• Title/Summary/Keyword: Gas Range

Search Result 2,990, Processing Time 0.029 seconds

The Effects of Using Common Oversized Cookware for Portable Butane Gas Range (상용 과대 불판 사용이 이동식 부탄 연소기에 미치는 영향)

  • Kim, Sooik;Keum, Kuk Bin;Yu, Byeonghun;Lee, Seungro;Kim, Young-gu;Lee, Chang Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.107-109
    • /
    • 2014
  • Through the economic development, people enjoying the camping and demand of camping goods are increasing since they have free time. So they use portable butane gas range outdoor. In addition to that, many restaurants that offer hotpot or meat in Korea use portable butane gas ranges for their convenience. But 19% of gas accidents are using portable butane gas range, 13.7% of them are using oversized cookware. Despite the high accident rate, there is no safety standards about portable butane gas range using oversized cookware. Therefore we conducted to measure temperature and pressure of portable butane gas ranges for reforming safety standards. As a result. we confirmed relation between bottom temperature of the portable butane gas barrel and pressure of the butane gas. Also we confirmed that portable butane gas ranges operate safely when bottom temperature of the portable butane gas barrel is bellow $50^{\circ}C$.

  • PDF

A Study on Improvement of Safety Standards for Commercial Gas Burning Appliances (업무용대형연소기 안전기준 개선방안 연구)

  • Choi, Suel-Ki;Ahn, Hyun-Soo;Lee, Chang-Eon;Kim, Young-Gu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.309-310
    • /
    • 2014
  • Commercial gas burning appliances are classified by KGS AB338. Even though there are many types of gas appliances with different purposes and uses, common standards are applied to the appliances. Manifold of commercial gas range could often be corroded by salt water. Gas leaks and accidents could be occurred by the corrosion. According to suggestion of detailed material standards for manifold of commercial gas range, it could help to use safely and prevent gas accidents.

  • PDF

Empirical Study on Stereotype for Burner-Control Relationship of Four-Stove Gas Range for Koreans

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.463-467
    • /
    • 2012
  • This study aims to empirically investigate population stereotype of burner-control linkage of four-stove gas range for Koreans. Background: The previous studies' results for gas range stereotypes were different depending upon methods adopted, i.e., whether using questionnaires, computer simulation or physical models. It is known that the physical model experiment should not be methodologically replaced by the computer simulation or paper-and-pencil tests. Stereotype of gas range for Koreans was surveyed based on questionnaires, but has not been dealt with by using physical models. Method: An experiment was conducted to investigate stereotype of four-burner gas range, in which 32 subjects participated and a real gas range available in the market was bought and used. Four types of burner-control linkage were used as independent variable, and reaction time as dependent variable. Results: ANOVA revealed that four types of burner-control linkage and subjects' gender were not significant on reaction time. Duncan's multiple range test showed that reaction times for type III was significantly lower than those for the other three types of burner-control linkage(${\alpha}$=0.05). Conclusion: It is concluded based on the results of this study that stereotype of gas range for Koreans is type III. This is in agreement with results of existing studies using questionnaire survey, while different from those based on physical models. Application: The results of this study would be useful as an ergonomic guideline when designing gas ranges or similar equipments for minimizing operation errors.

Prediction of the ventilation performance in a kitchen with various locations of gas range and window (가스렌지와 창문위치에 따른 주방 배기성능 예측)

  • 김경환;이재헌;박명식;이대우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

Stereotype and Effective Cues for Burner-Control Relationship of Four-Stove Range (4구 가스레인지 버너-조종장치 연결에 대한 스테레오타이프 및 효과적 암시 신호)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.2
    • /
    • pp.118-123
    • /
    • 2011
  • This study aims to investigate stereotype and effective cue presentation methods for burner-control relationship of four-stove range for Korean. A total of 381 subjects(male : 262, female : 119) were surveyed using questionnaire, in which eight gas range models drawn by 3-D Max 2010 were presented. The gas range models were labeled by signs(☆#${\triangle}{\square}$) to eliminate suggestive effect of sequential codes such as alphabets and numbers. The results showed that the stereotype was significantly affected by occupation(p < 0.10), but not by subjects' gender and age(p > 0.39). The stereotype of four-burner gas range for Korean was the same as that of Chinese, while the stereotype was different from that of American. The cues with rectangular-shaped arrangements identical or similar to those of burners were effective to relate burners to corresponding controls. The diamond-shaped cues and burner arrangements were not appropriate for representing burner-control relationship of four-stove gas range. These findings would be used as a basic guideline when designing four-burner gas range or similar equipments.

The development and Performance test of the Cook Top type Gas valve for the slim-line style Gas Range (슬림라인형 가스레인지용 쿡탑형 가스 밸브의 개발과 작동 성능 검증)

  • Kim, Sang-Ju;Lee, Sang-Cheol;Ju, Kwang-Myung;Lee, Han-Jong;Chang, In-Bae
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.568-572
    • /
    • 2003
  • The height of valve body is limited to 30mm in the cook-top style gas valves for the domestic gas ranges. But the all the safety specifications of KS should be fulfilled and the magnetic power unit(MPU) should be installed in the valve body for the safety reason. The length of MPU body is longer than the 30mm that it should be located in the square direction of the knob shaft and therefore the implementation of the lever mechanism to transmit the press motion of the knob to the MPU valve is very difficult. In this paper, the hinged lever with inclined plate is used to transmit the press motion of the knob to the MPU valve. The analysis of the gas flow with using the commercial software of FLOW-3D shows that the gas flow capacity is fit for the domestic gas range. The performance and responsibility of the valve is tested for the mass production and the test results shows that the valve can be installed in the commercial gas range.

  • PDF

The Dependence on the Gas Pressure in SF6 Molecular Gas (SF6분자가스의 압력 의존도)

  • Jeon, Byung-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.816-820
    • /
    • 2007
  • We measured the electron drift velocity, W, in 0.5% $SF_6-Ar$ mixture over the E/N range from 30 Td to 300 Td and gas pressure range from 0.1 to 0.5 Torr by the double shutter drift tube with a variable drift distance, and calculated over the same E/N and gas pressure range by using the two-term approximation of the Boltzmann equation. The measured and calculated values at different gas pressure at each E/N was appreciable dependence in the results on the gas pressure.

The analysis of dependence on the gas number density in $SF_{6}$-Ar mixtures ($SF_{6}$-Ar혼합가스에서의 압력 의존도 해석)

  • 전병훈;하성철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.248-251
    • /
    • 2002
  • We measured the electron drift velocity, W, in 0.5% $SF_{6}$-Ar mixture over the E/N range from 30 Td to 300 Td and gas pressure range from 0.1 to 8 Torr by the double shutter drift tube with a variable drift distance. This coefficient in the mixture was calculated over the same E/N and gas pressure range by using the two-term approximation of the Boltzmann equation. And the measured and calculated values at different gas number density at each E/N was appreciable dependence in the results on the gas number density,

  • PDF

The Study on Evaluation of Human Body Injury by Explosion of Portable Butane Gas Range (부탄연소기 폭발로 인한 인체 상해 평가에 관한 연구)

  • Kim, Eui Soo;Shim, J.H.;Kim, J.P.;Park, N.K.
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.60-67
    • /
    • 2016
  • The gas leak and explosion accident is able to give a fatal injury to nearby people from the explosion center and interest in effect of the explosion on the human body is increased. Accidents by Portable Butane Gas Range of a gas explosion accident occupy the most share. As a result, the injury on the human body frequently occur. However, It is situation that are experiencing difficulties in consequence analysis of explosion accidents owing to shortage of explosion power data and lack of research on the effect of the human body by the gas explosion. This paper acquire human injury data by performing the actual explosion experiment with Portable Butane Gas Range and evaluate power by explosion and effect of explosion on the human body to perform explosion simulation with LS-DYNA program. It is intended to contribute to the exact cause of the accident investigation and the same type of accident prevention.

Source Emission Rate on Air Pollutants from Portable Gas Range and Optimal Ventilation Rate in Indoor Environment (휴대용 가스렌지 연소에 의한 공기오염물질의 발생량 및 실내환경의 필요 환기량)

  • Yim, Sung-Kuk;Kim, Young-Hee;Yang, Won-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.92-97
    • /
    • 2007
  • A series of source tests were conducted to characterize emissions of nitrogen oxide(NOx, NO, $NO_2$), carbon mon oxide(CO), carbon dioxide$(CO_2)$ and total VOCs from portable combustion devices in steady-state using well-mixed chamber. Since use of portable gas range is widespread in houses and restaurants in Korea, it is important to characterize the emission of air pollutants and suggest optimum ventilation rate. Ranges of emission rates of air pollutants from portable gas ranges were $NO \;0.551\sim0.939mg/hr,\;NO_2\;0.354\sim1.080mg/hr,\;NO_x\;1.207\sim1.631mg/hr,\;CO\;1.389\sim4.21mg/hr,\;CO_2\;2426.823\sim2973.495mg/hr$, and VOCs $0\sim0.119mg/h$. Mean of personal exposure and indoor environment level of $NO_2$ by combustion of portable gas range were 74.7 ppb and 65.4 ppb, respectively, suggesting persons using portable gas range in houses and restaurants might be highly exposed. Required ventilation rate to control the air pollutants emitted from portable gas range was maximumly $3.131m^3/hr$ on the basis of $NO_2$ indoor air quality standard.