• Title/Summary/Keyword: Gas Alarm

Search Result 81, Processing Time 0.022 seconds

A Study on Risk Analysis and Acident Prevention Heater Interlock By-pass (Heater interlock by-pass로 인한 위험분석 및 사고방지에 대한 연구)

  • Son Jae-geun;Park Kyo-Shik;Kang Tae-Yeon;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.24-27
    • /
    • 2003
  • In this paper it was investigated 15 heaters of CDU plant heater, NCC plant heater, CO plant heater, Aromatic plant heater and so on while running in our country. It was also analysed the standard of operation procedure, the action in alarm, the interlock system, the operating situation of the interlock by-pass and major accident about the heater and so on. This paper presents the installation of the on-line monitoring, the additional installation of the local pressure gauge and temperature gauge, the check in starting operation,'the management of the interlock by-pass, the change of manufacturer causing the disorder of instrument sensor, the management method of DCS alarm for methods of the interlock prevention and facilities improvement. It was few information about the heater interlock in the inside and outside of the country We mainly have studied with reflecting the opinion of the operator and manager on site, the sheet of process trouble and operation procedure and so on. we think that the accident relating to the interlock will significantly reduce if the companies apply the conclusion of this study(i.e. methods of the interlock prevention and facilities improvement).

  • PDF

A Study on the Effectiveness of Gas Safety Devices for Domestic (가정용 가스안전기기의 실효성에 관한 연구)

  • Jo Young-Do;Lee Kyung-Sik;Jang Sung-Dong;Kim Ji-Yun
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.62-69
    • /
    • 2001
  • Gas safety devices are very effective to prevent catastrophic gas accident in domestic. The safety devices are included in domestic gas equipment such as extinguishing safety device and adapted at pipeline such as fuse cock, shut off device with gas alarm and so forth. In spite of using those safety devices, a few hundreds of gas accident was happened annually in residential house. In this study, we analysed systematically the domestic accidents which was happened in five years using fault tree analysis(FTA) method and analysed the effectiveness of individual safety device. And also, it was suggested that the rate of accident was decreased quantitatively by increasing safety device which is adapted in domestic. By analysis of 769 gas accidents in domestic, the order of effectiveness of safety device to prevent domestic gas accident was the multi-functional gas-safe-meter(micom-meter), fuse cock, gas leak alarm and CO alarm. If the above four kind of safety device are adapted to every house, about $59\%$ of accident will be reduced and the most of catastrophic gas accident will be Prevented in domestic.

  • PDF

Study on the Criterion and Algorithm for On-line Dissolved Gas of a Power Transformer (전력용 변압기 온라인 유중가스 진단기준치 및 알고리즘에 관한 연구)

  • Kweon Dongjin;Kwak Joosik;Kwak Heero;Kim Jaechul;Chin Sunbm
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.206-212
    • /
    • 2005
  • In this paper, criterion and algorithm for on-line dissolved gas of a Power transformer are studied. For the initial diagnosis of a power transformer, the on-line dissolved gas analysis is one of the most important and acceptable item to preventively diagnose a power transformer. But the criterion and algorithm of this item are not established yet in korea. In this paper, criterion and alarm level of the on-line dissolved gas analysis are based on the analysis of on-line data of operating transformers, Korea industrial standard and operation manual for a power transformer as well as accumulated data of the preventive diagnosis systems which have been operated at nine substations of Korea Electric Power Co.(KEPCO) since 1997, Therefore, the criterion and alarm level proposed in this paper are to be well suitable and are adaptable for the domestic operational environments and conditions of the power transformer. Considering that the conventional diagnosis system is capable only of accumulating and monitoring data of the power transformer operation, the criteria and the algorithms make it possible to accomplish an ultimate goal of the preventive diagnosis system. It is expected, therefore, that they will have a beneficial effect on broad applications of the preventive diagnosis system and the achievement of manless substation system in the future.

Notify boiling water by using TMP36 sensor

  • Lau, Shuai
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.8-10
    • /
    • 2016
  • These days, citizens have a lot of ways to get access to IT. In the past, they tended to neglect IT that was thought to be difficult. But, currently, everyone can manufacture and get access not only software but also hardware when he has an idea. Arduino is used. Rinnai had recently released new product named Smart Sensor Range. Safe consumer who gave priority to the safety made new trend gave attention to fire prevention and smart sensor range. The ones who buy gas range prefer safety to economic advantage and/or fire power. The safety system does not always prevent fire accident. This study makes design and produces alarm that perceives temperature of pot when boiling. Not only temperature sensor but also alarm sensor was used to make alarm of boiling water and to give convenient living life. The arduino can be used at practical life to make products for various kinds of people. The invention can give convenience to housewives at kitchen, children and many persons making use of gas range. Another function can be added to develop. This arduino can develop a lot of products by using the study and other designs.

Development of City Gas Sensors (도시가스 센서의 개발)

  • 이덕동;최동한;손병기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.4
    • /
    • pp.407-416
    • /
    • 1988
  • Thick film city gas sensors were fabricated using \ulcornerFe2O3 and \ulcorner-Fe2O3 as raw materials. Their electrical properties and sensitivity characteristics were investigated and the surface conditions for various firing temperatures were analyzed. The fabricated devices exhibited high sensitivity to butane gas(75~80% n 1, 000ppm butane ambient). Also they showed good selectivity and long-term stability. A city gas alarm system using fabricated sensors was made for the practical application.

  • PDF

A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System (가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰)

  • Yu, Won-Ju;Lee, Seong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.75-82
    • /
    • 2010
  • Gas turbines for power generating operate in a very high temperature condition and use natural gas for fuel. For this reason, many cases of damage happen at hot gas parts which are severely affected by high temperature gas and many cases of explosion occur by fuel gas. So a lot of efforts should be made to prevent hot gas parts damage and gas explosion accidents. Though there are many damage cases and explosion accidents, it is very difficult to find out the root causes of hot gas parts damage caused by gas explosion due to gas leakage in the heat exchanger for air cooling and gas heating. To prevent gas turbine from damage caused by gas explosion, removal of leakage gas from gas turbine is inevitably required before firing the gas turbine and installing alarm systems is also required for detecting gas leakage at stop valve to turbine while shut down.

A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System (가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰)

  • Yu, Won-Ju;Lee, Seong-Hyun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.81-95
    • /
    • 2010
  • Gas turbines generating power operate in high temperature condition and use natural gas as fuel. For that reason, there are many cases where damage is done to the hot gas parts caused by the high temperature and many accidents occur like gas explosions, then various efforts are needed to maintain the hot gas parts and prevent accidents. It is difficult to find the root causes of damage to the hot gas parts from the gas explosion caused by gas leakage through rotor cooling air line from fuel gas heat exchanger during the shut down. To prevent gas turbine from damage, removal of gas leakage inside of gas turbine is required by purging the turbine before firing, improving the fuel gas heating system and installing alarm systems for detecting gas leakage from stop valve to turbine while the gas turbine has shut down.

  • PDF

Design and Implementation of Gas Leakage Alarm IoT System for Safety Helmet (안전모 장착용 가스 누출 경보 IoT 시스템 설계 및 구현)

  • Ju, Yong-Min;Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1411-1416
    • /
    • 2018
  • Currently, most of the industrial areas like chemistry, manufacturing, shipbuilding, and steel, perform the work related to gas, and the staffs who are in charge of this work have a risk of suffocation without cognizing incidents like gas leak. For example, when the nitrogen gas leaked in 2015 at Paju, two people were killed and four people were injured. In 2018 at Pohang, four workers were suffocated to death from nitrogen gas. In order to solve this problem, this study realized the system in which workers could immediately cognize the gas leak and also deliver the situation to the staff in charge of safety at the same time, by installing the IoT device composed of gas sensor and communication module on the safety helmet that should be worn by field workers. This study is expected to be able to reduce the casualties caused by gas leak in industrial sites.

Design and Implementation of Vehicle Internal Alarm System using Raspberry-pie Multi-sensor

  • Choi, MyeongBok;Park, SungKon
    • International journal of advanced smart convergence
    • /
    • v.7 no.2
    • /
    • pp.112-118
    • /
    • 2018
  • This paper describes the design and implementation of a vehicle internal alarm system using raspberry-pie and gas sensor. It provides a notification system for sleepiness during driving, a driving time notification system and a smoking detection system. We coded using 'Python'. And we use 'MySQL' and 'PHP' to build the necessary servers and web pages for gathering sensing data and monitoring. The developed system was tested by several methods. All experiments showed satisfactory response signals and detected with immediate responses.

A Study on Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Oh, Jeong-Seok
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF