• Title/Summary/Keyword: Head movements

Search Result 186, Processing Time 0.024 seconds

Effects of whole body movements in using virtual reality headsets on visually induced motion sickness (전신 움직임을 요구하는 컨트롤러가 가상현실 디바이스에서 시지각과 가상현실 멀미에 끼치는 영향)

  • Kim, Sung-ho;Shin, Dong-Hee
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.283-291
    • /
    • 2017
  • Though new body movement based input system immerged in Virtual Reality (VR), VR still has a visually induced motion sickness (VIMS) problem to be accepted for users. VIMS are caused by changes in visually perceived movement that discord with vestibular system's sense of movement. Not only Head-body movements, but also hand gestures to make commands and torso movement can affect visual movement perception by enhancing immersion and its psychological product; presence. The question arises does whole body movement and hand gesture to make commands are more dominant to arousal, presence, and VIMS? To address this question, we conducted "2 (IV1; head-body movements only vs. whole body movements) * 1" between subject design experiment. The results showed that significant effect on whole body movements and arousal, marginally significant effect on presence. Eyewear usage was a moderator between hand gesture and presence relationship.

The Coordination and Contribution of Body Segments during Functioning (기능에서 신체분절의 협응과 기여)

  • Chae, Jung-Byung
    • PNF and Movement
    • /
    • v.15 no.1
    • /
    • pp.13-25
    • /
    • 2017
  • Purpose: This study investigated the coordination and contribution of body segments during functioning. Methods: The relevant literature related to body segments and function were reviewed. Results: Efficient control of function is considered with regard to a participant's ability to perform a sequence of movements in body segments, which progresses from the head to the arm, trunk, pelvis, and leg segments. Each segment performs a specific role, which environment explorer using visual information for the head, reaching and grasping for the arms, a stabilizer for the trunk, and the distribution of COM in the pelvis and leg. Conclusion: During any of the movements, the momentum generated by the proximal segments is transferred to the adjacent distal segments in an appropriate sequence. In assessing function for clinical intervention strategies, the segment coordination, segment sequence, transfer of the center of body mass, asymmetrical ratio, muscle activity, and compensatory strategies should be considered.

A Study on Effects of Agent Movement on User’s Impression

  • Yamazaki, Tatsuya
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1886-1888
    • /
    • 2002
  • Non-verbal information plays an important role not only in human-to-human communications but also in human computer interaction. In this paper, we examine effects of human-like agent's primitive movements on user's impression, where the human-like agent's primitive movements include eye, mouth, and head. SD (Semantic Differential) method was used for evaluation, and two factors were extracted as a result of the factor analysis. It is found that the first factor influenced the user's impression particularly.

  • PDF

Heart Rate Measurement Combining Motion and Color Information

  • Lomaliza, Jean-Pierre;Park, Hanhoon;Moon, Kwang-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.11
    • /
    • pp.1388-1395
    • /
    • 2020
  • Daily monitoring of the heart rate can facilitate detection of heart-related diseases in their early stages. Therefore, providing an easy-to-use and noninvasive heart rate monitoring system has been a very popular research topic in the field of healthcare. One of good candidate methods is to use commonly available cameras and extract information that can help to estimate heart rate from a human face. Generally, such information can be retrieved using two different approaches: photoplethysmography (PPG) and ballistocardiography (BCG). PPG exploits slight color changes caused by blood volume variations during heartbeats; thus, it tends to be vulnerable to unstable lighting conditions. BCG exploits subtle head motions caused by pumped blood travelling through the carotid artery during heartbeats; thus, it is vulnerable to the voluntary head movements that are not related to heartbeats. Nevertheless, most related works use either to estimate the heart rate. In this paper, we propose to combine two approaches to be robust to challenging conditions. Specifically, we explore possible ways to combine raw signals obtained from two approaches and verify that the proposed combination shows better accuracies under challenging conditions, such as voluntary head movements and ambient lighting changes.

Head Mouse System Based on A Gyro and Opto Sensors (각속도 및 광센서를 이용한 헤드 마우스)

  • Park, Min-Je;Yoo, Jae-Ha;Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.70-76
    • /
    • 2009
  • We proposed the device to control a computer mouse with only head movements and eye blinks so that disabilities by car or other accidents can use a computer. The mouse position were estimated from a gyro-sensor which can measure head movements, and the mouse events such as click/double click were from opto sensors which can detect the eyes flicker, respectively. The sensor was mounted on the goggle in order not to disturb the visual field. There was no difference in movement speed between ours and a general mouse, but it required 3$\sim$4 more times in the result of the experiment to evaluate spatial movements and events detection of the proposed mouse because of the low accuracy. We could eliminate cumbersome work to periodically remove the accumulated error and intuitively control the mouse using non-linear relative point method with dead zones. Optical sensors are used in the event detection circuitry designed to remove the influence of the ambient light changes, therefore it was not affected in the change of external light source.

The Effect of Forward Head Posture and Tension Type Headache on Neck Movement: For Office Worker

  • Kim, In-Gyun;Lee, Sang-Yeol
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.4
    • /
    • pp.108-111
    • /
    • 2018
  • Purpose: This study examined the effects of the forward head posture and tension type headache on neck movement among office workers. Methods: The subjects were 6 male and 21 female patients composed of a forward head posture group, forward head posture group with a tension type headache and a normal group. Each group consisted of 2 males and 7 females. The cranio-vertebral angle of the head and the angle of motion of the neck were measured. SPSS 23.0 was used for data analysis and one-way ANOVA was performed for the mean comparison of the neck movements in the three groups. Results: The participants had a limitation in the movement of all necks between the forward head posture group and forward head posture with tension type headache group compared to the normal subjects. The forward head posture with tension headache group had limited neck extension and lateral bending compared to the forward head posture group. Conclusion: Office workers have limitations in the movement of the neck when they are accompanied by forward head posture and tension headache. In particular, when accompanied with a tension headache, there is a restriction on the neck extension and side bending. This study is expected to provide basic data for the relief of tension headache and the treatment of forward head posture in office workers.

Movement Patterns of Head and Neck in Proprioceptive Neuromuscular Facilitation (고유수용성 신경근 촉진법의 두부·경부 운동 패턴)

  • Bae, Sung-soo;Kim, Sang-soo
    • PNF and Movement
    • /
    • v.3 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • Objective : The purpose of this study was conducted to find correct head and neck patterns, manual contact. verbal commands with proprioceptive neuromuscular facilitation(PNF). Method : This is a literature study with books, seminar note and book for PNF international course. Result : Keep the information of the biomechanics and neural science in head and neck patterns and emphasize that manual contact, verbal commands and visual stimulus. Manual contacting for movement guide and stability of the $C_0/C_1$ verbal command and visual stimulus for correcting of the $C_0/C_1$ movements. Conclusion : In reminder for PNF learning, begin with head and neck and upper trunk patterns. In that time, Knott and Voss(1968) had not enough information about biomechanic movement components and neural science movement components. But Knott and Voss(1968) emphasized that head and neck patterns relate with trunk, upper extremities and lower extremities directly. Alar ligaments are relaxed with the head in neutral and taut in flexion. Axial rotation of the head and neck tightens both alar ligaments. The right upper and left lower portions of the alar ligament limit left lateral flexion of the head and neck. Therefore, head and neck patterns has to be modify. When head moving, eye and vestibular stimulus will be change. During head and neck patterns, must be consider about stimulus of eye system and vestibular system also.

  • PDF

Mechanical Analysis of golf driving stroke motion (골프드라이빙 스트로크시 역학적 분석)

  • Park, Kwang-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.205-219
    • /
    • 2002
  • This research seeks to identify the plantar pressure distribution graph and change in force in connection with effective golf drive strokes and thus to help ordinary golfers have appropriate understanding on the moving of the center of weight and learn desirable drive swing movements. To this end, we conducted surveys on five excellent golfers to analyze the plantar pressure applied when performing golf drive strokes, and suggested dynamic variables quantitatively. 1) Our research presents the desire movements as follows. For the time change in connection with the whole movement, as a golfer raises the club head horizontally low above ground from the address to the top swing, he makes a semicircle using the left elbow joint and shaft and slowly turns his body, thus lengthening the time. And, as the golfer twists the right waist from the middle swing to the impact with the head taking address movement, and does a quick movement, thus shortening the time. 2) For the change in pressure distribution by phase, to strike a strong shot with his weight imposed from the middle swing to the impact, a golfer uses centrifugal force, fixes his left foot, and makes impact. This showed greater pressure distribution on the left sole than on the right sole. 3) For the force distribution graph by phase, the force in the sole from the address to halfway swing movements is distributed to the left foot with 46% and to the right foot with 54%. And, with the starting of down swing, as the weight shifts to the left foot, the force is distributed to the left sole with 58%. Thus, during the impact and follow through movements, it is desirable for a golfer to allow his left foot to take the weight with the right foot balancing the body. 4) The maximum pressure distribution and average of the maximum force in connection with the whole movement changed as the left (foot) and right (foot) supported opposing force, and the maximum pressure distribution also showed much greater on the left sole.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF