• Title/Summary/Keyword: HCF

Search Result 57, Processing Time 0.031 seconds

A Development of the Automated System for Adjusting the Hexapod Circular Fixator (6자유도 원형체외고정기 조정을 위한 자동화 시스템 개발에 관한 연구)

  • Jung S. G.;Park B. S.;Sim H. J.;Han C. S.;Han J. S.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.505-510
    • /
    • 2004
  • In this article, we present an automated system for adjusting the 6 degree of freedom (D.O.F.) circular fixator. The system includes a scheduling software to adjust the Hexapod Circular Fixator (HCF) and an automated strut with the ability of the multiple synchronized motion and independent motion. The HCF was designed to control a 6 D.O.F. Ilizarov fixator and it's mechanism. The HCF adjustment software evaluates each value of altered length of the HCF struts to correct the complex skeletal deformity by using the X-ray data of the patient. The data of HCF adjustment software feed into the automated strut system which provides the scheduled adjustment. Then, the automated strut is synchronized by input data. Also the data of HCF adjustment software can be used to adjust HCF without automated struts. The proposed HCF system was verified by experiments.

A Study on the Improvement of the Strut for the HCF - Motorized Strut & Digital Gage (HCF용 스트럿의 개선을 위한 연구 - Motorized Strut & Digital Gage)

  • 심형준;한창수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.263-268
    • /
    • 2001
  • Two ways of improvement of the strut for the HCF was made in this paper. The strut for the existing HCF is a passive link, which results the posture of the HCF and related bones. The accuracy of the HCF depends on the accuracy of the strut length. A "digital gage" was proposed to increase the accuracy of the strut by presenting the measuring result as figures in manual mode operation. And a "motorized strut system" was designed for the automated HCF operation. A strut was equipped with a motor, "motorized strut" can be operated manually and automatically. In automatic mode, the HCF operating data is generated by the HCF schedule package in PC and is downloaded to the "motorized strut system" controller. By these two improvements, changes in orthopedic equipments like HCF and other Ilizarov fixators are expected.

  • PDF

A development of the automated system for adjusting the 6 D.O.F circular fixator

  • Jung, Sang-Gil;Park, Bum-Seok;Sim, Hyung-Joon;Jang, Jae-Ho;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1642-1647
    • /
    • 2004
  • In this article, we present the development of the automated system for adjusting the 6 D.O.F circular fixator. The system includes scheduling software to adjust the Hexapod Circular Fixator (HCF) and an automated strut system with the ability of the multiple synchronized motion. HCF was designed to control a 6 degree-of-freedom Ilizarove fixator and it's mechanism is known as the Stewart Platform. HCF scheduler evaluates each value of altered length of the HCF struts to correct the complex skeletal deformity by using the X-ray data of the patient. The data of HCF scheduler feed into the automated strut system which be able to provide the scheduled adjustment and the automated strut is synchronized by input data.

  • PDF

Effects of Electrolyte Concentration on Electrochemical Properties of an Iron Hexacyanoferrate Active Material (헥사시아노 철산철 활물질의 전기화학적 특성에 미치는 전해질 농도의 영향)

  • Yang, Eun-Ji;Lee, Sangyup;Nogales, Paul Maldonado;Jeong, Soon-Ki
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • The effects of electrolyte concentration on the electrochemical properties of Fe4[Fe(CN6)]3(FeHCF) as a novel active material for the electrode of aqueous zinc-ion batteries was investigated. The electrochemical reactions and structural stability of the FeHCF electrode were significantly affected by the electrolyte concentration. In the electrolyte solutions of 1.0-7.0 mol dm-3, the charge-discharge capacities increased with increasing electrolyte concentration, however gradually decreased as the cycle progressed. On the other hand, in the 9.0 mol dm-3 electrolyte solution, the initial capacity was relatively small, however showed good cyclability. Additionally, the FeHCF electrode after five cycles in the former electrolyte solutions, had a change in crystal structure, whereas there was no change in the latter electrolyte solution. This suggests that the performance of the FeHCF electrode is greatly influenced by the hydration structure of zinc ions present in electrolyte solutions.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Preparation and Characterization of Palladium Nanoparticles Supported on Nickel Hexacyanoferrate for Fuel Cell Application

  • Choi, Kwang-Hyun;Shokouhimehr, Mohammadreza;Kang, Yun Sik;Chung, Dong Young;Chung, Young-Hoon;Ahn, Minjeh;Sung, Yung-Eun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1195-1198
    • /
    • 2013
  • Nickel hexacyanoferrate supported palladium nanoparticles (Pd-NiHCF NPs) were synthesized and studied for oxygen reduction reactions in direct methanol fuel cell. The NiHCF support was readily synthesized by a comixing of $Ni(OCOCH_3)_2$ and equimolar $K_3[Fe(CN)_6]$ solution into DI water under rigorous stirring. After the preparation of NiHCF support, Pd NPs were loaded on NiHCF via L-ascorbic acid reduction method at $80^{\circ}C$. Pd-NiHCF NPs were electrochemically active for oxygen reduction reaction in 0.1 M $HClO_4$ solution. X-ray absorption near edge structure analysis was conducted to measure the white line intensity of Pd-NiHCF to verify the OH adsorption. As a comparison, carbon supported Pd NPs exhibited same white line intensity. This study provides a general synthetic approach to easily load Pd NPs on porous coordination polymers such as NiHCF and can provide further light to load Pd based alloy NPs on NiHCF framework.

Operating result of Hydroxyapatite Crystallization-Filtration (HCF) process and characterization of its sludge for wastewater effluent (하수 인 고도처리를 위한 인 결정여과공정 운전결과 및 부산슬러지 특성 검토)

  • Chang, Hyang-Youn;Kim, Weon-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.401-401
    • /
    • 2022
  • 우리나라 대규모 하수처리장에 상용화되어있는 응집공정의 운영상 난점을 극복하고자 대체공정으로 고안된 인 결정여과공정(HCF, Hydroxyapatite Crystallization-Filtration process)의 pilot plant를 구축하고 부산슬러지의 자원화를 위해 그 특성을 검토하였다. 기존의 hydroxyapatite(HAP) 결정화공정 내 탈탄산(decarbonation) 단계를 생략하는 HCF공정의 경우에 고농도의 Ca2+ 주입과 처리수내 탄산염으로 인해 HAP을 포함하는 석회계 슬러지가 발생하는데, 이는 산성화된 토양의 개량제(중화제)로 널리 사용될 수 있다. 본 연구를 위해 경기도 I하수처리장 2차침전지 후단에 구축된 처리용량 27.1 - 135.6 m3/day HCF pilot plant의 전처리 조건은 pH 10.0 - 11.0, Ca2+ 농도 80 mg/L이었다. 결정여과조는 선속도 1.0 - 5.0 m/hr, 상향류로 운전되며, 여재는 2.0 - 3.0 mm의 석회석 모래를 충전하였다. 역세척은 중앙에 Air lifting pipe를 설치하여 역세척수가 처리수와 분리배출되도록 설계하였고, 침전시켜 역세척 슬러지를 회수하였다. 처리수의 평균 T-P, PO4-P 및 SS는 각각 0.05, 0.04, 1.1 mg/L으로 모든 항목에서 방류수 수질기준 이하로 안정적으로 유출되었다. 회수된 HCF 슬러지는 SEM-EDX, XRD, FT-IR을 활용하여 그 특성을 분석하였다. SEM-EDX로 분석된 슬러지의 원자분율은 CaCO3 또는 HAP으로 추측되었다. 또한, XRD spectrum 분석결과, 슬러지의 주요 구성성분은 calcite, HAP, phosphoric acid(H3PO4) 및 brusite로 나타났다. FT-IR 분석결과, 슬러지는 대부분 인산염 및 탄산염의 무기물로 구성되어 있으며, 유입수의 인 농도가 높을수록 슬러지 내 HAP의 함량이 calcite보다 높은 것으로 나타났다. 고농도의 Ca2+을 주입하여 탈탄산단계를 생략한 HCF의 부산슬러지는 HAP 이외에도 CaCO3와 칼슘-인 화합물로 구성되어 있는 것으로 나타났다. 하수 인 고도처리를 위한 HCF공정의 하수처리시설 인 고도처리 적용이 검증되었으며, 부산슬러지를 산성화된 토양의 개량제(중화제) 또는 비료로서의 재활용 및 자원화 가능성이 시사되었다.

  • PDF

Effect of Microstructural Factors on Fatigue and Fatigue Crack Propagation Behaviors of Mill-Annealed Ti-6Al-4V Alloy (미세조직적 인자가 밀소둔된 Ti-6Al-4V 합금의 피로 및 피로균열전파 거동에 미치는 영향)

  • Park, Sanghoo;Kim, Sumin;Lee, Daeun;Ahn, Soojin;Kim, Sangshik
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.12
    • /
    • pp.845-853
    • /
    • 2018
  • To understand the effect of microstructural factors (i.e., the size of ${\alpha}$ phase, equiaxed vs bimodal structure) on high cycle fatigue (HCF) and fatigue crack propagation (FCP) behaviors of mill-annealed Ti-6Al-4V (Ti64) alloy, three specimens of EQ (equiaxed)-8 (8 indicates the size of ${\alpha}$ grain), BM (bimodal)-8, and BM-16 were studied. The uniaxial HCF and FCP tests were conducted at an R ratio of 0.1 under sinusoidal fatigue loading. The microstructural influence (i.e., EQ vs BM) was not significant on the tensile properties of mill-annealed Ti64 alloy, and showed an increase in tensile strength and elongation with decreasing gauge thickness from 50 mm to 1.3 mm. The microstructure, on the other hand, affected the resistance to HCF substantially. It was found that the EQ structure in mill-annealed Ti64 has better resistance to HCF than the BM structure, as a result of different crack initiation mechanism. Unlike HCF behavior, the effect of microstructural features on the FCP behavior of mill-annealed Ti64 was not significant. Among the three specimens, BM-16 specimen showed the highest near-threshold ΔK value, probably because it had the greatest slip reversibility with large ${\alpha}$ grains. The effect of microstructural factors on the HCF and FCP behaviors of mill-annealed Ti64 alloy are discussed based on fractographic and micrographic observations.

Effects of Grain Size on the Fatigue Properties in Cold-Expanded Austenitic HNSs

  • Shin, Jong-Ho;Kim, Young-Deak;Lee, Jong-Wook
    • Metals and materials international
    • /
    • v.24 no.6
    • /
    • pp.1412-1421
    • /
    • 2018
  • Cold-expanded austenitic high nitrogen steel (HNS) was subjected to investigate the effects of grain size on the stress-controlled high cycle fatigue (HCF) as well as the strain-controlled low cycle fatigue (LCF) properties. The austenitic HNSs with two different grain sizes (160 and $292{\mu}m$) were fabricated by the different hot forging strain. The fine-grained (FG) specimen exhibited longer LCF life and higher HCF limit than those of the coarse-grained (CG) specimen. Fatigue crack growth testing showed that crack propagation rate in the FG specimen was the same as that in the CG specimen, implying that crack propagation rate did not affect the discrepancy of LCF life and HCF limit between two cold-expanded HNSs. Therefore, it was estimated that superior LCF and HCF properties in the FG specimen resulted from the retardation of the fatigue crack initiation as compared with the CG specimen. Transmission electron microscopy showed that the effective grain size including twin boundaries are much finer in the FG specimen than that in the CG specimen, which can give favorable contributions to strengthening.

Simulation of the Structural Parameters of Anti-resonant Hollow-core Photonic Crystal Fibers

  • Li, Qing;Feng, Yujun;Sun, Yinhong;Chang, Zhe;Wang, Yanshan;Peng, Wanjing;Ma, Yi;Tang, Chun
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.143-150
    • /
    • 2022
  • Anti-resonant hollow-core photonic crystal fiber (AR-HCF) has unique advantages, such as low nonlinearity and high damage threshold, which make it a promising candidate for high-power laser delivery at distances of tens of meters. However, due to the special structure, optical properties such as mode-field profile and bending loss of hollow-core fibers are different from those of solid-core fibers. These differences have limited the widespread use of AR-HCF in practice. In this paper we conduct numerical analysis of AR-HCFs with different structural parameters, to analyze their influences on an AR-HCF's optical properties. The simulation results show that with a 23-㎛ air-core diameter, the fundamental mode profile of an AR-HCF can well match that of the widely used Nufern's 20/400 fiber, for nearly-single-mode power delivery applications. Moreover, with the ratio of cladding capillary diameter to air-core diameter ranging from 0.6 to 0.7, the AR-HCF shows excellent optical characteristics, including low bending sensitivity while maintaining single-mode transmission at the same time. We believe these results lay the foundation for the application of AR-HCFs in the power delivery of high power fiber laser systems.