• Title/Summary/Keyword: Head Distribution

Search Result 915, Processing Time 0.029 seconds

Geological Structure of Okcheon Metamorphic Zone in the Miwon-Boeun area, Korea (미원-보은지역에서 옥천변성대의 지질구조)

  • 강지훈;이철구
    • The Journal of the Petrological Society of Korea
    • /
    • v.11 no.3_4
    • /
    • pp.234-249
    • /
    • 2002
  • The Miwon-Boeun area in the central and northern part of Okcheon metamorphic zone, Korea, is composed of Okcheon Supergroup and Mesozoic Cheongju and Boeun granitoids which intruded it. The Okcheon Supergroup consists mainly of quartzite (Midongsan Formation), meta-calcareous rocks (Daehyangsan Formation, Hwajeonri Formation), meta-psammitic rocks (Unkyori Formation), meta-politic rocks (Munjuri Formation), meta-conglomeratic rocks (Hwanggangni Formation) in the study area, showing a zonal distribution of NE trend. Its' general trend is locally changed into NS to EW trend in and around high-angle fault of NS or NW trend. This study focused on deformation history of the Okcheon Supergroup, suggesting that the geological structure was formed at least by four phases of deformation. (1) The first phase of deformation occurred under ductile shear deformation of top-to-the southeast movement, forming sheath fold or A-type fold, asymmetric isoclinal fold, NW-SE trending stretching lineation. (2) The second phase of deformation took place under compression of NW-SE direction, forming subhorizontal, tight upright fold of M trend in the earlier phase, and formed semi-brittle thrust fault (Guryongsan Thrust Fault) of top-to-the southeast movement and associated snake-head fold in the later phase. (3) The third phase of deformation formed subhorizontal, open recumbent fold through gravitational or extensional collapses which might be generated from crustal thickening and gravitational instability. (4) The fourth phase of deformation formed moderately plunging, steeply inclined kink fold related to high-angle faulting, being closely connected with the local change of NE-trending regional foliation into NS to EW direction of strike in the vicinity of the high-angle fault.

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

Efficiency Study of 2D Diode Array Detector for IMRT Quality Assurance (2D 어레이 다이오드 검출기를 통한 IMRT 계산선량의 정확성 평가 및 효용성 연구)

  • Kim, Tae-Ho;Oh, Seung-Jong;Kim, Min-Joo;Jung, Won-Gyun;Chung, Jin-Beom;Kim, Jae-Sung;Kim, Si-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • In this study, we evaluated the effect of grid size on dose calculation accuracy using 2 head & neck and 2 prostate IMRT cases and based on this study's findings, we also evaluated the efficiency of a 2D diode array detector for IMRT quality assurance. Dose distributions of four IMRT plan data were calculated at four calculation grid sizes (1.25, 2.5, 5, and 10 mm) and the calculated dose distributions were compared with measured dose distributions using 2D diode array detector. Although there was no obvious difference in pass rate of gamma analysis with 3 mm/3% acceptance criteria for the others except 10 mm grid size, we found that the pass rates of 2.5, 5 and 10 mm grid size were decreased 5%, 20% and 31.53% respectively according to the application of the fine acceptance criteria, 3 mm/3%, 2 mm/2% and 1 mm/1%. The calculation time were about 11.5 min, 4.77 min, 2.95 min, and 11.5 min at 1.25, 2.5, 5, and 10 mm, respectively and as the grid size increased to double, the calculation time decreased about one-half. The grid size effect was observed more clearly in the high gradient area than the low gradient area. In conclusion, 2.5 mm grid size is considered acceptable for most IMRT plans but at least in the high gradient area, 1.25 mm grid size is required to accurately predict the dose distribution. These results are exactly same as the precious studies' results and theory. So we confirmed that 2D array diode detector was suitable for the IMRT QA.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

An Analysis of Referrals, Nursing Diagnosis, and Nursing Interventions in Home Care - Wonju Christian Hospital Community Health Nursing Service - (가정간호 기록지 분석 - 원주기독병원 가정간호 보건활동을 중심으로 -)

  • Suh, Mi-Hae;Huh, Hae-Kyung
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.3
    • /
    • pp.53-66
    • /
    • 1996
  • Home Health Care is one part of the total health care system. It includes health care services that link the hospital to the community. While it is important for early discharge patients, home care is also important for people with chronic illnesses or handicapping conditions. In 1989 the Korean government passed a law that opened the way for formal development of home health care services beginning with education programs to certify nurses for home care, and then demonstration home care services. Part of the mandate of the demonstration projects was evaluation of home care services. This study was done in order to provide basic data that would contribute to the development of records that could be used for evaluation through a retrospective audit and to examine the care that had been given in Home Care at Wonju Christian Hospital over a twenty year period from 1974 to 1994. The purposes of the study were : to identify to characteristics of the clients who had received home care, to identify the reasons for client referrals, to identify the nursing problems of these clients, to identify the nursing care provided to these clients, and to identify differences in these areas over the twenty year period. The study was a descriptive study involving a retrospective audit of the client records. Demographic data on all clients were included : 4,171 clients from 2,564 families. Data on referrals, nursing diagnosis and nursing interventions were from even numbered records which had a patient problem list included in the record, 2,801 clients, Frequencies and ANOVA were used in the analysis. The results of the study showed that the majority of the clients were from Wonju city /county. There were more women than men related to the high number of postpartum clients(1,300). The high number of postparttum clients and newborns was also evident in the age distribution. An the number of maternal-child clients decreased over the 20 years, the mean age of the clients increased significantly. Other factors also contributed to this change ; as increasing number of clients with brain injuries or with cancer, and fewer children with burns, osteomyelitis and tuberculosis. There was a decrease in the mean number of visits and mean length of coverage, reflecting a movement towards a short term acute care model. The number of new clents dropped sharply after 1985. The reasons for this are : the development of other treatment alternatives for clients, the establishment of an active wellbaby clinic, many more options plus a decreasing number of new cases of Hansen's Disase, and insurance that allows people with burns to be kept in hospital until skin grafts are healed. Socioeconomic changes have resulted in an increase in the number of cases of cancer, stroke, head injuries following car accidents, and of diabetes. Of the 2,801 client records, 2,541(60.9%) contained a written referral but for 1,802 it contained only the medical diagnosis. The number of records with a referral requesting specific nursing care was 739(29.1%). Many family members who were identified as in need of nursing care had no written referral. Analysis of the patient problem list showed that 41.9% of the enteries were nursing diagnoses. Others incuded medical diagnosis, symptoms, and plans. The most frequently used diagnoses were alteration in nutrition, less than body requirements(115 entries), alteration in skin integrity(114), knowledge deficit(111), pain(78), self-care deficit(66), and alteration in pattern of urinary elimination(50). These are reflected in the NANDA categories for which the highest number of diagnosis was in the Exchanging pattern(446), followed by Moving(178), Feeling(136) and Knowing (115). Analysis of the frequency of interventions showed that exercise and teaching about exercise was the most frequent intervention, followed by teaching concering the need for follow-up care, checking vital signs, managing nutritional problems, managing catheters, giving emotional support, changing dressings, teaching about medication, teaching (subject not specified), teaching about diet, IM and IV medications or fluid, and skin care, in that order. Recommendations included: development of a record that would allow for efficient recording of frequently used nursing diagnoses and nursing interventions: expansion of the catchment area for Home Care at Wonju Christian Hospital ; expansion of the service to provide complication prevention, rehabilitation services, and support to increase the health maintenance /health promotion of the people being served as well as providing client dentered care ; and development of a clinical record that will allow efficient data collection from records, even though the recording is done by a variety of health care providers.

  • PDF

Validity of Nursing Diagnoses Related to Difficulty in Respiratory Function (호흡기능장애와 관련된 간호진단의 타당도 조사)

  • 김조자;이원희;유지수;허혜경;김창희;홍성경
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.569-584
    • /
    • 1993
  • This study was done to verify validity of nursing diagnoses related to difficulty in respiratory function. First, content validity was examined by an expert group considering the etiology and the signs / symptoms of three nursing diagnoses - ineffective airway clearance, ineffective breathing pattern, impaired gas exchange. Second, clinical validity was examined by comparing the frequencies of the etiologies and signs / symptoms of the three nursing diagnoses in clinical case studies with the results of the content validity. This study was a descriptive study. The sample consisted of 23 experts (professors, head nurses and clinical instructors) who had had a variety of experiences using nursing diagnoses in clinical practice, and 102 case reports done by senior student nurses of the college of nursing of Y-university. These reports were part of their clinical practice in the ICU. The instrument used for this study was a checklist for etiologies and signs and symptoms based on the literature, Doenges and Moorhouse (1988), Kim, McFarland, McLane (1991), Lee Won Hee et al. (1987), Kim Cho Ja et at. (1988). The data was collected over four month period from May 1992 to Aug. 1992. Data were analyzed using frequencies done with the SPSS / PC+ package. The results of this study are summarized as follows : 1. General Characteristics of the Expert Group A bachelor degree was held by 43.5% and a master or doctoral degree by 56.5% of the expert group. The average age of the expert group was 35.3 years. Their average clinical experience was 9.3 years and their average experience in clinical practice was 5.9 years. The general characteristics of the patients showed that there were more women than men, that the age range was from 1 to over 80. Most of their medical diagnoses were diagnoses related to the respiratory. system, circulation or neurologic system, and 50% or more of them had a ventilator with intubation or a tracheostomy. The number of cases for each nursing diagnoses was : · Ineffective airway clearance, 92 cases. · Ineffective breathing pattern, 18 cases. · Impaired gas exchange, 22 cases. 2. The opinion of the expert group as to the classification of the etiology, and signs and symptoms of the three nursing diagnoses was as follows : · In 31.8% of the cases the classification of etiology was clear. · In 22.7%, the classification of signs and symptoms was clear. · In 17.4%, the classification of nursing interventions was clear. 3. In the expert group 80% or mere agreed to ‘dysp-nea’as a common sign and symptom of the three nursing diagnoses. The distinguishing signs and symptoms of (Ineffective airway clearance) were ‘sputum’, ‘cough’, ‘abnormal respiratory sounds : rales’. The distinguishing sings and symptoms of (Ineffective breathing pattern) were ‘tachypnea’, ‘use of accessory muscle of respiration’, ‘orthopnea’ and for (Impaired gas exchange) it was ‘abnormal arterial blood gas’, 4. The distribution of etiology, and signs and symptoms of the three nursing diagnoses was as follows : · There was a high frequency of ‘increased secretion from the bronchus and trachea’ in both the expert group and the case reports as the etiology of ineffective airway clearance. · For the etiologies for ineffective breathing pat-tern, ‘rain’, ‘anxiety’, ‘fear’, ‘obstructions of the tract, ca and bronchus’ had a high ratio in the ex-pert group and ‘decreased expansion of lung’ in the case reports. · For the etiologies for impaired gas exchanges, ‘altered oxygen -carrying capacity of the blood’ and ‘excess accumulation of interstitial fluid in lung’ had a high ratio in the expert group and ‘altered oxygen supply’ in the case reports. · For signs and symptoms for ineffective airway clearance, ‘dyspnea’, ‘altered amount and character of sputum’ were included by 100% of the expert group. ‘Abnormal respiratory. sound(rate, rhonchi)’ were included by a high ratio of the expert group. · For the signs and symptoms for ineffective breathing pattern. ‘dyspnea’, ‘shortness of breath’ were included by 100% of the expert group. In the case reports, ‘dyspnea’ and ‘tachypnea’ were reported as signs and symptoms. · For the sign and symptoms for impaired gas exchange, ‘hypoxia’ and ‘cyanosis’ had a high ratio in the expert group. In the case report, ‘hypercapnia’, ‘hypoxia’ and ‘inability to remove secretions’ were reported as signs and symptoms. In summary, the similarity of the etiologies and signs and symptoms of the three nursing diagnoses related to difficulty in respiratory function makes it difficult to distinguish among them But the clinical validity of three nursing diagnoses was established through this study, and at last one sign and symp-tom was defined for each diagnosis.

  • PDF

An Epidemiological Study on the Accidental Mortality in Various Industries in Busan Area (부산지역 산업인구의 사고사에 관한 역학적인 조사연구)

  • Chung, Young-Sun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.166-175
    • /
    • 1977
  • The author have performed an epidemiological study on the accidental deaths at industry from 1970 to 1975, in order to seek for the preventive measures of industrial accident with the under-standing of its cause and characteristics of the accidental deaths. The obtained results were as follows; 1. Total number of deaths for 6 years were 361 (350 males, 11 females). and the mean death rate was 33.8 per 100,000 industrial workers during 6 years. By the highest as 52.9 was in 1974 and the lowest as 13.7 in 1970. By the industry group, the death rate of Electricity, Gas and Water was 149.3, Construction 83.9 and the lowest was Manufacturing as 18.3. 2. Standardized mortality rate of the cases by the age group showed that 20-29 years old group was 43.0, 40-49 years old group 38.1, 30-39 years old group 32.0, and the lowest as 17.9 was under 19 years old group. 3. The cumulative percentage of the cases by years of service showed that under 6 months was 60.4%, under 1 year 72.9%, under 2 years 83.1%. 4. By the month of occurrence, the highest was 15.8% which occurred in August and the lowest was 5.8% in February. The highest as 19.1% was on Friday and the lowest as 11.9% on Monday by the day of a week. 5. By the causes of accident, car accidents was 28.3%, fall accidents 19.1%, accidents by a crash 9.1% in that order. By the location of injury, head was 44.6%, multiple injuries 33.0%, chest 10.5%, and back was the lowest as 1.9%. The distribution of the cases by nature of injury shelved that cerebral contusion and hemorrhage was 39.4%, fracture and dislocation 33.2%, asphyxia 8.0% in that order. 6. The cumulative percentage of the cases by the duration from injury to death showed that the injuried day was 74.2%, within 3 days after injury 88.5%, within 7 days 96.1%. Therefore most of the cases were occurred within 7 days after injury. 7. Byythe daily mean wages, most of the cases as 91.7% were under 2,000 won, and more 4,000 won was 1.6% merely.

  • PDF

Review of Remote Sensing Studies on Groundwater Resources (원격탐사의 지하수 수자원 적용 사례 고찰)

  • Lee, Jeongho
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.855-866
    • /
    • 2017
  • Several research cases using remote sensing methods to analyze changes of storage and dynamics of groundwater aquifer were reviewed in this paper. The status of groundwater storage, in an area with regional scale, could be qualitatively inferred from geological feature, surface water altimetry and topography, distribution of vegetation, and difference between precipitation and evapotranspiration. These qualitative indicators could be measured by geological lineament analysis, airborne magnetic survey, DEM analysis, LAI and NDVI calculation, and surface energy balance modeling. It is certain that GRACE and InSAR have received remarkable attentions as direct utilization from satellite data for quantification of groundwater storage and dynamics. GRACE, composed of twin satellites having acceleration sensors, could detect global or regional microgravity changes and transform them into mass changes of water on surface and inside of the Earth. Numerous studies in terms of groundwater storage using GRACE sensor data were performed with several merits such that (1) there is no requirement of sensor data, (2) auxiliary data for quantification of groundwater can be entirely obtained from another satellite sensors, and (3) algorithms for processing measured data have continuously progressed from designated data management center. The limitations of GRACE for groundwater storage measurement could be defined as follows: (1) In an area with small scale, mass change quantification of groundwater might be inaccurate due to detection limit of the acceleration sensor, and (2) the results would be overestimated in case of combination between sensor and field survey data. InSAR can quantify the dynamic characteristics of aquifer by measuring vertical micro displacement, using linear proportional relation between groundwater head and vertical surface movement. However, InSAR data might now constrain their application to arid or semi-arid area whose land cover appear to be simple, and are hard to apply to the area with the anticipation of loss of coherence with surface. Development of GRACE and InSAR sensor data preprocessing algorithms optimized to topography, geology, and natural conditions of Korea should be prioritized to regionally quantify the mass change and dynamics of the groundwater resources of Korea.

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF