On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT)  

Bak, Jin-O (Department of Radiation Oncology, College of Medicine, Chung-Ang University)
Jeong, Kyoung-Keun (Yonsei University College of Medicine)
Keum, Ki-Chang (Yonsei University College of Medicine)
Park, Suk-Won (Department of Radiation Oncology, College of Medicine, Chung-Ang University)
Publication Information
Radiation Oncology Journal / v.24, no.4, 2006 , pp. 294-299 More about this Journal
Abstract
$\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.
Keywords
IGRT; CBCT; Set-up error;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hurkmans CW, Remeijer P, Lebesque JV, et al. Set-up verification using portal imaging: review of current clinical practice. Radiother Oncol 2001;58:105-120   DOI   ScienceOn
2 Maria AH, Kristy KB, Cynthia E, et al. Assessment of residal error in liver position using kV Cone-Beam computed tomography for liver cancer high-precision radiation therapy. Int J Radiat Oncol Biol Phys 2006;66:610-619   DOI   ScienceOn
3 Moseley DJ, White E, Haycocks T, et al. Comparison of implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate [Abstract]. Int J Radiat Oncol Biol Phys 2004;60:S229   DOI
4 Langen KM, Zhang Y, Andews RD, et al. Initial Experience with megavoltage (MV) CT guidance for dailu prostate alignments. Int J Radiat Oncol Biol Phys 2005;62:1517-1524   DOI   ScienceOn
5 Van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 2004;14:52-64   DOI   ScienceOn
6 Ekberg L, Holmberg O, Wittgren L, et al. What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer. Radiother Oncol 1998; 48:71-77   DOI   ScienceOn
7 Tinger A, Michalski JM, Cheng A, et al. A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer. Int J Radiat Oncol Biol Phys 1998;42:213-221