• 제목/요약/키워드: Harmonics Effect

검색결과 240건 처리시간 0.03초

Buck Converter 방식을 이용한 Universal Motor 구동시의 전원측 고조파 및 EMI 특성 (Source Harmonics and EMI Characteristics of Buck Converter Driving Universal Motor)

  • 김흥성;전윤석;조영준;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.99-102
    • /
    • 1996
  • In this paper input characteristics of Buck converter to drive small capacity universal motor is analyzed about current harmonics and EMI which is due to a switching effect. And as a strategy for EMI reduction, filter is designed. As a results it is approved that buck converter is adequate method to reduce low order harmonics.

  • PDF

Effect of IPMSM d-q Axis Parameters According to Magnetic Saturation and Armature Reaction

  • Jang, Kibong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.539-544
    • /
    • 2015
  • FEA was used to analyze inductance and torque of IPMSM. Torque and inductance are analyzed on the dq-axis. It was shown that Ld and Lq have harmonic components, and magnitude as well as phase of the harmonics varies according to the current values. This paper shows the relationship between these inductance harmonics and the 6th harmonic component of torque.

가변속 구동장치의 부하측에서 발생하는 고조파 해석 (Analysis of Harmonics generated at Load of Adjustable Speed Drives)

  • 김종겸;이은웅;이동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.46-48
    • /
    • 1997
  • Induction motor control using for adjustable speed drives has caused secondary effect such as harmonics. Therefore it is considered a various countermeasures to minimize these effects. In this paper, we analyzed the influence of harmonics that is generated by the inverter device for adjustable speed drive of induction motor at the load side.

  • PDF

고조파가 몰드변압기 수명에 미치는 영향분석 (Effect of Harmonics on the Cast-Resin Transformer Life Cycle)

  • 강창섭;이홍기;이은철;윤덕량
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.118-120
    • /
    • 1996
  • We've been reported recently that increase of installing big power converting equipment which makes harmonics result in damage on transformer for incoming and load. Specially, harmonics that cause overheat and aging is severer in cast-resin transformer a kind of dr type than in oil one. The goal of this paper is to prove the process for aging of transformer that result from harmonics in according to both of theory and actual measurement on site. And we introduce diagnostic methods to estimate aging condition of cast-resin transformer in accordance with simulation.

  • PDF

Harmonic Analysis of Reactor and Capacitor in Single-tuned Harmonic Filter Application

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.239-244
    • /
    • 2011
  • Industrial power distribution system includes many kinds of non-linear loads, which produce the harmonics during energy conversion transition. The single-tuned passive filter is widely used to absorb the harmonics and attenuate its undesirable effect in the distribution system. However, the passive filter might be severely stressed, and sometimes even damaged, due to the absorption of harmonics. There is voltage rise on the capacitor when the single-turned harmonic filter is applied. When the capacitor voltage rose above the allowable limit, the expected life of the capacitor will considerably deteriorate. On the other hand, the reactor can experience the spike voltage even if the voltage and current of the capacitor are within the allowable limit, and this accumulated voltage stress of the reactor causes its premature fault. In this paper, we analyzed and compared the harmonic voltage and current of the reactor and capacitor in a single-tuned harmonic filter through the EMTP software and verified them with the experimental results.

반도체 스위칭 소자의 트리거 특성을 이용한 배터리 자동 충전회로에 관한 연구 (A study on the auto-charging circuit of the battery power units using trigger characteristics of semiconductor device)

  • 김영민;황종선;박성진;임종연;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.519-522
    • /
    • 2001
  • Recently, the battery charging technology and reducing technology of harmonics on AC input line are rising importantly according to increasing electrical facilities that it has been replaced battery with emergency power. In this study, I proposed that an auto-charging circuit of battery has low cost with simple-construction circuit, relative, harmonics reduction with diode tap-change method, high reliability of system for using characteristics of thyristor switching. In case of this circuit, convenience and reliability of maintenance of battery power units were more improved. 1 think that it is resulted in effect of prevention to shortening of battery life from over-charging and over-discharging and decrease of harmonics obstacle on AC input line.

  • PDF

배전 계통의 고조파 측정 및 DB 구축에 대한 연구 (A study on the measurement of harmonics in the distribution system and the configuration of DB)

  • 박용업;강문호;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.202-203
    • /
    • 2006
  • The equipment using the Power electronic device is recently increased in the distribution system, so power utility and customers increase in concerning about harmonics level. Accordingly, The power utility which prepares a measure for the harmonic public standard and manege process must analysis of the harmonics level and the effect on equipment interconnecting distribution system. In the past, the measurement equipment and technique is imperfect, so very difficult to investigate the harmonics and trend. But the improvement of the measurement equipment recently is possible to obtain the data realtime for harmonic analysis. In this paper, we research the measuring domestic harmonic and constructing of DB based on the IEC standard.

  • PDF

고조파 억제용 수동필터의 현장 적용화 연구 (A study on the Development and Field Application of Passive Filter for Harmonic Suppression)

  • 박한종;강창섭;이홍기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.89-91
    • /
    • 1999
  • The use of electronic power unit essentially result in serious problems by harmonics. To reduce the effect by harmonics, we propose passive filter system which can control each harmonic filters individually. So, additional devices to detect and analyze harmonics were installed to filter system. According to measured data in the field, we calculated the values of filter components and verified them by computer simulation. After installation of filter system in the field, we could reduce harmonics and improve power factor.

  • PDF

Harmonic Analysis of a Modular Multilevel Converter Using Double Fourier Series

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Ahn, Jin Hong;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.298-306
    • /
    • 2018
  • This paper presents a harmonic analysis of the modular multilevel converter (MMC) using a double Fourier series (DFS) algorithm. First, the application of DFS for harmonic calculation in the MMC is made by considering the effect of arm inductor. The analytical results are then confirmed by comparing with the simulation results of using the fast Fourier transform (FFT) algorithm. Finally, distribution of harmonics and total harmonic distortion (THD) in the MMC will be analyzed in three cases: harmonics versus number of levels of MMC, harmonics versus total switching frequency and harmonics versus modulation index. The simulation results are performed in the PSCAD/EMTDC simulation program in order to verify the analytical results obtained by Matlab programming.

A DFT Based Filtering Technique to Eliminate Decaying dc and Harmonics for Power System Phasor Estimation

  • Oh Yong- Taek;Balamourougan V.;Sidhu T.S.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.138-143
    • /
    • 2005
  • During faults, the voltage and current signals available to the relay are affected by the decaying dc component and harmonics. In order to make appropriate and accurate decisions, most of the relaying algorithms require the fundamental frequency phasor information that is immune to decaying dc effect and harmonics. The conventional Fourier ph as or estimation algorithm is affected by the presence of decaying-exponential transients in the fault signal. This paper presents a modified Fourier algorithm, which effectively eliminates the decaying dc component and the harmonics present in the fault signal. The decaying dc parameters are estimated by means of an out-of-band filtering technique. The decaying dc offset and harmonics are removed by means of a simple computational procedure that involves the design of two sets of Orthogonal digital OFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying dc component. It was also compared with the conventional mimic plus the full cycle OFT algorithm. The results indicate that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus OFT algorithms over a wide range of decay rates. In all cases, the convergence to the desired value was achieved within one cycle of the power system frequency.