• 제목/요약/키워드: Glucose Sensor

검색결과 145건 처리시간 0.026초

마이크로머시닝 기술을 이용하여 제작한 포도당 센서에 관한 연구 (A study on a Glucose Sensor Fabricated by Micromachining)

  • 최석민;노일호;양성준;김창교;유홍진;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.451-454
    • /
    • 2001
  • In this study, a micro-glucose sensor was fabricated by micromachining technology and its sensing characteristics were investigated. The 7740 pyrex glass was used as the bottom substrate and anisotropically etched silicon wafer was used as the top substrate. The size of the fabricated microchip is 1.58${\times}$1.58mm$^2$. It is shown that output current exhibits a linear change according to glucose concentration (100 mM ∼ 300 mM). It is also shown that the response time for glucose was within 240 sec. It was followed by a saturation trend within 50 sec. The g1ucose sensor with Fc$\^$+/ exhibits relatively higher sensitivity than that without Fc$\sub$+/ for output current.

  • PDF

생물공정 모니터링을 위한 Fiber Optic 생물센서 개발

  • 손옥재;이종일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.819-822
    • /
    • 2001
  • In this study a fiber optic biosensor has been developed to on-line monitor the concentrations of oxygen and glucose. The oxygen concentrations in solution and gas phase monitored by the fiber optic sensor has been compared with those by a dissolved oxygen electrode and an IR-type $O_2$ analyzer. The fiber optic glucose sensor has been made by immobilizing glucose oxidase on the tip of the optic fiber and used to on-line monitor the concentration of glucose in a fermentation process.

  • PDF

ISFET 포도당센서를 위한 GOD 고정화막의 사진식각 형성법 (Photolithographic Formation of GOD Immobilized Membranes for ISFET Glucose Sensors)

  • 김창수;최성문;서화일;김의락;손병기
    • 전자공학회논문지A
    • /
    • 제29A권4호
    • /
    • pp.58-63
    • /
    • 1992
  • Photolithography techniques were applied for immobilization of GOD membrane on the pH-ISFET with photo-sensitive polymers to realize ISEFT glucose sensor. This IC technology-compatible glucose sensor showed good sensing characteristics in the wide range of 10-1000 mg/dl glucose concentrations.

  • PDF

ITO 전극 위에 고정된 니켈 나노 입자를 이용한 무효소 혈당센서에 관한 전기화학적인 연구 (The Electrochemical Studies of Non-enzymatic Glucose Sensor on the Nickel Nanoparticle-deposited ITO Electrode)

  • 오인돈;김사만다;최영봉
    • 전기화학회지
    • /
    • 제17권3호
    • /
    • pp.164-171
    • /
    • 2014
  • 무효소 혈당센서는 높은 선택성과 민감성을 가지고 저비용으로 체내 혈당(glucose)을 검출할 수차세대 기술이다. 현재 시판되고 있는 혈당센서는 당을 산화시켜주는 당산화효소와 전극과 효소사이에 전자 전달을 원활하게 해주는 산화/환원 매개체를 이용하여 효소센서로 제작된다. 그러나 이러한 효소센서는 pH, 온도, 습도, 화학적 독성물질 등에 영향을 많이 받아 안정성이 떨어지고, 제작에 비용이 많이 드는 단점을 가지고 있다. 본 논문은 위와 같은 단점을 해결하고자 환원제인 당에 의하여 환원되는 니켈 나노입자를 전기화학적 흡착방법을 이용하여 산화 인듐 주석 전극 (ITO)에 고정시켰다. 고정된 니켈 나노입자는 전극의 표면적을 넓혀 신호를 증폭시키는 효과를 가지고 있으며, 당에 의하여 계속적으로 니켈이 환원됨에 따라 전극 반응에서는 촉매산화전류 반응으로 나타낸다. 당의 농도에 따라서 선형적으로 감응 할 수 있는 최적 조건의 니켈 나노입자를 이용하여 혈당센서를 제작하였다. 또한 체내에 존재하는 방해 인자인 아스코브산의 간섭을 억제하기 위해 음이온 고분자의 표면처리를 통하여 상대적으로 당에 선택적으로 감응하도록 하였다. 제작된 전극을 통하여 당 농도 별 산화 촉매 전류를 순환 전압 전류 법으로 측정한 결과 650 mV (vs. Ag/AgCl)에서 최대 전기적 신호가 발생되었으며, 포도당 0~6.15 mM 의 농도범위에서 전기적 신호가 선형 증가함을 확인할 수 있었다.

Copy Paper as a Platform for Low-cost Sensitive Glucose Sensing

  • Ye Lin Kim;Young-Mog Kim;Junghwan Oh;Joong Ho Shin
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.16-21
    • /
    • 2023
  • This study reports the potential of using commercial copy papers as substrates for simple sensitive glucose detection. Typical paper-based devices use filter papers as porous substrates that can contain reagents; however, this is the first study to report the use of copy papers for the purpose of enhancing enzymatic colorimetric detection. Glucose detection using glucose oxidase, horseradish peroxidase and potassium iodide was performed on a copy paper, cellulose-based filter paper, and polyethylene film. The results indicated that the copy paper exhibited a stronger coloration than the other substrates. Reagents required for detection were dried on the copy paper, and a 3D-printed holder was designed to provide an environment for consistent imaging, making it a convenient cost-effective option for point-of-care testing using a mobile phone camera. The simple paper-based glucose sensor exhibited a linear range of 0.1-20 mM, limit of quantification of 0.477 mM, and limit of detection of 0.143 mM.

Impaction of a continuous glucose monitoring sensor

  • Park, Kyong Chan;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.392-394
    • /
    • 2021
  • A 33-year-old man presented to the plastic surgery department for foreign body removal 1 month after the insertion of a continuous glucose monitoring (CGM) sensor (Dexcom G5) in the left upper arm. The patient had used the CGM system for 5 years, and the insertion was done in the usual manner. The entire sensor wire was visible on simple radiography and ultrasonography. In the operating room, and the sensor wire was identified in the intermuscular septum and removed. No foreign body reaction or inflammatory signs were found around the CGM, and the extracted wire measured 2.5 cm. Thus, it was assumed that the whole sensor wire was detached from the transmitter, not fractured. No remnant foreign body was observed on follow-up simple radiography.

휴대용 뇨당 측정 시스템의 개발 (Development of an Portable Urine Glucose Monitoring System)

  • 박호동;이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.397-403
    • /
    • 2002
  • 뇨당 측정 시스템은 소변 속의 글루코오스 농도를 측정함으로서 당뇨 수치를 모니터링하는 비침습적인 당뇨병 자가 진단 장치이다. 본 논문에서는 기존의 침습형 혈당측정방법의 불편성과 비색계를 이용한 뇨당 검사법의 단점을 보완한 뇨당 측정시스템을 설계하였다. 뇨당 측정시스템은 뇨당 측정용 화학센서, 신호검출부, 디지털 제어 및 신호분석부, 디스플레이부 및 전원부로 구성된다. 뇨당측정용 센서로는 재현성이 뛰어나고 다루기가 간편하며 저렴한 가격으로 대량 생산할 수, 있는 일회용 뇨당측정용 전류화학센서를 개발하였다. 설계한 뇨당 측정시스템의 성능을 평가하기 위하여 사람의 소변에 임의의 농도의 글루코오스 성분을 섞은 용액에 대하여 글루코오스 성분 분석시 사용되는 표준장비와의 비교분석을 통해서 글루코오스 농도 검출에 대한 신뢰성 평가를 수행하였다. 회귀분석에 기초한 신뢰성 평가를 수행한 결과 표준오차는 2.85282로 나타났다. 또한, 화학센서를 사용해서 측정하는 시스템을 평가 시 중요한 파라미터인 S.D(Standard Deviation)는 10%로서 임상적으로 유효한 15% 범주 내에 있음을 확인하였고, C.V(Coefficient of Validation)값은 ,5%이내이므로 혈당센서의 기준으로 평가해 볼때 만족하는 결과를 보였다.

사진식각기술을 이용한 FET형 반도체 요소 및 포도당센서의 제조와 그 특성 (Fabrication and Characteristics of FET Type Semiconductor Urea and Glucose Sensor Employing Photolithography Techniques)

  • 조병욱;김창수;서화일;손병기
    • 센서학회지
    • /
    • 제1권2호
    • /
    • pp.101-106
    • /
    • 1992
  • 반도체 pH 센서인 pH-ISFET와 효소 고정화막을 기술적으로 결합한 FET형 반도체 요소 및 포도당센서를 제조하고 그 동작특성을 조사하였다. 사진식각기술을 이용하여 pH-ISFET의 수소이온 감지막 위에 urease와 glucose oxidase를 감광성 고분자 물질인 PVA(polyvinyl alcohol)-SbQ(stilbazolium group)로 고정화(immobilization)시켰다. 제조된 요소센서와 포도당센서는 각각 $0.5{\sim}50{\;}mg/dl$ 범위의 요소농도와 $10{\sim}1000{\;}mg/dl$의 포도당 농도를 정량 할 수 있었다.

  • PDF

μFIA 바이오 센서를 이용한 포도당 농도 측정 (Measurement of Glucose Concentration Using a μFIA Biosensor)

  • 송대빈
    • Journal of Biosystems Engineering
    • /
    • 제28권5호
    • /
    • pp.465-468
    • /
    • 2003
  • A microdialysis coupled flow injection amperometric biosensor was calibrated to measure the concentration of glucose using 7 standard samples from 10ml to 70ml of glucose solution. The output of the sensor increased linearly with an increase in the glucose concentration with an $R^2$ correlation of 0.99. The amperometric biosensor was then applied to measure the. glucose concentration of 2 commercial samples(Orange and Pineapple juice) and the results compared with HPLC. Around 12% error was observed in glucose concentration measurements of the samples analyzed. The sensor has potential in rapid measurement once the calibration is done. Potential for on-line sensing is also discussed.

ISFET Glucose Sensor with Palladium Hydrogen Selective Membrane

  • Chung, Mi-Kyung;Kim, Seong-Wan;Lee, Sang-Sik;Park, Chong-Ook
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.90-95
    • /
    • 2012
  • This paper describes the development of a glucose biosensor based on ion sensitive field effect transistor(ISFET) with a palladium(Pd) modified ion sensing membrane. By adopting Pd as a hydrogen sensitive layer and integrating a screen-printed reference electrode, the sensitivity and stability were considerably improved due to the high permeability and selectivity of the Pd hydrogen selective membrane. This paper suggests a new approach for realizing portable and highly sensitive glucose sensors for diagnosing and treating diabetes mellitus.