• Title/Summary/Keyword: Geometric Distance

Search Result 399, Processing Time 0.024 seconds

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

Intersection Sight Distance Based on Critical Gap at Unsignalized Intersections (임계간격을 이용한 비신호 교차로의 시거 산정에 관한 연구)

  • 이슬기;이용재;김석근
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.5
    • /
    • pp.97-110
    • /
    • 2003
  • The sight distance at unsignalized intersections is the one of the fundamental geometric design elements, and can ensure safety and efficient operations. Despite its importance, little research attention has been directed in Korea compared to developed countries such as European countries, the United States, and Japan. AASHTO ISD policies have been applied to the intersection design in Korea without any revise, which can produce unrealistic and unadoptable design values. Those values are emerged from several reasons because the AASHTO ISD has been calibrated based on the local data. Therefore the ISD hardly takes into account the local characteristics of Korea such as driving behavior. vehicular movement and roadway conditions. The objective of this study is to calculate the appropriate ISD values for unsignalized intersections in the urban area in Korea. In this study, we employed the ISD model of AASHTO(2001), which is based on gap acceptance theory and can account for and take the driving and roadway conditions in Korea into consideration. The approach can also consider the complex driving maneuvers at the intersections in a proper and simple manner. The results in this study show that the ISD design criteria currently used in Korea are more conservative(safer) than those of the USA. In other words, the ISD using field data collected in this study has generally smaller values than those in USA.

Verification of Spatial Resolution in DMC Imagery using Bar Target (Bar 타겟을 이용한 DMC 영상의 공간해상력 검증)

  • Lee, Tae Yun;Lee, Jae One;Yun, Bu Yeol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.5
    • /
    • pp.485-492
    • /
    • 2012
  • Today, a digital airborne imaging sensor plays an important role in construction of the numerous National Spatial Data Infrastructure. However, an appropriate quality assesment procedure for the acquired digital images should be preceded to make them useful data with high precision and reliability. A lot of studies therefore have been conducted in attempt to assess quality of digital images at home and abroad. In this regard, many test fields have been already established and operated to calibrate digital photogrammetric airborne imaging systems in Europe and America. These test fields contain not only GCPs(Ground Control Points) to test geometric performance of a digital camera but also various types of targets to evaluate its spatial and radiometric resolution. The purpose of this paper is to present a method to verify the spatial resolution of the Intergraph DMC digital camera and its results based on an experimental field testing. In field test, a simple bar target to be easily identified in image is used to check the spatial resolution. Images, theoretically designed to 12cm GSD(Ground Sample Distance), were used to calculate the actual resolution for all sub-images and virtual images in flight direction as well as in cross flight direction. The results showed that the actual image resolution was about 0.6cm worse than theoretically expected resolution. In addition, the greatest difference of 1.5cm between them was found in the image of block edge.

Determination of Not-Permitted Entrance/Exit Section at Curb Areas (단지 내 진출입 불허구간의 적정길이 산정에 관한 연구)

  • Kwon, Sung-Dae;Park, Je-Jin;Ha, Tae-Jun;Ha, Dong-Ik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4D
    • /
    • pp.369-376
    • /
    • 2010
  • At present, many problems in traffic operation and safety occurs since there is no clear design criteria on designating the not-permitted entrance/exit section at curb areas within complex areas. Even, there is no specific and detailed researches on the not-permitted entrance/exit section by now. This research calculated the proper length of the entrance/exit section at curb areas by dividing the access not-permitted section into the two sections. First, the calculation of the entrance section was done by considering the location of crosswalks, stop line clearance, the queue length of vehicles approaching to second lanes, and marginal distance for safety have been considered. Second, the calculation of the exit section was done by comparing and analyzing the distance between cars of the entrance section according to the investigation point and the distance considering the location of crosswalks, the behavior of exit vehicles and the length of vehicles. In conclusion, by presenting the proper length in consideration of the traffic operation and safety on the access not-permitted section within complex areas, it can be used as a traffic safety improvement alternative and will be contributed in establishing and operating the proper installation criteria for the access not-permitted section within complex areas.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Marker Detection by Using Affine-SIFT Matching Points for Marker Occlusion of Augmented Reality (증강현실에서 가려진 마커를 위한 Affine-SIFT 정합 점들을 이용한 마커 검출 기법)

  • Kim, Yong-Min;Park, Chan-Woo;Park, Ki-Tae;Moon, Young-Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.55-65
    • /
    • 2011
  • In this paper, a novel method of marker detection robust against marker occlusion in augmented reality is proposed. the proposed method consists of four steps. In the first step, in order to effectively detect an occluded marker, we first utilize the Affine-SIFT (ASIFT, Affine-Scale Invariant Features Transform) for detecting matching points between an enrolled marker and an input images with an occluded marker. In the second step, we apply the Principal Component Analysis (PCA) for eliminating outlier of the matching points in the enrolled marker. And then matching points are projected to the first and second axis for longest value and the shortest value of an ellipse are determined by average distance between the projected points and a center of the points. In the third step, Convex-hull vertices including matching points are considered as polygon vertices for estimating a geometric affine transformation. In the final step, by estimating the geometric affine transformation of the points, a marker robust against a marker occlusion is detected. Experimental results have shown that the proposed method effectively detects occlude markers.

Size Distributions of Amphiboles in Soils from a Closed Asbestos Mine, Jecheon, Chungcheongbuk-do, Korea (충청북도 제천시 폐석면광산 주변 토양에서 검출되는 각섬석의 크기 분포)

  • Kwon, Jiwoon;Choi, Sung Won;Kim, Hyunwook
    • Economic and Environmental Geology
    • /
    • v.47 no.5
    • /
    • pp.497-505
    • /
    • 2014
  • This study is for discrimination between asbestiform and non-asbestiform based on size characteristics of tremolite-actinolite fibers in soils from a closed asbestos mine, Jecheon, Chungcheongbuk-do, Korea. Soils and tremolite asbestos rocks were collected from a closed asbestos mine area. The dimensions of fibers with minimum $5{\mu}m$ in length and 3:1 in aspect ratio were measured using transmission electron microscopy (TEM) and compared to the known tremolite populations ranging from asbestiform to non-asbestiform. The geometric means of width of soils, asbestos rocks and National Institute for Standard and Technology (NIST) and Health and Safety Laboratory (HSL) reference samples were $1.2{\mu}m$, $0.3-0.6{\mu}m$, $1.3{\mu}m$ and $0.2{\mu}m$, respectively. The geometric means of aspect ratio of soils, asbestos rocks and NIST and HSL reference samples were 7.3, 13.7-30.1, 7.2 and 37.8, respectively. The population of tremolite-actinolite fibers from soils compared to known asbestiform and non-asbestiform tremolite was lack of thin and high aspect ratio fibers. Upper results suggest that tremolite-actinolite fibers in soils cannot be classified into a commercial grade asbestos. The tremolite-actinolite fibers do not mainly appear to be the result of contamination from distance asbestos sources by wind. For the management and control of asbestos in soils, size distributions of amphiboles should be incorporated into asbestos survey results of soils.

The Improvement Effect of MMSC (DL-Methionine Methylsulfonium Chloride) in Functional Dyspepsia Animal Models (동물모델을 이용한 MMSC(DL-Methionine Methylsulfonium Chloride)의 기능성소화불량증 개선효과)

  • Kim, Jae Min;Cha, Myoung Hee;Lee, Don Haeng;Lee, Woon Kyu
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.2076-2081
    • /
    • 2013
  • The objective of this study is to investigate the gastric emptying and gastrointestinal transit improvement effect of DL-methionine methylsulfonium chloride (MMSC) in functional dyspepsia animal models. Cisplatin causes nausea, vomiting, and inhibition of gastric emptying. Rats were divided into four groups: G1 (normal group), G2 (gastric emptying induced by cisplatin), G3 (gastric emptying induced by cisplatin with itopride 30 mg/kg pretreatment), and G4 (gastric emptying induced by cisplatin with MMSC 4 mg/kg pretreatment). Immediately after an oral administration of a liquid meal (phenol red), delayed gastric emptying was induced by cisplatin (10 mg/kg (i.p.)). After 20 min in the cisplatin administration, the animals were sacrificed. In rats treated with cisplatin, the gastric emptying rate was significantly reduced. On the other hand, MMSC reversed the reduction of gastric emptying induced by cisplatin. And also, MMSC caused to travel FITC-dextran more significantly longer distance than the control, which is based on the values of the mean geometric center in the atropine driven delayed gastrointestinal transit animal models. Furthermore, MMSC drastically increased the gastrointestinal transit in rats, considerably increased the values of the mean geometric center (MGC), compared to the control, which was comparable to that of mosapride. These results suggest that MMSC could be an effective component for the treatment of functional dyspepsia.

Exposure Assessment of Extremely Low Frequency Magnetic Fields by variable exposure matrices for the Selected Primary Schoolchildren Living Nearby and Away from a Overhead Transmission Power Line (다양한 노출 매트릭스를 통한 송전선로 주변과 비 주변 거주 초등학교 학생의 극저주파 자기장 노출량 평가에 관한 연구)

  • Kim, Yoon Shin;Hyun, Youn Joo;Choi, Seong Ho;Lee, Chul Min;Roh, Young Man;Cho, Yong Sung;Hong, Seung Cheol
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.334-345
    • /
    • 2006
  • The objectives of this study were to analyze and compare 24 hrs personal exposure levels of MF at microenvironments such as home, school, educational institute, internet pc game room, transportation, and other places according to time activity patterns using various metrics for children attending the primary schools located near and away from the power lines, and to characterize the major microenvironments and impact factors attributed personal exposure level. The study was carried out for 44 children attending a primary school away from the lines(school A) and 125 children attending a school away from 154 kV power lines(school B), all who aged 12 years and were 6 grade, from July 2003 to December 2003. All participants filled in a questionnaire about characteristics, residence, use of electrical appliances and others. Children wore a small satchel in which EMDEX II and Lite (Enertech, Co. Ltd) and a diary of activity list for period of registration in 20 minutes blocks. All statistical calculations were made with the SAS System, Releas 6.12. The summary of results was presented below. First, about the characteristics of subjects, there no differences between two groups. The subject almost spent about 56 % of their time at home and about 20~25 % of their time at school. Fifty percent of children spent 2 hours at private educational institutes. Second, the personal exposure measurements of children in school B was statistically higher than those of children in school A by various metrics such as arithmetic mean, geometric mean, percentile(5, 25, 50, 75, 95), maximum, rate of change metric, constant field metric. The arithmetic and geometric mean magnetic fields during the time the children were at school B were 0.98 and $0.86{\mu}T$ and were about 23 times higher than those of children were at school A. In conclusion, the significant major determinants of personal exposure level is the distance from the power line to microenvironments.

3D Finite Element Analysis of High Tension Bolted Joints (고장력 볼트 이음부의 3차원 유한요소 해석)

  • Shim, Jae Soo;Kim, Chun Ho;Kim, Dong Jo
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.407-414
    • /
    • 2004
  • Bridges in common use are expected to have more varieties of load in their connected members and bolts than in construction. Faults in connection members or bolts occur so often according to the time flow. One of the purposes of this study is to find out the behavior and structural features of high-tension bolted joints with faults that are very difficult and cost much to find out through experimentation with finite element analysis. Another purpose of this study is to provide sufficient data, estimated experimental results, and the scheme of the test plate for an economical experimental study in the future. Surveys of bridges with a variety of faults and statistical classifications of their faults were performed, as was a finite element analysis of the internal stress and the sliding behavior of standard and defective bridge models. The finite element analysis of the internal stress was performed according to the interval of the bolt, the thickness of the plate, the distance of the edge, the diameter of the bolt, and the expansion of the construction. Furthermore, the analysis explained the sliding behavior of high-tension bolt joints and showed the geometric non-linear against the large deformation, and the boundary non-linear against the non-linear in the contact surface, including the material non-linear, to best explain the exceeding of the yield stress by sliding. A normally bolted high-tension bolt joint and deduction of bolt tension were also analyzed with the finite element analysis of bridge-sliding behavior.