• 제목/요약/키워드: Gas target

검색결과 846건 처리시간 0.029초

건설회사의 온실가스·에너지 목표관리제 대응전략 분석에 관한 연구 (A Study on Counter Strategy of GHG·Energy Target Management System for Construction Firm)

  • 노승준;태성호;김태형
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.135-136
    • /
    • 2012
  • The purpose of this study is to analysis of counter strategy of greenhouse gas·energy target management system for the construction firm. For this purpose, the greenhouse gas·energy target management system of other industries was investigated. The selection possibility that is construction firm to be managed company was analyzed. In addition, status of counter strategy on the greenhouse gas·energy target management system were investigated and analyzed about 5 domestic major construction firm via questionnaire and interview. As a result, the counter strategy by organization and annual for the greenhouse gas·energy target management system was drawn.

  • PDF

가연성가스 수송배관에 대한 목표 신뢰도 수준 설정에 관한 연구 (A Study on Establishing Target Reliability Levels for Flammable Gas Transmission Pipelines)

  • 이진한;조영도;문종삼
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.52-58
    • /
    • 2018
  • 신뢰도 기반 접근법(RBDA)에서, 신뢰도 목표는 설계 및 유지관리 단계에서 관계되는 한계상태를 충족할 수 있는 정도의 안전 수준을 가지는 지 확인하기 위해서 사용된다. 우리나라의 경우 가연성 가스 배관에 대한 신뢰도 목표는 아직 개발되거나 활용되지 못하고 있다. 다만 신뢰도 목표 대신에 사회적 위험과 개인적 위험과 같은 위험 측정지표에 대한 허용가능(tolerable) 판단기준이 배관의 위험관리에 적용되어 왔다. 본 논문에서는 고압천연가스 배관에 대한 정량적 위험평가 시 판단기준으로 삼는 사회적, 개인적 위험 판단기준을 사용하여 신뢰도 기반 접근법의 핵심요소인 목표 신뢰도를 개발하는 절차를 소개하고 자 한다. 또한 소개된 절차를 통해 천연가스와 수소가스 수송배관에 대한 신뢰도 목표를 제안한다.

마이크로 가스센서의 열적 성능에 관한 연구 (A Study of Thermal Performances for Micro Gas Sensor)

  • 주영철;김창교
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.531-537
    • /
    • 2006
  • A lever type $NO_2$ micro gas sensor was fabricated by MEMS technology. In order to heat up the gas sensing material to a target temperature, a micro heater was built on the gas sensor. The sensing material laid on the heater and electrodes and did not contact with the silicon base to minimize the heat loss to the silicon base. The electric power to heat up the gas sensor to a target temperature was measured. The temperature distribution of micro gas sensor was analyzed by a CFD program. The predicted electric power of micro heater to heat up the sensing material to the target temperature showed a good agreement with the measured data. The design of micro gas sensor could be modified to show more uniform temperature distribution and to consume less electric power by optimizing the layout of micro heater and electrodes.

DEVELOPMENT OF A METHOD FOR CONTROLLING GAS CONCENTRATION FOR USE IN C.A EXPERIMENTS

  • Yun, H.S.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.662-669
    • /
    • 2000
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and low cost system was developed for controlling gas concentration for use in C.A experiments. The gas flow rate through capillary tube had a linear relationship with pressure, $(length)^{-1}$ and $(radius)^4$ of capillary tube, which agreed well with Hagen-Poiseuille's law. The developed system could control the gas concentration in storage chamber within ${\pm}0.3%$ deviation compared to the preset concentration. The required time for producing target gas concentration in storage chamber was exactly predicted by the model used in this study, and it required much longer time than the calculated time which divided the volume of chamber by flow rate. Therefore, for producing target gas concentration as quickly as possible, it needs to supply higher flow rate of gas during the initial stage of experiment when gas concentration in storage chamber has not reached at target value. It appeared that the developed system was very useful for C.A experiments. Because one could decide a desired flow rate by the prediction model, control flow rate freely and easily by changing pressure in the pressure-regulating chamber and the accuracy was high.

  • PDF

국내 천연가스배관 유지관리를 위한 목표신뢰도 적용사례 (Application of Target Reliability Levels for Maintenance of Domestic Natural Gas Pipelines)

  • 이진한;김정환;조영도;김래현
    • 한국가스학회지
    • /
    • 제22권3호
    • /
    • pp.1-6
    • /
    • 2018
  • 신뢰도기반 설계 및 평가(RBDA) 방법론은 천연가스 배관을 설계하는 최신의 방법 중 하나이다. 신뢰도 목표는 설계와 유지관리 단계에 걸쳐 관계된 한계상태을 충족하는 안전수준을 가지는 지 확인하기 위해 사용된다. 목표 신뢰도는 대누출과 파단과 같은 극한한계상태에 대한 개인적 위험과 사회적 위험에서 사용하는 허용 가능한 위험수준을 적용하여 개발되었다. 본 논문에서 신뢰도 목표는 배관의 생애주기 동안 주기적인 유지관리를 적용함으로써 충족할 수 있음을 보여준다. 사례분석은 국내 천연가스 수송배관에 대한 굴착공사에 따른 손상확률 계산, 부식에 따른 손상확률의 계산, 그리고 재검사 주기의 추정을 포함한다.

FEM을 이용한 C-11 기체표적의 성능평가 (Application of C-11 Gas Target Using Finite Element Method)

  • 허민구;오환섭;정효진;박상필;양승대
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1699-1704
    • /
    • 2005
  • In this research the energy degrader, which is the most fragile part of the security of a target, has been newly designed to improve the performance of the gas target. Also, the numerical analysis of the heat movement and mechanical movement during the operation of the target has been accomplished. The heat analysis and structure analysis which are using the cooling water flow and pressure in the energy degrader and the Nastran mediocrity finite element analysis program, has been considered with the heat movement and mechanical movement according to the current capacity of proton beam which determines the production yield of the radioactive isotope. Also the possible use range has been determined, and at the same time the most suitable running condition according to the current capacity of proton beam has been suggested.

  • PDF

on-axis 스퍼터링 방법에 의한 $YBa_2Cu_3O_{7-y}$ 초전도 박막 제조 (Preparation of $YBa_2Cu_3O_{7-y}$ Superconducting Thin Films by on-axis Sputtering)

  • 한재원;박정래;최무용
    • 한국진공학회지
    • /
    • 제4권2호
    • /
    • pp.172-176
    • /
    • 1995
  • $YBa_2Cu_3O_{7-y}$ thin films have been prepared on MgO(100)substrates placed on-axis to the target by dc magnetron sputtering in a variety of oxygen/argon gas pressures with different substrate-target distances. We found that films with the c-axis perpendicular to the substrate deposited in an optimally high gas pressure with on-axis substrate-target configuration do. Increasing the substrate-target distance was found to be effetive in reducing the resputtering effect and enhancing superconductivity of films, but not so much $\alpha$-and c-axis growth of YMCO films on MgO substrates. Dependences of the Tc, the rationj of resistances at 300K and 100K, and the X-ray diffraction pattern on the gas pressure and the substrate target distance are described.

  • PDF

FEM을 이용한 C-11 동위원소 기체표적의 성능평가 (The Evaluation of Performance of C-11 Radio Isotope Gas Target using Finite Element Method)

  • 오환섭;허민구;박상필;정효진
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.24-31
    • /
    • 2006
  • The energy degrader is the most fragile part of the security of a target, has been newly designed to improve the performance of the gas target. Also, the numerical analysis of the heat movement and mechanical movement during the operation of the target has been accomplished. The heat analysis and structure analysis which are using the cooling water flow and pressure in the energy degrader and the finite element analysis program, has been considered with the heat movement and mechanical movement according to the current capacity of proton beam which determines the production yield of the radioactive isotope. Also the possible use range has been determined and at the same time the most suitable running condition according to the current capacity of proton beam has been suggested.

전력수급기본계획의 불확실성과 CO2 배출 목표를 고려한 발전용 천연가스 장기전망과 대책 (Scenario Analysis of Natural Gas Demand for Electricity Generation in Korea)

  • 박종배;노재형
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1503-1510
    • /
    • 2014
  • This study organizes scenarios on the power supply plans and electricity load forecasts considering their uncertainties and estimates natural gas quantity for electricity generation, total electricity supply cost and air pollutant emission of each scenario. Also the analysis is performed to check the properness of government's natural gas demand forecast and the possibility of achieving the government's CO2 emission target with the current plan and other scenarios. In result, no scenario satisfies the government's CO2 emission target and the natural gas demand could be doubled to the government's forecast. As under-forecast of natural gas demand has caused the increased natural gas procurement cost, it is required to consider uncertainties of power plant construction plan and electricity demand forecast in forecasting the natural gas demand. In addition, it is found that CO2 emission target could be achieved by enlarging natural gas use and demand-side management without big increase of total costs.

Analysis of Potential Reductions of Greenhouse Gas Emissions on the College Campus through the Energy Saving Action Programs

  • Woo, Jeongho;Choi, Kyoung-Sik
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.191-197
    • /
    • 2013
  • Republic of Korea announced the reduction target to be around 30% of business as usual greenhouse gas emissions by 2020. College campuses were ranked at the 5th of high energy consumption areas in the building sectors. Target management scheme was designed to set greenhouse gas emissions target including several college campuses. Previous studies showed the amount of greenhouse gas emissions with several assumptions such as the applications of renewable energy systems and light emitting diode lamps, etc. Long-range Energy Alternatives Planning model was utilized to simulate future greenhouse gas emissions. This study sets standard model labs for energy saving action programs by applying guidance studies. It has been deduced that energy saving action programs was responsible for reducing 949.5 kWh for each standard model lab and the total reduction of all 59 model labs in the Engineering College building has been calculated to 56,020.5 kWh. The objective of the study is to provide guidelines on standard model laboratory for greenhouse gas emissions reduction on the campus.