• Title/Summary/Keyword: Half-Bridge Inverter

Search Result 260, Processing Time 0.026 seconds

A new active common mode voltage Damper to suppress high frequency leakage current of PWM Inverter (새로운 능동형 커먼 모드 전압 감쇄기를 이용한 PWM 인버터의 고주파 누설전류 억제)

  • 구정회;이상훈;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.423-431
    • /
    • 2001
  • This paper proposes a new active common-mode voltage damper circuit that is capable of suppressing a common-mode voltage produced in the PWM VSI-fed induction motor drives. The new active common mode voltage damper is consists of a four-level half-bridge Inverter and a common mode transformer with a blocking capacitor. In order to reduce the common mode voltage and high frequency leakage current the active common mode damper applies to the PWM inverter system the compensated voltage of which the amplitude is the same as the common mode voltage and of which the polarity is opposite to the common mode voltage. Simulated using P-SPICE and experimental results show that common-mode voltage damper makes contributions to reducing a high frequency leakage current and common-mode voltage.

  • PDF

A Study on the development of Explosion-proof type's the terminal box of the ventilator with the control of wind volume and operating time (풍량 및 운전시간 제어 방폭 배풍기 인버터 단자함 개발에 관한 연구)

  • Yoo, DongJoo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.187-192
    • /
    • 2018
  • This thesis is about the study of inverter terminal boxes in a explosion proof type exhaust fan that can control wind volume and operating time. In Korea, there is no ventilator to adjust the amount of wind and operating time when working in poor conditions. The purpose of the project is to create a explosion terminal box that can control the operating time and wind speed of a suitable explosion ventilator in hazardous environments. The two explosion-proof switches allow the operation time to be driven 1 hour, 3 hours and continuous time, and the speed of the induction motor rotation was set in 3 stages at 2000 rpm, 2600 rpm and 3000 rpm to control the volume. The tested motor used a half-horsepower barrier three-phase induction motor and a full-bridge inverter to set the desired flow rate and operating time.

Low Cost and High Performance Single Phase UPS Using a Single-Loop Robust Voltage Controller

  • Ji, Jun-Keun;Ku, Dae-Kwan;Lim, Seung-Beom
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.695-701
    • /
    • 2015
  • Uninterruptible Power Supplies (UPSs) can be largely divided into the passive-standby, line-interactive and double-conversion methods. This paper proposes a double-conversion UPS with a low cost and high performance. This single phase UPS uses a single-loop robust voltage controller and 1-switch voltage doubler strategy PFC. The proposed UPS is composed of a single phase PFC, a half-bridge inverter, a battery charger and a battery discharger. Finally, the validity of proposed UPS was verified by various experimental tests.

Voltage Control of Single-Phase Half Bridge Inverter Using a Repetitive Controller (반복 제어기를 이용한 단상 하프 브리지 인버터의 전압제어)

  • Park, Jonghwa;Jo, Hyeungil;Jo, Hyunsik;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.381-382
    • /
    • 2016
  • 본 논문에서는 비례 공진 제어기와 반복 제어기를 결합한 단상 하프 브리지 인버터의 전압 제어에 대해 연구하였다. 연구결과 고조파 발생 시 전체적으로 시스템에 문제를 야기하는 것을 확인하였으며, 이러한 문제를 해결하기 위해 기본파 성분을 제어하던 기존의 비례 공진 제어기에 반복 제어기 알고리즘을 결합하였다. 그 결과 추가적으로 인버터 데드타임에 의해 발생하는 고조파를 보상하였다. 그에 따른 성능은 시뮬레이션을 통하여 비례 공진 제어기만을 사용했을 때와 비교, 분석 및 검증하여 THD가 7.91[%]에서 4.62[%]로 약 3.29[%] 감소하는 것을 확인하였다.

  • PDF

A Characteristic Analysis of DC-DC Converter linked LCC type High Frequency Resonant Inverter (LCC형 고주파 공진 인버터 링크 DC-DC 컨버터의 특성해석)

  • Nam, Seung-Sik;Ro, Chae-Gyun;Lee, Dal-Hae;Seo, Cheol-Sik;Hwang, Gye-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2007-2009
    • /
    • 1997
  • This paper proposes the LCC type high frequency resonant DC-DC converter using Power MOSFET as switching devices, and describes the characteristics and operating principles. LCC converter has the resonant capacitor instead of a source decoupling capacitor in the conventional half bridge parallel resonant converter. We performed an experiment to prove the propriety of proposed converter.

  • PDF

The optimal design of electronic ballasts for triple-type compact fluorescent lamps considering variation of ambient temperatures (주위온도를 고려한 트리플형 콤팩트 형광램프용 전자식 안정기의 최적 설계)

  • Song, Sang-Bin;Gwark, Jae-Young;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.434-436
    • /
    • 1996
  • This paper investigates the optimal design of an electronic ballast of half bridge inverter type in consideration of the variation of ambient temperatures for a 15[W] triple-type compact fluorescent lamp. The performances of electronic ballasts under different values or the capacitance ratio in the resonant tank circuit are compared with each other in the practical temperature range between 15[$^{\circ}C$] and 35[$^{\circ}C$] to determine its optimum value. As a result, the optimum value is found to be such that $C_1/C_2=10$ at which value starting of the lamp is most stable and light output reaches its maximum value with lowest variation.

  • PDF

A Novel Three-Level ZVS PWM Inverter Topology for High-Voltage DC/DC Conversion Systems with Balanced Voltage Sharing and Wider Load Range (차단전압 균형과 넓은 부하범위를 갖는 새로운 3-레벨 ZVS PWM DC-DC 컨버터)

  • 송인호;유상봉;서범석;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.71-75
    • /
    • 1996
  • As the Three-level ZVS PWM DC-DC converter operates likewise full-bridge ZVS PWM DC-DC converter and the blocking voltage of each switching device is a half of the DC-link voltage, it is suitable for the high imput voltage applications. However, it has some problems as follows; The blocking voltage of each devices is unbalanced and it causes the power losses of the inner switching devices to be increased. Also, it has narrow load range so that the switching losses and the efficiency are reduced as it goes to the light load. This paper presents an nove Three-level ZVS PWM DC-DC converter, which can reduce the overvoltage of the outer switches, eliminate the unbalance of the voltage sharing between the switches at turn-off due to the stray inductances, and operate from no load to full load. The characteristics and the performances of the proposed Three-level ZVS PWM DC-DC converter are verified by simulation and experimental results

  • PDF

A Design of PFC Circuit for Reducing the Harmonic in Constant Voltage-fed Electronic Ballast Circuit (정전압형 전자식 안정기 회로의 고조파 저감을 위한 PFC회로의 설계)

  • 이현우;이현무;고강훈;고희석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.41-48
    • /
    • 2004
  • In this paper, a PFC(Power Factor Correction) electronic ballast with constant voltage-fed is proposed. The proposed PFC electronic ballast is combined of a high-efficiency boost converter and a conventional half bridge inverter. It is proved that the ripple of input-current and the input-current's harmonic of the proposed PFC electronic ballast are reduced using the voltage divider and soft-switching technique. It is demonstrated that simulation results for fluorescent lamp correspond with theoretical analysis.

Characteristic Analysis for CCFL drive of LCD backlight (LCD용 백라이트의 CCFL 구동을 위한 특성해석)

  • Ju, Gyeong-Don;Yoon, Shin-Yong;Kim, Cherl-Jin;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.199-202
    • /
    • 2004
  • CCFL(Cold Cathode Fluorescent Lamp) are used to backlight of LCD(Liquid Crystal Display). This paper presents analysis of half-bridge type resonant inverter of CCFL drive in order to stable characteristics, and fluorescent lamp operation frequency is higher than resonant frequency for safe operation. Besides, The Piezoelectric ceramic transformer (PZT) is electro-mechanical device that transfers electrical energy through a mechanical vibration. The modified equivalent circuit model of the PZT considering the operating current level is derived to design the CCFL. The validity of this study was confirmed from the simulation and experiential result.

  • PDF

Power Supply of Ozone Generator using the Single Phase Half-bridge Inverter (단상 하프브리지 인버터를 이용한 오존발생시스템 전원장치)

  • Yoo, Doo-Hee;Park, Jong-Moon;Jeong, Gang-Youl;Moon, Se-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.998-1001
    • /
    • 2009
  • 본 논문은 오존발생시스템의 전원장치에 관한 것으로, 산업화가 가속화 되면서 이에 따른 오염물질을 정화하기 위해 오존($O_3$)의 활용이 점차 증가하고 있으며, 오존발생시스템의 전원장치 또한 많은 연구가 진행되고 있다. 제안된 전원장치는 직류전압으로부터 교류전압을 얻는 가장 간단한 구조인 단상 하프브리지 인버터를 이용한다. 제안한 시스템의 이론적 해석과 동작원리를 보이며, 컴퓨터 시뮬레이션으로 구현하여 이론적 특성과 일치함을 통해 시스템의 성능을 증명한다.

  • PDF