• 제목/요약/키워드: Halogen Bonding

검색결과 20건 처리시간 0.035초

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA; PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA; QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도 (Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mw/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.001).

광중합형 레진으로 아말감 면에 브라켓 접착 시 전단결합강도 (Shear bond strength of orthodontic adhesive to amalgam surface using light-cured resin)

  • 조지영;이동렬;임용규
    • 대한치과교정학회지
    • /
    • 제35권6호
    • /
    • pp.443-450
    • /
    • 2005
  • 본 연구는 아말감 면에 광중합형 레진으로 교정용 브라켓을 접착시킬 경우, 광원의 차이(할로겐 광중합기와 light-emitting diode (LED) 광중합기)와 샌드블라스팅 표면처리 여부에 따른 접착제의 전단결합강도를 비교하고자 시행되었다. 발거된 소구치 30개를 대조군으로 이용하였으며 법랑질 표면을 산부식한 후 통상적인 방법으로 브라켓을 접착하였다. 60개의 다른 소구치에 아말감 충전을 하여 실험군으로 이용하였다. 두 군에서 할로겐 광중합기와 LED 광중합기를 이용하여 브라켓을 접착시키고 브라켓이 탈락될 때까지 힘을 가해 전단결합강도를 측정하였다. 실험 결과, 실험군의 전단결합강도는 약 3-5.5 MPa로 대조군(19MPa)보다 낮았다. 실험군에서 샌드블라스팅 표면처리를 한 경우, 할로겐 광중합기를 사용한 군이 LED 광중합기를 사용한 군보다 높은 전단결합강도를 보였으나 (P<0.05), 샌드블라스팅 표면처리를 하지 않은 경우에는 광원에 따라 전단결합강도에 차이를 보이지 않았다 (p > 0.05). 할로겐 광중합 군과 LED 광중합 군 모두에서 샌드블라스팅 여부에 따른 전단결합강도에 통계적으로 유의한 차이가 없었다 (p>005). 아말감 면에 광중합형 레진을 이용하여 브라켓을 접착할 경우 할로겐 광중합기와 LED 광중합기로 얻을 수 있는 접착제의 결합강도는 임상적으로 사용하기에는 낮게 나타나, 이의 증진 방법을 도모하기 위해 앞으로 더 많은 연구가 필요하리라 사료된다.

다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구 (THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES)

  • 최남기;조성훈;김선미
    • 대한소아치과학회지
    • /
    • 제38권1호
    • /
    • pp.33-41
    • /
    • 2011
  • 본 연구의 목적은 상업용으로 시판되고 있는 수종의 치과용 접착제를 세대별로 분류하여 서로 다른 광원에 노출 시켜 중합하고 접착면의 전단 강도 측정을 통해 결합강도를 비교함으로써 간접적으로 광원에 따른 접착제의 중합 양상을 알아보고 소아치과 영역에서 가장 권장할만한 치과용 접착제와 광원 종류의 조합을 알아보고자 함이다. 본 연구에서는 최근에 개발된 치과용접착제를 대상으로 다른 유형의 광원으로 중합하였을 때 영구치 상아질에 대한 결합력 비교 평가하여 임상에서 상아질결합제와 광중합 시스템의 적절한 조합을 선택하는데 도움을 주고자 시행하였으며, 실험재료로 Adper Scotchbond Multi-purpose Plus Adhesive (SM; 3M ESPE, USA), Adper Single bond 2 (SB; 3M ESPE, USA), Clearfil SE Bond (SE; Kuraray Medical Inc., Japan), Adper Prompt L-Pop (PL; 3M ESPE, USA), GBond (GB; GC Cooperation Toyko, Japan)을 이용하여 Elipar Free light 2(LED; 3M ESPE, USA), OptiLux 501 (Halogen, Kerr, USA), Flipo (PAC, LOKKI, FRA) 세 가지의 광원으로 중합하고 전단결합강도를 평가한 뒤 다음과 같은 결과를 얻었다. 1. Freelight 2로 중합하였을 때 전단결합강도는 SM이 가장 높았으며($28.22{\pm}5.56$), SB($21.68{\pm}7.44$), SE($20.13{\pm}9.88$), PL($14.18{\pm}5.88$), GB($14.30{\pm}6.81$) 순이었다. SM은 PL, GB와 유의한 차이가 있었으나 (p<0.05), SB, SE, PL, GB 간에는 차이가 없었다. 2. Optiux 501로 중합하였을 때 전단결합강도는 SM이 가장 높았으며 ($22.06{\pm}7.95$), PL($12.94{\pm}4.96$), SB($12.80{\pm}3.35$), SE($12.43{\pm}4.79$), GB($10.00{\pm}3.47$) 순이었고, SM만 유의한 차이가 있었으나 (p<0.05), 다른 군 간에는 차이가 없었다. 3. Flipo로 중합하였을 때 전단결합강도는 SM이 가장 높았으며 ($26.82{\pm}11.16$), PL($15.42{\pm}9.35$), SB($10.96{\pm}3.74$), SE($9.39{\pm}3.74$), GB($7.85{\pm}2.22$) 순이었다. SM은 SB, SE, GB 군과 유의한 차이가 있었으나 (p<0.05), 다른 군 간에는 차이가 없었다. 4. 광원에 따른 차이는 SB와 GB에서만 유의성이 있었고, 다른 결합제에서는 유의한 차이가 없었다. 광원에 따른 유의성을 나타낸 결합제 중 SB는 Freelight 2가 다른 광원에 비해 유의한 차이를 보였고 OptiLux 501과 Flipo간의 차이가 없었던 반면, GB는 Freelight 2와 Flipo 간에만 유의한 차이를 나타냈다.

Effects of a new desensitizing paste containing 8% arginine and calcium carbonate on the shear bond strength of orthodontic brackets

  • Yagci, Ahmet;Uysal, Tancan;Akinci, Hatice;Uysal, Banu
    • 대한치과교정학회지
    • /
    • 제41권2호
    • /
    • pp.121-126
    • /
    • 2011
  • Objective: The purpose of this study was to evaluate shear bond strength (SBS) and failure site location of brackets bonded to enamel with or without desensitizer application. Methods: Sixty-six freshly extracted human premolar teeth were randomly divided into 3 groups of 22. Group 1 served as the control. Desensitizer was applied to the remaining teeth at two time intervals (Group 2, bonded immediately after Pro-$Relief^{TM}$ (Colgate-Palmolive Co., New York, NY, USA) application and Group 3, bonded 30 days after Pro-$Relief^{TM}$ application with the teeth stored in artificial saliva during the 30 days). Orthodontic brackets were bonded with a light cure composite resin and cured with a halogen light. After bonding, the SBS of the brackets was tested using a universal testing device. Adhesive remnant index (ARI) scores were determined after the brackets failed. Data were analyzed with analysis of variance, Tukey's HSD, and G tests. Results: The SBS was significantly lower in Group 2 than in Groups 1 (p = 0.024) and 3 (p = 0.017). Groups 1 and Group 3 did not differ (p = 0.991). ARI scores did not differ significantly among groups. Conclusions: The Pro-$Relief^{TM}$ desensitizer agent applied immediately before bonding significantly reduces bond strength, but the SBS values still exceed the minimum 5.9 - 7.8 MPa required for adequate clinical performance. Immersing the teeth in artificial saliva for 30 days after applying the Pro-$Relief^{TM}$ desensitizer agent and before bonding increased the SBS to control levels.

본딩 웨이퍼 분석 시스템 개발 (Development of Bonded Wafer Analysis System)

  • 장동영;반창우;임영환;홍석기
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.969-975
    • /
    • 2009
  • In this paper, bonded wafer analysis system is proposed using laser beam transmission; while the transmission model is derived by simulation. Since the failure of bonded wafer stems in void existence, transmittance deviations caused by the thickness of the void are analyzed and variations of the intensity through the void or defect easily have been recognized then the testing power has been increased. In addition, large screen display on laser study has been done which resulted in acquiring a feasible technique for analysis of the whole bonding surface. In this regard, three approaches are demonstrated in which Halogen lamp, IR lamp and laser have been tested and subsequently by results comparison the optimized technique using laser has been derived.

N-Halamine을 이용한 항균 멤브레인의 특성 (Properties of Antimicrobial Membrane Using an N-Halamine Material)

  • 백지윤;김삼수;이재웅
    • 한국염색가공학회지
    • /
    • 제21권4호
    • /
    • pp.57-62
    • /
    • 2009
  • N-Halamines are compounds which have covalent bonding between nitrogen and halogen. N-Halamine materials possess strong antimicrobial properties against wide spectrum of bacteria. The aim of this study is to prepare N-halamine membranes using m-aramid and poly(vinyl alcohol) (PVA). Surface characteristics using scanning electron microscope (SEM), pore size distribution, liquid permeability and mean pore size were measured to confirm feasibility as membrane. The results indicated that increased PYA portion up to 15% in the m-aramid/PVA blend resulted in improved pore size distribution, liquid permeability as well as mean pore size. Furthermore, antibacterial efficacy of the membranes after chlorination was confirmed and the results showed that bacteria in water were inactivated.

Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING)

  • 김정윤;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.638-642
    • /
    • 2001
  • 최근에 소개된 Plasma arc lamp를 이용한 고광도 광조사기는 조사되는 광도를 크게 증가시켜 필요한 조사시간을 단축시키고자하는 연구의 결과중 하나이다. 교정 임상에서 브라켓의 접착시 고광도 광조사기를 사용하여 시술시간을 줄인다면 환자뿐만 아니라, 술자에게도 시간적이나 경제적으로 많은 도움을 줄 것이다. 이 연구의 목적은 Plasma arc light를 사용하여 접착시킨 브라켓의 치면에 대한 전단강도를 측정하고 이를 기존의 할로겐 램프를 이용한 광중합 방법과 비교해보기 위함이다. I군은 할로겐 램프를 사용하는 $XL3000^{(R)}$을 이용하여 총 50초간 광중합하였고 II군은 plasma arc lamp를 사용하는 $Flipo^{(R)}$를 이용하여 2초간 광중합하였으며 III군도 $Flipo^{(R)}$를 이용하여 총 5초간 광중합하여 전단강도 측정을 시행한 결과는 다음과 같다. 1. 세 군의 전단강도의 평균은 비슷한 수치를 나타내었다. 2. 세 군간의 통계학적 유의 차가 없었다(p>0.05).

  • PDF

가시광선용 그리즘의 제작과 성능시험 (FABRICATION AND TEST OF AN OPTICAL GRISM)

  • 이동하;송재원;윤태석
    • 천문학논총
    • /
    • 제28권3호
    • /
    • pp.75-82
    • /
    • 2013
  • An optical grism for education is fabricated and tested. It is composed of a transmission grating as dispersion element and a prism as diffraction angle compensation device. The transmission grating is Edmundoptics #49-584(spatial frequency 600 lines/mm, dimension $50mm{\times}50mm$). The prism is the fused silica type with angles ($41.3^{\circ}$, $-48.7^{\circ}$, $-90^{\circ}$). The grism device is fabricated by bonding the transmission grating and the prism with an optical adhesive. The zig for assembling the grism, telescope and camera is composed of an aluminum tube, an aluminum disk ring and a T-ring camera adaptor. The fabricated optical grism spectrograph is tested in laboratory using Halogen lamp and Neon lamp with DSLR camera. And the grism assembled with reflector telescope is tested in a field using stellar light. The results show good agreements with design parameters. The wavelength coverage range of the grism is 250 nm at the un-deviated wavelength of 506 nm. The wavelength resolution is 0.11 nm/pixel.

유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구 (MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR)

  • 이현헌;장철호;김영재;김정욱;장기택
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.62-72
    • /
    • 2007
  • 이번 실험에서는 중합수축 응력이 가장 크게 나타나는 유구치 I급 와동에서 와동벽의 위치와 중합광원의 변화에 의해 다르게 나타나는 응력의 차이를 microtensile bond strength (MTBS)를 이용하여 알아보는 것을 목적으로 하였다. 교합면 법랑질을 제거한 하악 제 2유구치 30개를 준비하여 I급 와동을 형성하였다. 제조사의 지시에 따라 상아질 접착제를 도포 후 3가지 중합광원: 할로겐 램프, 플라즈마, 발광다이오드를 이용하여 10개씩 광중합하였다. 복합레진을 한꺼번에 충전 후 각각의 중합기로 광중합하였다. 동일 치아에서 각각 치수벽과 축벽의 MTBS 측정용 시편을 제작하고 각 군을 중합광원과 와동벽 위치에 따라 할로겐 램프 - 축벽군, 할로겐 램프 - 치수벽군, 플라즈마 - 축벽군, 플라즈마 - 치수벽군, 발광다이오드 - 축벽군, 발광다이오드-치수벽군의 6개 군으로 분류하였다. 만능시험기에서 MTBS를 측정하고 파절편과 와동의 단면을 SEM을 이용하여 관찰하였다. 동일 중합광원에서 와동벽 간 비교는 T-test, 동일 와동벽에서 중합광원 간 비교는 One-way ANOVA와 Tukey's post hoc test를 이용하였고 Weibull 분포분석을 하였다. 동일 중합광원 군간 비교에서 모두 치수벽 시편의 접착강도가 축벽 시편에 비해 유의하게 높았으며 동일 와동벽 군간 비교에서 모두 중합광원에 따른 접착강도가 유의한 차이를 보이지 않았다. 축벽 시편이 치수벽 시편보다 낮은 Weibull 변수(m)를 나타내었고 SEM 관찰 결과 축벽 시편에서 보다 더 불균일한 접착이 이루어진 것을 알 수 있었다.

  • PDF

이소옥사졸과 그의 유도체들이 배위된 팔라듐(Ⅱ)과 백금(Ⅱ) 착물의 항암활성에 관한 이론적 연구 (Theoretical Study on Antitumor Activity of Palladium(II) and Platinum(II) Complexes with Isoxazole and Its Derivatives)

  • 김정성;송영대
    • 대한화학회지
    • /
    • 제42권4호
    • /
    • pp.369-377
    • /
    • 1998
  • 이소옥사졸과 그의 유도체가 배위된 팔라듐(II) 및 백금(II)착물$([M(L)_2X_2]$, M=Pd(II), Pt(II); L=isoxazole(isox), 3,5-dimethylisoxazole(3,5-diMeisox), 3-methyl, 5-phenylisoxazole(3-Me, 5-Phisox), and 4-am-ino 3,5-dimethylisoxazole(4-ADI); X=Cl, Br)의 항암활성을 분자역학(MM2)법으로 최소에너지를 갖는 구조를 구한 후 확장분자궤도함수(EHMO)법으로 조사하였다. 중심금속의 $d_x^{2-}_y^2$ 궤도함수와 할로겐 원자의 $p_x$ 궤도함수 사이의 ${\sigma}MO$ 에너지준위$(E_{{\sigma}(Pd,Pt-X)})$가 질소원자의 $p_x$ 궤도함수 사이의 ${\sigma}MO$ 에너지준위 $(E_{\sigma}(Pd,Pt-N))$보다 예외없이 더 높아서 결합이 약함을 알 수 있었다. 아울러 같은 착물에서 cis- 보다 trans-착물에서 $(E_{\sigma}(Pd,Pt-X))$ 값이 더 높아서 결합이 약함을 알았다. 또한 평면형 리간드가 배위될 경우 cis-, trans- 이성체 모두 백금착물에서보다 팔라듐착물에서 $X^-$ 이온의 이탈이 더 용이했다. 다라서 $X^-$ 이온으로 떨어져 나가는 용이성이 항암활성과 어떤 관계가 있을 것으로 생각하고 $E_{{\sigma}(Pd,Pt-N)}-E_{{\sigma}(Pd,Pt-X)}({\Delta}E_{{\sigma}(N-X)})$과 저해활성 계수인 logIA의 값를 도시하였던바 실험치와 상관 계수가 0.96인 좋은 직선성이 성립함을 알 수 있었다.

  • PDF