eye'(31.9%) and 'blurred vision'(23.7%). Subjects in this study complained discomfort of their chairs and most of them experienced pain in the wrist when using keyboard or mouse. Conclusions: When people use electrical apparatus or work with paper, people would get their eye fatigue and feeling of physical fatigue because of not harmonizing various environmental factors such as light, space, posture, worktable with theirselves. Therefore, workers should develop preventive method such as self-control of adequate break time to avoid fatigue while VDT work. Work environment should be changed to ergonomic design for optimal visual environment to prevent musculoskeletal disorder through constant research.

  • PDF