• 제목/요약/키워드: H-Bridge Inverter

검색결과 279건 처리시간 0.023초

7-레벨 PWM 인버터의 직렬 커패시터 입력전원의 전압균형제어 (Voltage Balancing Control of Input Voltage Source Employing Series-connected Capacitors in 7-level PWM Inverter)

  • 김진산;강필순
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.209-215
    • /
    • 2018
  • This paper present a 7-level PWM inverter adopting voltage balancing control to series-connected input capacitors. The prior proposed 7-level PWM inverter consists of dc input source, three series-connected capacitors, two bidirectional switch modules, and an H-bridge. This circuit topology is useful to increase the number of output voltage levels, however it fails to generate 7-level in output voltage without consideration for voltage balancing among series-connected capacitors. Capacitor voltage imbalance is caused on the different period between charging and discharging of capacitor. To solve this problem, we uses the amplitude modulation of carrier wave, which is used to produce the center output voltage level. To verify the validity of the proposed control method, we carried out computer-aided simulation and experiments using a prototype.

대전력용 직렬형 멀티레벨 인버터 이용한 STATCOM의 새로운 제어기법 (Novel Control of STATCOM Using Cascade Multilevel Inverter for High Power Application)

  • 민완기;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.136-141
    • /
    • 2000
  • This paper proposes the novel control of a static synchronous compensator (STATCOM). This STATCOM system consists of cascade multilevel inverter which employs H-bridge inverter(HBI) The STATCOM system is modeled in the d-q transform matrix. This model is used to design a controller. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion (THD) low in the output voltage. The switching method produces the staircase type waveform in cascade multilevel inverter. To balance the DC voltages in HBIs capacitor, the rotated switching scheme is newly proposed in this paper. The proposed control scheme is verified in the simulated results.

  • PDF

Full-bridge 고전압 인버터의 출력전압 정밀제어에 관한연구 (Study on the high precision output of full-bride high-voltage inverter)

  • 손윤규;권세진;장성덕;서재학;오종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.214-216
    • /
    • 2005
  • The PAL (Pohang Accelerator Laboratory) is persuading to construct a SASE-XFEL facility (PAL XFEL) that supplies coherent X-rays. The bright and stable electron beam is essential for the PAL XEL. The electron beams has to have an emittance of 1.0 mm-mrad, a peak current of 3 kA, and a low energy spread of 1.0 MeV. In order to provide reasonably stable SASE output, the RF stability of 0.02% rms is required for both RF phase and amplitude. This is a technologically challenging issue for PAL XFEL. An inverter technology is to be applied to charge the PFN of a new modulator. Therefore, a new inverter system should provide very stable charging performances. This paper presents the development of an ultra stable klystron-modulator with an inverter power supply.

  • PDF

직렬형 멀티레벨 인버터를 사용한 대용량 무효전력 보상장치의 파라메타 설계 (Design of Parameters for High Power Static Var Compensator Used Cascade Multilevel Inverter)

  • 민완기;최재호
    • 전기학회논문지P
    • /
    • 제52권4호
    • /
    • pp.172-178
    • /
    • 2003
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). This method has the primary advantage that the number of voltage levels can be increased for a given number of semiconductor devices when compared to the conventional control methods. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. From the mathematical model of the system, the design procedures of the circuit parameters L and C are presented in this thesis. To meet the specific total harmonic distortion(THD) and ripple factor of the capacitor voltage, the circuit parameters L and C are designed. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

Charge Balance Control Methods for a Class of Fundamental Frequency Modulated Asymmetric Cascaded Multilevel Inverters

  • Babaei, Ebrahim
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.811-818
    • /
    • 2011
  • Modulation strategies for multilevel inverters have typically focused on synthesizing a desired set of sinusoidal voltage waveforms using a fixed number of dc voltage sources. This makes the average power drawn from different dc voltage sources unequal and time varying. Therefore, the dc voltage sources are unregulated and require that corrective control action be incorporated. In this paper, first two new selections are proposed for determining the dc voltage sources values for asymmetric cascaded multilevel inverters. Then two modulation strategies are proposed for the dc power balancing of these types of multilevel inverters. Using the charge balance control methods, the power drawn from all of the dc sources are balanced except for the dc source used in the first H-bridge. The proposed control methods are validated by simulation and experimental results on a single-phase 21-level inverter.

DC Rail Side Series Switch and Parallel Capacitor Snubber-Assisted Edge Resonant Soft-Switching PWM DC-DC Converter with High-Frequency Transformer Link

  • Morimoto, Keiki;Fathy, Khairy;Ogiwara, Hiroyuki;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.181-190
    • /
    • 2007
  • This paper presents a novel circuit topology of a DC bus line series switch and parallel snubbing capacitor-assisted soft-switching PWM full-bridge inverter type DC-DC power converter with a high frequency planar transformer link, which is newly developed for high performance arc welding machines in industry. The proposed DC-DC power converter circuit is based upon a voltage source-fed H type full-bridge soft-switching PWM inverter with a high frequency transformer. This DC-DC power converter has a single power semiconductor switching device in series with an input DC low side rail and loss less snubbing capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge arms and DC bus line can achieve ZCS turn-on and ZVS turn-off transition commutation. Consequently, the total switching power losses occurred at turn-off switching transition of these power semiconductor devices; IGBTs can be reduced even in higher switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules can be realized at 60 kHz. It is proved experimentally by power loss analysis that the more the switching frequency increases, the more the proposed DC-DC power converter can achieve a higher control response performance and size miniaturization. The practical and inherent effectiveness of the new DC-DC converter topology proposed here is actually confirmed for low voltage and large current DC-DC power supplies (32V, 300A) for TIG arc welding applications in industry.

25kV 전기철도 고조파 보상을 위한 고전력 능동전력필터 시스템에 관한 연구 (The High Power Active Filter System for Harmonic Compensation of 25kv Electric Railway)

  • 김재철;노성찬;이유경
    • 한국철도학회논문집
    • /
    • 제9권6호
    • /
    • pp.761-765
    • /
    • 2006
  • At present, harmonic currents cause serious problems in power conversion system using the semiconductor switching device. Also some of the conversion system provokes harmonic currents against to the main power supply system and causes hindrances for the system. Main power impedance of the traditional LC passive filter method, influences on the filter characteristics and amplifies the harmonics when resonance phenomenon is occurred. And the traditional existing 2 level inverter systems show the limit in capacity of voltage and current in case of occurring sudden load change. So, to solve this problem active filter which uses cascaded H-bridge multi level inverter has been designed and ex-filter system circuits were totally investigated. With multi level active filtering system not only the size of filter but also the size of filter for transformer can be reduced by half and so as to the weight, while the capacity of inverter can be double sized and wave forms can be compensated exactly and precisely. Also by the benefit of the increase in rating capacity, the various currents owing to the load fluctuation can be dealt more steadily. In order to simulate the wave form of harmonics based on the measured data on the AC 25kV high speed Domestic Commercial railway, it was simulated with PSCAD/EMTDC and PSIM. Based on the results of this demonstration, the power supply system and inverter system would be more stable and also promoting its efficiency.

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

3-레벨 반브리지 인버터로 구성된 새로운 UPFC의 동특성 분석 (Dynamic Characteristic Analysis of Novel Unified Power Flow Controller Using 3-Level Half-Bridge Inverter Modules)

  • 백승택;소용철;한병문
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.116-121
    • /
    • 2004
  • This paper proposes a novel UPFC based on 3-level Half-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC, assuming that the UPFC is connected with the 138-kV transmission line of one-machine-infinite-bus power system. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of 3-level Half-bridge modules.

멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구 (Voltage Dip Compensation Algorithm Using Multi-Level Inverter)

  • 윤홍민;김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.