• 제목/요약/키워드: Gas detector

검색결과 574건 처리시간 0.026초

현장실험을 통한 축산시설로부터 배출되는 축산악취의 확산 평가 (Evaluation of Odor Dispersion from Livestock Building through Field Experiment)

  • 여욱현;이인복;하태환;데카노 크리스티나;김락우;이상연;김준규;최영배;박유미
    • 한국농공학회논문집
    • /
    • 제61권6호
    • /
    • pp.21-30
    • /
    • 2019
  • Livestock odor is comprised of mixed type of odorous compounds. Among these, ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) are the two known major odor causing substances. Because high odor concentration reduces productivity of livestock and causes damage to the surrounding communities, quantitative analysis is needed to manage the odor inside and outside the livestock facilities. It is also necessary to evaluate odor dispersion according to the distance between the receptors taking into account the influence of odor source and weather condition. Therefore, in this study, we tried to evaluate the internal environment and odor dispersion from experimental pig house considering weather conditions. An experimental farm was specifically selected to eliminate the interference of odors generated by adjacent farms. $NH_3$ and complex odor were quantitatively analyzed using a gas detector and air dilution sensory method. The concentration of $NH_3$ and complex odor in pig house showed a distinct concentration difference according to the cleaning and ventilation conditions. $NH_3$ concentration and complex odor was lower than emission standard in the pig house and at the site boundary. The average $NH_3$ concentration (P1~P3) and the $NH_3$ concentration at the site boundary (S1) were strongly correlated with R=0.77. While the correlation for complex odor inside and at the site boundary had R=0.52. The correlation coefficient between $NH_3$ and the complex odor was 0.80.

HPLC Determination of Tolperisone in Human Plasma

  • Bae Jung-Woo;Park Young-Seo;Sohn Uy-Dong;Myung Chang-Sun;Ryu Byung-Kwon;Jang Choon-Gon;Lee Seok-Yong
    • Archives of Pharmacal Research
    • /
    • 제29권4호
    • /
    • pp.339-342
    • /
    • 2006
  • A simple high performance liquid chromatographic (HPLC) method was developed for the determination of tolperisone in human plasma. Tolperisone and internal standard (chlorphenesin) were isolated from 1 mL of plasma using 8 mL of dichlormethane. The organic phase was collected and evaporated under nitrogen gas. The residue was then reconstituted with 300 mL aliquot of mobile phase and a 100 mL aliquot was injected onto the $C_{18}$ reverse-phased column. The mobile phase, $45\%$ methanol containing $1\%$ glacial acetic acid and $0.05\%$ 1-hexanesulfonic acid was run at a flow rate of 1 mL/min. The column effluent was monitored using UV detector at 260 nm. The retention times for tolperisone and the internal standard were approximately 7.1 and 8.4 min, respectively. The standard curve was linear with minimal intra-day and inter-day variability. The quantification limit of tolperisone in human plasma was 10 ng/ mL. The proposed method has been applied to the determination of pharmacokinetic profile of tolperisone in Koreans. The T max of tolperisone in Koreans $(0.94{\pm}0.42\;h)$ was not significantly differ from that reported in Europeans (0.5-1 h), but the mean half-life in Koreans $(1.14{\pm}0.27\;h)$ was shorter than that in Europeans $(2.56{\pm}0.2\;h)$. The proposed HPLC method is simple, accurate, reproducible and suitable for pharmacokinetic study of tolperisone.

Components of phytoncide from a pine forest in the southern temperate zone

  • Lee, Jeong Do;Park, Choong Hee;Joung, Da Wou;Koo, Seung Mo;Park, Bum Jin
    • 농업과학연구
    • /
    • 제46권1호
    • /
    • pp.33-44
    • /
    • 2019
  • This study was conducted to examine the components of phytoncide from a pine forest in the southern temperate zone. Recent studies have found that a large amount of phytoncide is released not only from cypress trees but also from pine trees. Because the amount released is the highest during summer, we selected a warm climate region in the southern temperate zone and measured the concentration in the month of August. To capture the phytoncide from the forest atmosphere, we used the adsorption tube method with a mini pump and successfully gathered 9 L of forest air at a flow rate of 150 mL/min. We performed duplicate sampling from two different tubes installed at the same location and derived the mean value. A gas chromatography/mass spectrometer detector with thermal desorption spectroscopy was utilized to perform quantitative and qualitative analyses of the captured material. The results showed that the average phytoncide particle of the pine forest in the southern temperate zone contained a number of components as follows in descending order: ${\alpha}$-Pinene (39%, $0.28ng/m^3$), followed by ${\beta}$-Pinene (16%, $0.11ng/m^3$), D-Limonene (8%, $0.06ng/m^3$), camphor (6%, $0.04ng/m^3$), camphene (6%, $0.04ng/m^3$), and p-Cymene (5%, $0.04ng/m^3$). There were also 13 additional phytoncide components in trace amounts. The results of this study are expected to provide a useful dataset for building a "Healing-forest".

Chemical Composition of Cactus Pear Seed Oil: phenolics identification and antioxidant activity

  • Ali, Berraaouan;Abderrahim, Ziyyat;Hassane, Mekhfi;Marianne, Sindic;Marie-Laure, Fauconnier;Abdelkhaleq, Legssyer;Mohammed, Aziz;Mohamed, Bnouham
    • 대한약침학회지
    • /
    • 제25권2호
    • /
    • pp.121-129
    • /
    • 2022
  • Objectives: The chemical composition of cactus pear seed oil (Opuntia ficus-indica [L.] Mill.) was analyzed in terms of its fatty acid composition, tocopherol content, phenolic identification, and the oil's phenolic-rich fraction antioxidant power was determined. Methods: Fatty acid profiling was performed by gas chromatography coupled to an FI detector. Tocopherols and phenolic compounds were analyzed by LC-FLD/UV, and the oil's phenolic-rich fraction antioxidant power was determined by phosphomolybdenum, DPPH assay and β-carotene bleaching test. Results: Fatty acid composition was marked by a high unsaturation level (83.22 ± 0.34%). The predominant fatty acid was linoleic acid (66.79 ± 0.78%), followed by oleic acid (15.16 ± 0.42%) and palmitic acid (12.70 ± 0.03%). The main tocopherol was γ-tocopherol (172.59 ± 7.59 mg/kg. In addition, Tyrosol, vanillic acid, vanillin, ferulic acid, pinoresinol, and cinnamic acid were identified as phenolic compounds in the analyzed seed oil. Moreover, the oil's phenolics-rich fraction showed a significant total antioxidant activity, scavenged DPPH up to 97.85%, and effectively protected β-carotene against bleaching (97.56%). Conclusion: The results support the potential use of cactus pear seed oil as a functional food.

A DFT Study on the Polarizability of Di-substituted Arene (o-, m-, p-) Molecules used as Supercharging Reagents during Electrospray Ionization Mass Spectrometry

  • Abaye, Daniel A.;Aniagyei, Albert;Adedia, David;Nielsen, Birthe V.;Opoku, Francis
    • Mass Spectrometry Letters
    • /
    • 제13권3호
    • /
    • pp.49-57
    • /
    • 2022
  • During electrospray ionization mass spectrometry (ESI-MS) analysis of proteins, the addition of supercharging agents allows for adjusting the maximal charge state, affecting the charge state distribution, and increases the number of ions reaching the detector thus, improving signal detection. We postulate that in di-substituted arene isomers, molecules with higher polarizability values should generate greater interactions and hence elicit higher signal intensities. Polarizability is an electronic parameter which has been demonstrated to predict many chemical interactions. Many properties can be predicted based on charge polarization. Molecular polarizability is a vital descriptor for explaining intermolecular interactions. We employed DFT (density functional/Hartree-Fock hybrid model, B3LYP)-derived descriptors and computed molecular polarizability for ten disubstituted arene reagents, each set made up of three (ortho, meta, para) isomers, with reported use as supercharging reagents during ESI experiments. The atomic electronic inputs were ionization potential (IP), electron affinity (EA), electronegativity (𝛘), hardness (η), chemical potential (µ), and dipole moment (D). We determined that the para isomers showed the highest polarizability values in nine of the ten sets. There was no difference between the ortho and meta isomers. Polarizability also increased with increasing complexity of the substituents on the benzene ring. Polarizability correlated positively with IP, EA, 𝛘, η, and D but correlated negatively with chemical potential. This DFT study predicts that the para isomers of di-substituted arene isomers should elicit the strongest ESI responses. An experimental comparison of the three isomers, especially of larger supercharging molecules, could be carried out to establish this premise.

HF-LPME를 이용한 수용액 시료중의 카페인 분석 (Analysis of caffeine in aqueous sample by hollow fiber-liquid microextraction (HF-LPME))

  • 인치연;김택제;명승운
    • 분석과학
    • /
    • 제21권2호
    • /
    • pp.84-92
    • /
    • 2008
  • 속빈 섬유-액상 미량추출법(hollow fiber-liquid phase microextraction, HF-LPME)과 기체 크로마토그래프/질소-인 검출기(GC-NPD)를 사용하여 사람의 뇨와 여러 가지 음료 중에서 극미량의 카페인을 분석하는 방법을 확립하였다. 수용액 시료로부터 카페인의 양을 측정하기 위해서 속빈 섬유의 길이, 추출용매의 종류, 교반효과, pH 및 염석효과 등 여러 가지 실험적인 파라미터를 변화시켜서 최적의 조건을 확립하고자 하였다. 검정곡선의 회귀계수($r^2$)는 0.9994이상이었으며, 평균 상대 회수율은 102%(n=3)이었으며, 기기검출한계는 2.5 ng/mL, 정량한계는 10 ng/mL이었다. 확립된 HF-LPME 방법은 생물학적 시료, 음식물, 환경시료 중에서 카페인의 농도를 측정하기에 편리하고 정확한 방법이 될 것이다.

대전, 충천 지역 제빵류의 조지방 및 트랜스 지방산 함량 조사 (Analysis of Trans Fatty Acid and Crude Fat Contents of Bakery Foods in Chung-cheong Province)

  • 김유미;허옥순;이기택
    • 동아시아식생활학회지
    • /
    • 제17권4호
    • /
    • pp.540-546
    • /
    • 2007
  • 대전, 충청(청주, 천안)지역의 제과점에서 수거한 제빵류 42개의 시료에서 조지방을 추출하고 이것을 Gas Chromatography(GC)를 이용하여 트랜스 지방의 함량을 분석하였다. 수거한 시료는 생크림 케이크 9개, 페이스츄리 9개, 슈크림 7개, 크로켓 9개, 찹쌀 도넛 8개였다. 추출한 시료의 조지방 함량은 페이스츄리 10.67$\sim$34.26%로 가장 높은 조지방 함량을 보였으며, 찹쌀 도넛은 1.44$\sim$4.34%로 가장 낮은 조지방 함량을 보였다. 트랜스 지방의 함량은 생크림 케이크 0.03$\sim$1.31 g/100 g of food, 페이스츄리가 0.21$\sim$2.69 g/100 g of food, 슈크림 0.09$\sim$0.43 g/100 g of food, 크로켓 0.22$\sim$1.99g/100 g of food, 찹쌀 도넛 0.02$\sim$0.38 g/100 g of food로 페이스츄리가 시료들 중에서 가장 높은 함량을 나타내었으며, 분석한 시료들 중에서 트랜스지방의 함량이 2 g/100g of food를 초과하는 시료가 모두 페이스츄리에서 검출되었다.

  • PDF

GC-ECD 및 GC-MS를 이용한 현미 중 chloropicrin의 잔류시험법 개발 (Development of an Analytical Method for Chloropicrin Determination in Hulled Rice by GC-ECD and GC-MS)

  • 도정아;최정희;박혜진;박용춘;윤혜정;최동미;오재호
    • 한국식품위생안전성학회지
    • /
    • 제28권3호
    • /
    • pp.222-226
    • /
    • 2013
  • Chloropicrin은 국내에서는 사용되지 않으며, 잔류허용기준이 불검출로 설정된 농약이다. 그러나 중국에서는 훈증제, 살균제, 살선충제 및 저장 곡물의 살충제로 사용되고 있으며, 잔류허용기준이 설정되어 있다. 따라서 본 연구에서는 중국 등에서 수입하는 식품 중 국내에서 사용하지 않는 농약에 대한 안전성을 확보하기 위하여 해당 농약을 신속하고 빠르게 검출할 수 있는 시험법을 개발하고자 하였다. Chloropicrin은 분자량이 작고 휘발성이 큰 화합물이므로 헤드스페이스 추출법을 활용하여 검체 추출액을 직접 GC에 주입하는 시험법을 개발하였으며, 확립된 시험법을 검증한 결과 회수율이 77.7~79.3%로 조사되어 코덱스 국제가이드라인(CAC/GL 40)에 적합함을 확인하였다. 정량한계 또한 0.05 mg/kg 이하로 매우 우수한 감도를 가지고 있음을 확인하였으며, GC-MS를 이용한 재확인과정을 추가로 확립하여 본 시험법의 신뢰도를 높였다. 확립된 시험법은 식품에 잔류할 수 있는 농약의 기준 준수여부에 대한 적합성을 판단하기 위한 공정시험법으로 활용되고 있다.

9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구 (A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank)

  • 김청균
    • 한국가스학회지
    • /
    • 제14권5호
    • /
    • pp.13-18
    • /
    • 2010
  • 본 연구는 9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템을 개발하고자 한다. 새로운 통합제어안전관리 시스템은 기존의 측정 및 제어시스템에 비해 압력, 변위, 하중을 측정할 수 있는 장치를 추가하였다. 또한, 측정된 데이터는 새로운 제어장치와 안전관리 시스템에 의해 통합되고 분석하는 프로세스를 동시적으로 진행하는 것이다. 초대형 완전밀폐식 LNG 저장탱크의 안전성과 효율성을 증가시키기 위해 통합제어안전관리시스템은 압력계이지를 추가하고, 내부탱크의 외측벽과 스티프너, 톱거더의 용접지역, 코너 프로텍션 탱크의 외측벽에 새로운 변위센서/압력센서를 설치하였다. 변위센서와 하중센서는 내부탱크와 코너 프로텍션 탱크의 9% 니켈강재 구조물에 대한 파손징후를 제공할 수 있고, 내부탱크로부터 누설되는 LNG를 감시할 수 있다. 기존의 누설센서는 내부탱크와 코너 프로텍션 사이의 단열지역에 설치한 누설감지기에 의해 경고신호가 접수될 때까지도 9% 니켈강재 탱크의 파괴에 대한 적절한 정보를 제공하지 못한다는데 문제가 있다. 따라서, 새로운 통합제어안전관리시스템은 온도, 압력, 변위, 하중, LNG의 밀도 데이터를 수집하고 분석하기 위한 것으로, 탱크시스템의 안전성과 내부탱크의 누설을 제어하기 위한 시스템이다. 또한, 디지털 데이터는 9% 니켈강재로 제작한 탱크의 안전성에 관련된 변위와 하중, LNG의 액위와 밀도, 쿨다운 공정, 누설, 압력 등을 제어하기 위해 측정한다.

멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구 (A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank)

  • 김청균
    • 한국가스학회지
    • /
    • 제14권2호
    • /
    • pp.40-46
    • /
    • 2010
  • 본 연구에서는 기존 멤브레인식 LNG 저장탱크의 측정장치와 안전장치에 대한 고찰과 분석을 통해 초대형 멤브레인 식 LNG 저장탱크에 적합한 새로운 통합제어안전관리시스템 연구를 수행하고자 한다. 통합제어안전관리시스템은 기존에 단수로 설치한 압력계를 추가하고, 기존의 LNG 저장탱크에는 없는 변위센서와 하중센서를 내부탱크와 예응력 콘크리트 구조물 사이를 관통하는 강재앵커에 새로이 설치함으로써 초대형 LNG 저장탱크의 안전성과 효율성을 향상시키는 역할을 담당할 것으로 예상된다. 변위센서와 하중센서는 멤브레인 패널의 파손여부, 내부탱크로부터 발생된 LNG 누설의 단서를 제공하게 될 것이다. 기존의 누설센서는 내부탱크 뒤편의 보냉재 공간에 설치한 온도센서에 의해 LNG 누설이라는 신호를 보낼 때까지도 멤브레인 패널의 손상에 관련된 적절한 정보를 제공하지 못할 수 있다. 결국 새로운 통합제어안전관리시스템은 온도, 압력, 변위량, 하중, LNG의 밀도 데이터를 수집하고 분석하기 위한 것으로, 탱크시스템의 안전성과 내부탱크의 누설을 제어하기 위한 시스템이다. 또한, 디지털 데이터는 멤브레인 패널의 안전성에 관련된 변위량과 하중, LNG의 액위와 밀도, 쿨다운 공정, 누설, 압력 등을 제어하기 위해 측정된다.