• 제목/요약/키워드: Grid-Connection

검색결과 307건 처리시간 0.03초

A sensitivity analysis about reactive power according to the interconnection distance of wave-offshore hybrid generation system (복합발전 계통연계 시 보상장치 필요성 분석을 위한 거리에 따른 무효전력 민감성 분석)

  • Jung, Seungmin;Yoo, Yeuntae;Song, Sungyoon;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.251-252
    • /
    • 2015
  • The designed hybrid generation system (HGS) not only consider the voltage condition of grid connection point but also do reactive power support according to the transmission system operator's directions. The PCS operation plan in HGS should be supported by precise transferred quantity expectation about reactive power because the system has large physical areas and also be interconnected with grid through long transmission system. Therefore, the realistic measuring process about transferred reactive power quantity by utilizing HGS is required to consider additional compensation plan. In this paper, an reactive power transferred capability of HGS with expected parameter is analyzed, and imposed to the simulation process that is performed on EMTDC environment. Basically, grid information and system characteristics were utilized with Jeju island in Korea, and the performance analysis is carried out based on the composed layout in ongoing project.

  • PDF

An Algorithm for Electric Vehicle Charging in PV integrated Power System (태양광 발전 연계 계통에서의 전기자동차 충전 알고리즘)

  • Lee, Woong-Hee;Kim, Jun-Hyuk;Lee, Soon-Jeong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.341-342
    • /
    • 2015
  • Attention has been focused on how to charge an electric vehicle in accordance with the increase of interest in the electric vehicle in recent years. The charging of an electric vehicle with a solar power is way to increase the stability of the grid and to supplement the grid power demand. In this paper, the EMTP / ATPDraw presents a method of charging an electric vehicle in connection to the grid and the solar power system, and analyze the trends in supply power from the solar power system according to changes in temperature and irradiation.

  • PDF

The Fundamental Study for Torsional Vibration of Diesel Generator Set connected Electric Power Grids (전력망에 연결된 디젤 발전기 세트의 비틀림 진동에 대한 기초 연구)

  • Kim, Hyujung;Yun, Hyunwoo;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.294-297
    • /
    • 2014
  • A Shipboard power system consists of three or four diesel generator sets connected to a grid. In case of dual fuel diesel generator sets employed LNG ship as a prime mover, large amounts of electricity are required for electric propulsion, auxiliary machinery and accommodation facilities. The electrical connection between generators through a network, torsional vibration can lead power swings. In this paper, the influence on the network by the torsional vibration of diesel generator sets in grid operation were studied. The torsional vibration characteristics were investigated and analyzed through theoretical analysis and the vibration measurement and the results were presented.

  • PDF

PSCAD/EMTDC BASED MODELING AND ANALYSIS OF A GRID-CONNECTED VARIABLE SPEED WIND ENERGY CONVERSION SCHEME (계통연계형 가변속 풍력발전방식의 PSCAD/EMTDC 모의 및 해석)

  • 김슬기;김응상
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제52권8호
    • /
    • pp.413-419
    • /
    • 2003
  • The paper presents a simulation model and analysis of a grid-connected variable speed wind energy conversion scheme (VSWECS) using the PSCAD/EMTDC software. The modeled system uses a variable speed drive, a fixed pitch angle, a synchronous generator as a wind generator and an AC-DC-AC conversion scheme, which facilitates the wind generation to efficiently operate under varying wind speed while connected to the distribution network. The power output of the WECS is controlled by the AC-DC-AC conversion scheme, the objective of which is to capture the maximum active power under varying wind conditions and to keep the voltage magnitude of the terminal bus at a specific level. Aerodynamic models are applied for a wind turbine model. An simulation analysis of the scheme in terms of its responding to wind variations is also presented.

Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage (배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가)

  • Kim, Hyun-Jun;Kim, Do-Hyun;Kim, Kyung-Tae;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제61권1호
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.

A Study on Patterns of Spatial Connection and Visitor's Circulation Path in Museum Exhibition Space (박물관 단위전시실의 공간연결패턴에 따른 관람객 동선특성에 관한 연구)

  • Choi Jun-Hyuck
    • Korean Institute of Interior Design Journal
    • /
    • 제15권3호
    • /
    • pp.155-162
    • /
    • 2006
  • Space is integrated or segment with organic formation by circulation path. It estimates important problem to grasp as factor that promote movement of visitor and space organization without grasping circulation as connection relation about simple space function from these viewpoint, is a thing which this study does not cause confusion to visitor's circulation path through data that analyze form of space connection and visitor's circulation path as quantitative in museum space and layout form that access by easy each unit exhibition grasps what it is. This study does factor grasping for guideline and inspection circulation path of layout by purpose in exhibition space on the basis of analytical result that grasps connection form between exhibition area that grasp laying stress on visitor's movement and appears in space through follow-up survey for circulation path of museum exhibition area. Space connection form that is expose by sequence of investigation and analysis(II) estimates on constituent affecting to visitor's circulation, and these do not speak for all space connection forms at the museum, but may systematize typology about connection form of unit spaces to utilize by indicator pointer of space planning if continue study to various spatial sphere more than hereafter. Unit exhibition area, divide connection form of space by grid and tree and laying stress on this quantitative data by spectator follow-up survey comparison and Estimate that space connection form provides partial basis of judgement for supposition that can promote direction and circulation path about visitor's movement if summarize result of investigation and analysis (III).

Development of Grid Connection Type Inverter for 30kW Wind Power Generation System (30kW급 발전시스템의 계통 연계형 인버터 개발)

  • Hahm, Nyeon-Kun;Kang, Seung-Ook;Kim, Yong-Joo;Han, Kyong-Hee;Ahn, Gyu-Bok;Song, Seung-Ho;Kim, Dong-Yong;Rho, Do-Hwan;Oh, Young-Jin
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.990-992
    • /
    • 2002
  • 30kW electrical power conversion system is delveloped for the variable speed wind turbine system. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and frequency of generator output vary according to the wind speed, a dc/dc boosting chopper is utilized to maintain constant dc link voltage. Grid connection type PWM inverter supply currents into the utility line by regulating the dc link voltage. The active power is controlled by q-axis current which the reactive power can be controlled by d-axis current reference change. The phase angle of utility voltage is detected using s/w PLL(Phased Locked Loop) in d-q synchronous reference frame. This scheme gives a low cost power solution for variable speed WECS.

  • PDF

A Study on the Affordance of Façade design in Domestic Five-star Hotels (국내 5성급 호텔 입면디자인의 시지각적 지원성에 관한 연구)

  • Kim, Su-Hee;Kim, Bong-Ae
    • Korean Institute of Interior Design Journal
    • /
    • 제25권1호
    • /
    • pp.181-191
    • /
    • 2016
  • The purpose of this study is to analyze affordance of façade design by extracting analysis elements of affordance in façade design domestic five-star hotels. The subjects of this study were 88 domestic five-star hotels; we selected literature review and case study as methodology. The analysis elements included mass forms, exterior colors, window frame patterns, exterior characteristics, and door types based on the visual perception factors of façade design from the concept of affordance. The results of the study were as follows. First, the mass forms were divided into stackable, integral, and connection types, and stackable type was most frequent. Second, exterior colors were divided into achromatic, red, yellow, and opaque color parts, and the achromatic parts were most frequent. Third, the window frame patterns were divided into grid, irregular, full, horizontal, and vertical windows, and grid windows were most frequent. Fourth, the exterior characteristics were divided into formative mass, horizontal partition, design contrast, tiled roof, and facility connection, and the formative mass was most frequent. Fifth, the door types were divided into porch, piloti, and wall type, and porch was most frequent. The results of this study showed that the façade design elements such as mass forms, exterior colors, window frame patterns, exterior characteristics, and door types intentionally contained affordance.

Test Results Grid Connection of 120 kW Power Generation System (120 kW급 태양광 발전시스템 설치 및 실 계통연계 운전 결과 평가)

  • Hwang, Jung-Hee;Ahn, Kyo-Sang;Lim, Hee-Cheon;Kim, Su-Chang;Kim, Sin-Sub
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제17권3호
    • /
    • pp.338-346
    • /
    • 2006
  • In this paper, the test results of medium-size(120 kW class) PV system which was installed in the Taeahn thermal power station of Korea Western Power Co., Ltd., were summarized for developing the practical technology to applicate high voltage grid connection PV system. The 120 kW photovoltaic system which was consisted of 1,300 modules, PCS, and 150 kVA transformer station has been operated since Aug. 05, 2005. For verifying the modeling results of PV system, the operation data was compared with modeling results which was executed commercial PSCAD/EMTD and Psim tools. An equivalent circuit model of a solar cell has been also used for solar array modeling. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter(VIS) and its current control scheme have been analyzed by using P&O (perturbation and Observation) MPPT algorithms technique.

Importance Assessment of Multiple Microgrids Network Based on Modified PageRank Algorithm

  • Yeonwoo LEE
    • Korean Journal of Artificial Intelligence
    • /
    • 제11권2호
    • /
    • pp.1-6
    • /
    • 2023
  • This paper presents a comprehensive scheme for assessing the importance of multiple microgrids (MGs) network that includes distributed energy resources (DERs), renewable energy systems (RESs), and energy storage system (ESS) facilities. Due to the uncertainty of severe weather, large-scale cascading failures are inevitable in energy networks. making the assessment of the structural vulnerability of the energy network an attractive research theme. This attention has led to the identification of the importance of measuring energy nodes. In multiple MG networks, the energy nodes are regarded as one MG. This paper presents a modified PageRank algorithm to assess the importance of MGs that include multiple DERs and ESS. With the importance rank order list of the multiple MG networks, the core MG (or node) of power production and consumption can be identified. Identifying such an MG is useful in preventing cascading failures by distributing the concentration on the core node, while increasing the effective link connection of the energy flow and energy trade. This scheme can be applied to identify the most profitable MG in the energy trade market so that the deployment operation of the MG connection can be decided to increase the effectiveness of energy usages. By identifying the important MG nodes in the network, it can help improve the resilience and robustness of the power grid system against large-scale cascading failures and other unexpected events. The proposed algorithm can point out which MG node is important in the MGs power grid network and thus, it could prevent the cascading failure by distributing the important MG node's role to other MG nodes.