• Title/Summary/Keyword: Geothermal anomaly

Search Result 23, Processing Time 0.026 seconds

Distribution of geothermal resources of Korea (우리나라의 지열자원 분표)

  • Kim, Hyoung-Chan;Lee, Chul-Woo;Song, Yoonho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.674-677
    • /
    • 2005
  • The characteristics of geothermal resources in Korea was roughly estimated using hot springs, 580 geothermal gradients and 338 heat flow data. In the aspect of hot springs with geologic structure, location of hot springs coincide with fault zone, especially younger age of Cretaceous to Tertiary. In the aspect of geothermal gradients, Pohang area shows the highest geothermal gradient anomaly, which is covered with unconsol idated rock of low thermal conductivity preserving the residual heat from igneous activity or radioactivity elements decay. In the aspect of heat flow density, high anomaly can be found along the zone connecting Uljin-Pohang-Busan on the southeastern part of Korean peninsula at which big fault zone as Yangsan fault is well developed.

  • PDF

Development of deep-seated geothermal energy in the Pohang area, Korea (경북 포항지역에서의 심부 지열수자원 개발 사례)

  • Song, Yoonho;Lee, Tae-Jong;Kim, Hyoung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.693-696
    • /
    • 2005
  • KIGAM (Korea Institute of Geoscience and Mineral Resources) launched a new project to develop the low-temperature geothermal water in the area showing high geothermal anomaly, north of Pohang city, for large-scale space heating. Surface geologic and geophysical surveys including Landsat 1M image analysis, gravity, magnetic, Magnetotelluric (MT) and controlled-source audio-frequency MT (CSAMT), and self-potential (SP) methods have been conducted and the possible fracture zone was found that would serve as deeply connected geothermal water conduit. In 2004, two test wells of 1.1km and 1.5km depths have been drilled and various kinds of borehole survey including geophysical logging, pumping test, SP monitoring, core logging and sample analysis have followed. Temperature of geothermal water at the bottom of 1.5km borehole reached over $70^{\circ}C$ and the pumping test showed that the reservoir contained huge amount of geothermal water. Drilling for the production well of 2 km depth is on going. After test utilization and the feasibility study, geothermal water developed from the production well is going to be provided to nearby apartments.

  • PDF

A study on the Effective Utilization of Temperature Logging Data for Calculating Geothermal Gradient (지온경사 산출을 위한 효율적인 온도검층자료 이용방법 연구)

  • 김형찬
    • Economic and Environmental Geology
    • /
    • v.32 no.5
    • /
    • pp.503-517
    • /
    • 1999
  • The purpose of this study is to verfify a more effecive techique for calculating geothermal gradient. this study examines 370 data of temperature-logging having been collected since 1985. The daya are divided into three different grades grades according to the type of temperature-depth plots: 204 data show typical linear gradient (Grade A); 126 data do not explicitily show the gradient becase of various external effects such as water flow (Grade B); and the rest 40 data do not show the gradient at all (Grade D). The new technique for calculating geothermal gradient is to be required to use Greade-B data more effctiviely. This new technique includes (1) calculating the independer depth of atmospheric temperature in the earth; (2) drawing a distribution map of subsurface tempurature by using the distribution map of subsurface temperature by using Grade-A data at the independent depth; and (3) recalculating geothermal gradient of Grade-B data by using the distrbution map of subsurface temperature, borehole depth, and bottom temperature of Grade-B data by using the distribution map of subsurface temperature, borehole depth, and bottom temperature of Grade-B data. As a result, 330 data-both Grade-A and Grade-B data--can be used to draw a distribution map of hot spradient. The map clearly distinguishes anomaly areas, and helps interpret their relations to the distribution of hot springs, geology, geological structures, and geophysical anomaly areas. These new results reveal that the average of geothermal in south Korea is 25.6$^{\circ}C$/km, when calculated to the Kriging method.

  • PDF

Characterization on the Geological Structures and Geothermal Gradient Distribution in the Yusong Area (유성온천지역의 지질구조 및 지온분포 연구)

  • 정지곤;서만철;김경수;황형중
    • The Journal of Engineering Geology
    • /
    • v.7 no.3
    • /
    • pp.173-189
    • /
    • 1997
  • A study on the geological structure and geothermal gradient distribution was carried out to evaluate the feasibility of developing a new geothermal field in the Yusong area. It is suggested that geothermal water in the Yusong area is closely related with faults, dykes, and their dipping characteristics with the study of geothermal gradient distribution. A fault of EW direction locates in northern boundary of the study area and another fault of N40{\citc}W$ crosses the EW fault at the western part of the study area. Locations of faults are recognized quite well by lineaments, geophysical exploration and geothermal gradient distribution characteristics. Three sets of dyke are found in the study area. According to the result of the geothermal gradient distribution study, the location of geothermal anomaly belt and dykes coincide each other, and the area has the temperature gradient of larger than 3$^{\circ}C$ between the depths of 0.5m and 1.0m below ground surface. The thermal anomaly belt those temperature gradient is larger than 2.5$^{\circ}C$ between the depths of 0.5m and 1.Om below ground surface is expected in the direction of N80{\citc}W$ in the study area. The dirping of dyke is almost vertical according to the linear distribution of dykes on surface and the results of geophysical survey. From the distribution of geothermal anomaly belt and the locations of dyke, three locations for the development of hot spring water could be recommended and the depth that ensure over 4$0^{\circ}C$ geotheraral water is estimated as 170~200m below the ground surface.

  • PDF

Geothermal properties for Database (지열자료 정보 D/B 구축 요소)

  • Kim, Hyoung-Chan;Park, Jeong-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.28-31
    • /
    • 2006
  • It is require to construct geothermal database to develop geothermal energy as renewable energy policy. It must be consist of geologic data, borehole data and geophysical data for geothermal database. In aspect of geology, there are included the distribution of geology, structural geology, geological time, rock name, density of rock, porosity, thermal diffusivity, specific capacity and thermal conductivity In order to calculate the heat general ion, it is needed to analysis the radioactivity elements as U, Th and K of rock. In aspect of borehole data, there are included temperature of depth, surface temperature and geothermal gradient And also there is geotherrnornetry using chemical components of groundwater as Na Ca, K and $SiO_2$. In aspect of geophysical data, there are some thematic map as booger gravity anomaly data and magnetic survey data and etc. In addition, it is important to descript the distribution of hot spring and water temperature.

  • PDF

Modeling of SP responses for geothermal-fluid flow within EGS reservoir (EGS 지열 저류층 유체 유동에 의한 SP 반응 모델링)

  • Song, Seo Young;Kim, Bitnarae;Nam, Myung Jin;Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.4
    • /
    • pp.223-231
    • /
    • 2015
  • Self-potential (SP) is sensitive to groundwater flow and there are many causes to generate SP. Among many mechanisms of SP, pore-fluid flow in porous media can generate potential without any external current source, which is referred to as electrokinetic potential or streaming potential. When calculating SP responses on the surface due to geothermal fluid within an engineered geothermal system (EGS) reservoir, SP anomaly is usually considered to be generated by fluid injection or production within the reservoir. However, SP anomaly can also result from geothermal water fluid within EGS reservoirs experiencing temperature changes between injection and production wells. For more precise simulation of SP responses, we developed an algorithm being able to take account of SP anomalies produced by not only water injection and production but also the fluid of geothermal water, based on three-dimensional finite-element-method employing tetrahedron elements; the developed algorithm can simulate electrical potential responses by both point source and volume source. After verifying the developed algorithm, we assumed a simple geothermal reservoir model and analyzed SP responses caused by geothermal water injection and production. We are going to further analyze SP responses for geothermal water in the presence of water production and injection, considering temperature distribution and geothermal water flow in the following research.

A two-dimensional inversion of MT and AMT data from mid-mountain area of Jeiu island (제주도 중산간 지역 MT 및 AMT 탐사자료의 2차원 역산)

  • Lee, Tae-Jong;Song, Yoon-ho;Uchida,Toshihiro;Park, In-Wha;Lim, Sung-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.21-26
    • /
    • 2005
  • Two-dimensional (2-D) inversion of magnetotelluric (MT) data for two survey lines having south-north direction from Jeiu Island has been carried out. The 2-D models show a thick layer having around 10 ohm-m in the depth of a few hundred meters throughout the survey area, which can be considered as the unconsolidated sedimentary layer. And they also show a conductive anomaly at the central part of each survey lines. But unfortunately by now, we do not have any further information about the anomaly. Comparison of the 2-D inversion model using MT band only and that using both AMT and MT bands said that it is helpful for us to include AMT band as well as MT band in the inversion to interpret not only the shallow part but also the deep structures.

  • PDF

포항 지열 개발지역에서의 지열 저류층에 대한 SP 모델링

  • ;;;Kasumi Yasukawa
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.417-421
    • /
    • 2004
  • Self-potential (SP) survey was carried out at Pohang geothermal field. SP measurement showed clear positive anomaly at northern part of the test wells, which can be a up-flow zone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. To give a clearer image of the fluid flow pattern around the test wells, a two-dimensional numerical simulation was applied to construct a numerical block model of the fluid flow system based on SP and magnetotelluric survey results. The result suggests existence of two high permeability zones including the main manifestation area in the northern part of the test wells.

  • PDF

Magnetotelluric surveys from mid-mountain area of Jeju Island for evaluating possible structures for deep-seated geothermal energy (심부 지열에너지 개발 가능성 파악을 위한 제주도 증산간 지역에서의 MT 탐사)

  • Lee, Tae-Jong;Lee, Seong-Kon;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.434-437
    • /
    • 2006
  • Though numerous drilling has been performed in Jeju Island for development of ground water, the wells are mostly located along the coast lines or at low altitude area, and can hardly be found on the mid-mountain area. Two-dimensional magnetotelluric (MT) surveys have been carried out to cover the lack of geological Informal ion on the mid-mountain area and to figure out any possible structures or evidences for deep geothermal energy remained. Two-dimensional (2-D) inversion of MT data for four survey lines surrounding the Halla mountain show a thick layer having around 10 ohm-m in the depth of a few hundred meters throughout the survey area, which can be considered as the unconsol idated sedimentary layer. And they also show a conductive anomaly extending to more than 2km depth at the central part of each survey lines, which can possibly be related with old volcanic activities during the formation of Halla Mt.. Further seological/geophysical investigations should be followed.

  • PDF

Electromagnetic Tomography Using Finite Element Method (유한요소법을 이용한 전자탐사 토모그래피 연구)

  • Son, Jeong-Sul;Song, Yoon-Ho;Kim, Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.185-190
    • /
    • 2007
  • In this study, we developed the 2.5D EM modeling and inversion algorithm for cross-hole source and receiver geometry. Considering the cross-hole environment, we use a VMD (vertical magnetic dipole) as a source and vertical magnetic fields as a measuring data. Developed inversion algorithm is tested for the isolated block model which has a conductive and a resistivity anomaly respectively. For the conductive anomaly, its size and resistivity are inverted well on the inversion results, while for the resistive anomaly, the location of anomalous block is shown on the inverted section, but its values are far from the exact value. Furthermore, artificial conductive anomalies are shown around the resistive anomalous zone. If we consider the inversion artifact shown in the test inversion of restive block, it is almost impossible to image the resistive zone. However, the main target of EM tomography in the engineering problem is conductive target such as fault zone, and contaminated zone etc., EM tomography algorithm can be used for detecting the anomalous zone.

  • PDF