• Title/Summary/Keyword: Gauge length

Search Result 170, Processing Time 0.212 seconds

Evaluation of the true-strength characteristics for isotropic materials using ring tensile test

  • Frolov, A.S.;Fedotov, I.V.;Gurovich, B.A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2323-2333
    • /
    • 2021
  • The paper proposes a technique for reconstructing the true hardening curve of isotropic materials from ring tensile tests. Neutron irradiated 42XNM alloy tensile properties were investigated. The calculation of the true hardening curve for tensile and compression tests of standard cylindrical samples was performed at the first step. After that, the FEM-model was developed and validated using the ring tension and compression tests (with the hardening curve defined in step 1). Finally, the true hardening curve was calculated by selecting the FEM-model parameters and its validation by ring sample tests in different states using an iterative method. For these samples, experimental and calculated gauge length values were obtained, and the corresponding material's constants were estimated.

Fatigue Evaluation of a Steel Bridge in Service through Stress History Measurement and Consideration of Stress Category (공용중인 교량의 응력이력 계측 및 응력범주를 고려한 피로평가)

  • Na, Sung-Ok;Kwon, Min-Ho;Cha, Cheol-Jun;Kim, In-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.108-116
    • /
    • 2014
  • The proper stress history measurement should be conducted in order to examine the accurate cause of fatigue cracks or the fatigue safety in the steel bridge. Only one strain gauge is generally installed in the field for the stress history examination because of the field circumstances, economic feasibility, workability, and so on. However, this method may not consider the actual size of the specific structure, the gauge length, and the affect of stress concentration in the welded joint. In addition, it is difficult to apply for the stress analysis. Therefore, this study suggests improvements that are a great number of gauge installations, the gauge location adjustment, and the use of the minimum length gauge. It is drived the correlative equation of strain for the distance between the welding toe and the strain gauge installation, and compare correlative equation with equation of IIW. Also, this study could estimate the remaining life and fatigue damage of bridge in service by selecting the suitable stress category. In conclusion, it is possible to understand the member which is high in the fatigue cracks, and the quantitative relations between the welding toe and the strain gauge installation distances. The proposed approach in this study can make an more accurate fatigue damage and a remaining life prediction so that the improved method should be applied in measuring the strain of bridges from now on.

Intervention Analysis of Urbanization Effect on Rainfall Data at the Seoul Rain Gauge Station (서울지점 강우자료에 나타난 도시화의 간섭 분석)

  • Yoo, Chul-Sang;Kim, Dae-Ha;Park, Sang-Hyoung;Kim, Byung-Su;Park, Chang-Yeol
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.8
    • /
    • pp.629-641
    • /
    • 2007
  • This study estimated the urbanization effect of Seoul, the largest city in Korea, on its rainfall. For a comparative analysis, two different data sets are used: One is the precipitation data at the Jeonju rain gauge station, which has a relatively long record length but least urbanization effect, and the other at the Ichon rain gauge station, which has a short record length but located very near to Seoul with least urbanization effect. Also, the difference of the rainfall between Seoul and Jeonju rain gauge stations, as an indicator of urbanization effect, is quantified by use of the intervention model. As a result, it was found that the maximum rainfall intensity of the annual maximum rainfall events shows the increasing trend, its duration the decreasing trend, and the mean intensity the decreasing trend especially after 1960. Also, the quantification of urbanization effect using the intervention model shows that the increasing trend of rainfall intensity and total volume is still on going.

Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel (CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성)

  • Jeong, Ill-Seok;Ha, Gak-Hyun;Kim, Tae-Ryong;Jeon, Hyun-Ik;Kim, Yeong-Sin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.17-22
    • /
    • 2007
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor. The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside the small autoclave. So the magnet type LVDT's were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. FEM calculated the displacement and the strain of the gauge length from the data measured at the shoulders. Tensile test properties in elastic and plastic behavior of CF8M material were used in the FEM analysis. A series of low cycle fatigue tests simulating the cyclic strain hardening effect verified that the FEM calculation was well agreed with the simulated tests. The process and method developed in this study would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.

  • PDF

Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel (CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성)

  • Jeong, Il-Seok;Ha, Gak-Hyun;Kim, Tae-Ryong;Jeon, Hyun-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.2
    • /
    • pp.177-185
    • /
    • 2008
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor (PWR). The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside a small autoclave. So the magnet type LVDT#s were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. Displacement of the fatigue specimen gauge length calculated by FEM (finite element method) used to modify the measured displacement and fatigue life at the shoulders. A series of low cycle fatigue life tests in air and PWR conditions simulating the cyclic strain hardening effect verified that the FEM modified fatigue life was well agreed with the simulating test results. The process and method developed in this study for the environmental fatigue test inside the small sized autoclave would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.

A SPEECH-PHONETIC STUDY ON THE PRONUNCIATION OF THE OPENBITE PATIENTS (개교환자의 발성에 관한 언어 음성학적 연구)

  • Kim, Ki-Dal;Yang, Won Sik
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.287-307
    • /
    • 1991
  • This study aimed at examining speech defects of openbite patients, which were analized in terms of formant frequency for vowels and word pronunciation length for consonants. In addition, the upper and lower lip (perioral m.) activity was tested by the EMG. The tongue force was measured by the strain gauge, and the speech discrimination test was carried out. One experimental group and one control group were used for this study and they were respectively composed of six female openbite patients and six normal-occlusion females. Eight monophthongs, two fricatives and two affricatives were chosen for speech analysis. Speeches of the above-mentioned groups were recorded and then analized by the ILS/PC-1 software. Four hundred most frequently used monosyllables were also chosen for discrimination score. Openbite patients showed the following characteristics: 1. Abnormality in case of /a/, $/\varepsilon/$, /e/, /i/ $F_2$ and /e/, /a/ $F_1$. 2. Significantly elongated length in their pronunciation of /h/ and $/C^h/$ and somewhat elongated length also in their pronunciation of /s/ and /c/. 3. Significant upper lip activity according to the EMG test during pronunciation of the bilabial consonants. 4. Relatively weak tongue force according to the strain gauge measurement. 5. According to the speech discrimination test, high rate of misarticulation in case of (a) initial /p/ /s'/ and /ts'/, (b) /a/,$/\varepsilon/$,/e/,/je/,/o/, $/\phi/$,/jo/,/u/,/we/, and /i/ (c) final (equation omitted).

  • PDF

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

Laser Interferometer and Length Standards (레이저간섭계와 미터표준)

  • 엄태봉;서호성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.17-24
    • /
    • 2000
  • 1960년 Jawan 등이 1.15㎛ 파장을 포함한 6개의 발진파장을 갖는 He-Ne 레이저의 연속 발진을 성공시킨 이후 레이저는 단색성이나 빛의 진직성을 이용하는 계측에서 특히 정밀길이측정에서 매우 중요하게 사용되고 있다. He-Ne 레이저의 발진선폭은 80㎑로써 길이표준기로 사용되었던 Kr-86 스펙트럼선의 선폭(400㎒)의 5,000 분의 1에 해당되는 매우 좁은 선폭을 갖고 있다.(중략)

  • PDF