• 제목/요약/키워드: Gate-Cycle

검색결과 155건 처리시간 0.026초

Intelligent Power Module의 플로팅 게이트 전원 공급을 위한 전하 펌프 회로의 설계 (Design of Charge Pump Circuit for Intelligent Power Module of Floating Gate Power Supply)

  • 임정규;김석환;서은경;정세교
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.421-423
    • /
    • 2005
  • A bootstrap circuit for floating power supply has the advantage of being simple and inexpensive. However, the duty cycle and on-time are limited by the requirement to refresh the charge in the bootstrap capacitor. Hence, this paper deals with a design of charge pump circuit for a floating gate power supply of an IPM. The operation of the proposed circuit applied by three-phase inverter system for driving induction motor are verified through the experiments.

  • PDF

LCA기법을 이용한 천연펄프의 환경 영향 평가 (Environmental Impact Evaluation of Virgin Pulp Using Life Cycle Assessment Methodology)

  • 김형진;조병묵;황용우;박광호
    • 펄프종이기술
    • /
    • 제36권1호
    • /
    • pp.49-60
    • /
    • 2004
  • Life Cycle Assessment for the pulp, which is mainly used as the raw material of fine paper, base paper for food packaging and paper cup, has been carried out in this study to consider environmental aspects by quantifying the environmental emission and to evaluate its environmental impact potential. The system boundary was selected from cradle to gate stage(raw material acquisition, transportation of raw material and product manufacturing) of the product. Environmental impact was divided into 8 categories considering Korean situation: abiotic resource depletion, global warming, ozone depletion, acidification, eutrophication, photochemical oxidant creation, ecotoxicity and human toxicity. In Life Cycle Impact Assessment(LCIA) methodology phase, Ecopoint, Eco-indicator 95 and Korean eco-indicator were used and the results carried out by each methodology were compared. The results from this study were also compared with those of foreign study to verify the reliability of the results. The results of the study could be utilized as the basic data for Environmental Management System(EMS), Design for Environment(DfE) and Type III eco-labeling in the paper and paper-related industry.

H.264 High-Profile Intra Prediction 모듈 설계 (A design of High-Profile Intra Prediction module for H.264)

  • 서기범;이혜윤;이용주;김호의
    • 한국정보통신학회논문지
    • /
    • 제12권11호
    • /
    • pp.2045-2049
    • /
    • 2008
  • 본 논문에서는 AMBA 기반으로 사용될 수 있는 H.264용 High Profile Intra Prediction을 구조를 제안한다. 설계된 모듈은 한 매크로 블록 당 최대 306 cycle내에 동작한다. 제안된 Encoder 구조를 검증하기 위하여 JM 13.2로부터 reference C를 개발하였으며, reference C로부터 test vector를 추출하여 설계된 회로를 검증하였다. 우리는 Hardware cost를 줄이기 위하여 plan mode를 제거 하였고, SAD 계산 방법과 8 pixel 병렬처리 등을 사용하여 Hardware cost와 cycle을 줄이는 방법을 채택하였다. 제안된 회로는 Full HD1080@fps 영상을 133MHz clock에서 동작시킬 수 있으며, 합성결과 TSMC 0.18um 공정에 램 포함 25만gate크기 이다.

금강 하구역에서 영양염류, 엽록소, 부유물질과 염분변화에 대한 500일간의 연속관측 (500-days Continuous Observation of Nutrients, Chlorophyll Suspended Solid and Salinity in the Keum Estuary, Korea)

  • 이용혁;양재상
    • 한국해양학회지:바다
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 1997
  • 군산 하구역에서 해양학적 환경의 시간적 변화양상을 이해하고 하구언 축조 이후 갑문의 조작에 의한 환경의 변화를 알아보기 위하여 1995년 6월부터 1996년 9월까지 약 500일간 매일 관측을 하였다. 조사대상 항목은 해양환경의 일반적인 조사대상인 영양염, 엽록소, 부유현탁물질 그리고 염분이었으며, 이들 자료를 설명하기 위하여 일차적으로 조석자료를 이용하였고, 또한 보조자료로서 기온, 강우량, 풍속등 기상 자료와 금강 하구언의 담수 방출량과 같은 하구언의 갑문조작 효과도 그 관련성을 조사하였다. 조석 위상에 따른 변화를 조사하기 위하여 1996년 4월에 26시간, 7월에 19시간에 걸쳐 시간별로 연속조사를 병행하였다. 시간별 조사에서 염분의 변화양상은 조위에 비례관계를 보였으며, 부유현탁물질과 엽록소는 창 낙조 사이에서 높은 농도를 보였다. 영양염류는 염분에 반비례하는 경향을 보였다. 500일 연속 관측에서 염분은 당수 방출량과 반비례하며, 엽록소는 봄철에 높은 농도를 보였다. 각 영양염류는 변화양상이 유사하였고, 염분과는 반비례 관계를 나타내었다. 부유현탁물질은 15일 주기인 조석 주기(neap-spring tide cycle)와 유사한 양상을 보였으며, 홍수기에는 담수 방출량에 의하여 주로 결정되었다. 금강 하구언의 갑문을 조작하기 이전과 비교해 볼 때 담수의 방출은 우기에 집중되고 있으며, 조류의 감소, 부유물질의 감소, 영양염류와 엽록소의 증가를 보였다.

  • PDF

조류(藻類)제어를 위한 실용적 신기술 : K-water 녹조수상콤바인 (A Practical New Technology of Removing Algal Bloom: K-water GATe Water Combine)

  • 신재기;김호준;김세원;정선아;문병천;이상협;최재우
    • 생태와환경
    • /
    • 제47권3호
    • /
    • pp.214-218
    • /
    • 2014
  • 본 연구노트는 K-water가 고안하여 개발한 녹조수상 콤바인 장치에 대하여 소개하고자 하였다. 녹조제거장치는 본체와 부력재, 이송호퍼, 스크린 컨베이어, 슬러지 제거기 및 수거물질 분리대 등 총 5개 모듈로 구성되어 있다. 그리고 스컴성 녹조현상 이하일 때 녹조제거제를 전처리할 수 있는 살포기가 별도로 장착되어 있다. 전반적으로 본 장치의 모듈 시스템은 매우 간단하다. 2014년 5월부터 7월까지 낙동강 및 대청호 현장에서 테스트 운영한 결과, 1일 처리할 수 있는 수표면적은 $500,000m^2day^{-1}$에 해당하였다. 그리고 장치 적용 전후 처리효율은 90%를 상회하였고, 수처리량은 수질 상태에 따라 차이가 있지만 $500,000m^3day^{-1}$은 가능하였다. 또한 장치의 운영기간은 3월~11월(9개월) 동안으로써 기존 계획보다 연장될 수 있었다. 본 장치 및 기술을 통해 상수원과 공공수역의 녹조현상 및 사회문제로 확대된 파급 영향을 해결하는 데 기여할 수 있는 신기술로서 활용되기를 기대한다.

Selective Latch Technique을 이용한 고속의 Dual-Modulus Prescaler (A High-Speed Dual-Modulus Prescaler Using Selective Latch Technique)

  • 김세엽;이순섭김수원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.779-782
    • /
    • 1998
  • This paper describes a high-speed Dual-modulus Prescaler (DMP) for RF mobile communication systems with pulse remover using selective latch technique. This circuit achieves high speed and low power consumption by reducing full speed flip-flops and using a selective latch. The proposed DMP consists of only one full speed flip-flop, a selective latch, conventional flip-flops, and a control gate. In order to ensure the timing of control signal, duty cycle problem and propagation delay must be considered. The failling edgetriggered flip-flops alleviate the duty cycle problem andthis paper shows that the propagation delay of control signal doesn't matter. The maximum operating frequency of the proposed DMP with 0.6um CMOS technology is up to 2.2㎓ at 3.3V power supply and the circuit consumes 5.24mA.

  • PDF

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.

확산모형에 의한 하구에서의 오염물질이동 예측(수공) (Prediction of Pollutant Transport by Dispersion Model on Estuary)

  • 박영욱;박상현;천만복;이봉훈;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.371-377
    • /
    • 2000
  • Environmental impact on a land reclamation project, Hwaong tidal barrier was studied using the dispersion and advection model to predict the influence of polluted water discharged from freshwater reservior. The simulation results show that the distribution of concentration by influence of polluted water discharged during a tidal cycle appeared to be extinguished at atmost all points after two tidal cycle. Peak concentration near the sluice gate is found out to be higher during the spring tide than neap tide. Equi-concentration contour line appeared to distributed a longer according to line of sea dike in spring tide than neap tide. The reasons is because influence by currents of northwest direction is a stronger, compared to spring tide and neap tide in the flood tide.

  • PDF

Performance Analysis of Gas Turbine for Large-Scale IGCC Power Plant

  • Joo, Yong-Jin;Kim, Mi-Yeong;Park, Se-Ik;Seo, Dong-Kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.415-419
    • /
    • 2016
  • As the need for clean coal technology has grown, so has the global research and development efforts into integrated gasification combined cycle (IGCC) plants. An IGCC plant couples a gas turbine to a gasification block. Various technical and economic problems exist in designing such a system. One such problem is the difficulty in realizing economies of scale because the single-train flow capacity of commercial IGCC synthetic gas turbine plants is limited; the capacity does not exceed a net power rating of 300 MW. To address this problem, this study modeled and simulated a synthetic gas turbine with the goal of evaluating the feasibility of a 500 MW or larger IGCC plant. First, a gas turbine with the best output and efficiency was chosen for use with natural gas. The turbine was modeled using GateCycle (a simulation tool), and the integrity of the model validated by comparing the result to the design value. Next, off-design modeling was carried out for a gas turbine with synthetic gas based on its on-design model, and the result was compared with the study result of the gas turbine manufacturer. The simulation confirmed that it is possible to create a large capacity IGCC plant by undertaking the remodeling of a gas turbine designed to use natural gas into one suitable for synthetic gas.

A Systems Engineering Approach to Real-Time Data Communication Network for the APR1400

  • Ibrahim, Ahmad Salah;Jung, Jae-cheon
    • 시스템엔지니어링학술지
    • /
    • 제13권2호
    • /
    • pp.9-17
    • /
    • 2017
  • Concept development of a real-time Field Programmable Gate Array (FPGA)-based switched Ethernet data communication network for the Man-Machine Interface System (MMIS) is presented in this paper. The proposed design discussed in this research is based on the systems engineering (SE) approach. The design methodology is effectively developed by defining the concept development stage of the life-cycle model consisting of three successive phases, which are developed and discussed: needs analysis; concept exploration; and concept definition. This life-cycle model is used to develop an FPGA-based time-triggered Ethernet (TTE) switched data communication network for the non-safety division of MMIS system to provide real-time data transfer from the safety control systems to the non-safety division of MMIS and between the non-safety systems including control, monitoring, and information display systems. The original IEEE standard 802.3 Ethernet networks were not typically designed or implemented for providing real-time data transmission, however implementing a network that provides both real-time and on-demand data transmission is achievable using the real-time Ethernet technology. To develop the design effectively, context diagrams are implied. Conformance to the stakeholders needs, system requirements, and relevant codes and standards together with utilizing the TTE technology are used to analyze, synthesize, and develop the MMIS non-safety data communication network of the APR1400 nuclear power plant.