• Title/Summary/Keyword: Gamma test

Search Result 1,070, Processing Time 0.03 seconds

Cognitive Abilities and Auditory Event Related Potentials in Patients with Schizophrenia (조현병 환자의 인지기능과 뇌 사건유발전위의 관계)

  • Kim, Ka-Young;Min, Jung-Ah;Chae, Jeong-Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.19 no.3
    • /
    • pp.115-120
    • /
    • 2012
  • Objectives : Event-related potentials have been suggested as an objective marker for brain functions in psychiatric disorders. This study was aimed to investigate the relationships between P300, the mismatch negativity (MMN), the loudness dependence of the auditory evoked potential (LDAEP), demographic and clinical variables including neurocognitive abilities in patients with schizophrenia. Methods : P300, the MMN, and the LDAEP were measured and the Korean Stroop color-word test (K-stroop test) and the Wisconsin Card Sorting Test (WCST) were performed in 43 patients with schizophrenia. The relationship of the latency and amplitude of P300 and the MMN as well as regression slope of the LDAEP with demographic and clinical variables were analyzed by t-test and correlation analyses for categorical and continuous variables, respectively. Results : After controlling for age, the latency of central (Cz) and parietal (Pz) P300 posivitively correlated with GAF at admission (Cz ; ${\gamma}$ = 0.385, p = 0.047, Pz ; ${\gamma}$ = 0.421, p = 0.029). The amplitude of parietal P300 correlated with the correction rate of the K-stroop test (${\gamma}$ = 0.575, p = 0.002). In addition, the frontal (Fz) P300 latency tended to negatively correlated with the correction rate of the WCST (${\gamma}$ = -0.371, p = 0.057). Conclusions : Our findings suggest that the values of P300 latency and amplitude might be correlated with GAF at admission and working memory measured by the K-Stroop test and the WCST. Meanwhile, the MMN and the LDAEP did not correlate with demographic and clinical variables. These results support the results of previous studies showing associations with P300 and impaired cognitive ability.

Genotoxicological Safety of Gamma-Irradiated Kwamegi(semi-dried Colobabis seira) (감마선 조사된 과메기의 유전독성학적 안전성 평가)

  • 육홍선;정영진;송현파;이주운;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.1
    • /
    • pp.182-192
    • /
    • 2004
  • Gamma irradiation at 5 and 10 kGy was applied to Kwamegi (semi-dried Colobabis seira) for their possible hygiene quality and carried out genotoxicological safety. In vitro genotoxicological safety of each 5 and 10 kGy-irradiated Kwamegi was evaluated by Salmonella typhimurium (TA98, TA100, TA1535 and TA1537) and E. coli WP2 uvrA reversion assay, SOS chromotest (Escherichia coli PQ37) and chromosome aberration test (Chinese hamster lung fibroblast cells) in the absence and presence of an exogenous metabolizing system (S9 mix). Gamma-irradiated samples were not different from nonirradiated-control to respective in vitro tests. And in vivo micronucleus test using ICR mice (male) micronucleus was not observed. Kwamegi exposed to 10 kGy-gamma ray revealed negative results in these three in vitro mutagenetic tests and in vivo micronucleus test up to 10,000 $\mu\textrm{g}$/plate, respectively. The results indicated that 5 and 10 kGy gamma-irradiated Kwamegi (semi-dried Colobabis seira) did not have mutagenicity.

Influence of the Chemical Treatment of Bamboo Fiber (BF) on Physical Properties of BF and PP/BF Composites (대나무 섬유(BF) 및 PP/BF 복합체의 물성에 미치는 BF의 화학적 처리의 영향)

  • Lee, Beom Hee;Jeong, Da Sol;Kim, Cheol Woo;Park, Seong Ho;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.168-175
    • /
    • 2018
  • In order to investigate the effect of the chemical treatment of bamboo fiber on physical properties of polypropylene (PP)/bamboo fiber (BF) composites, silane coupling agents such as ${\gamma}$-aminopropyltriethoxysilane (APS), ${\gamma}$-glycidoxypropyl-trimethoxysilane (GPS) and ${\gamma}$-mercaptopropyltrimethoxysilane (MRPS) were applied to BF and alkaline treated BF. Morphological properties of the chemically treated BF were confirmed by optical microscope and SEM measurements, and chemical structure changes were confirmed by FT-IR and EDS. TGA results showed that the thermal stability of silane treated BF increased. Based on the analysis of a universal testing machine and an Izod impact test, the flexural and impact properties of PP/silane treated BF composites showed higher values than those of PP/BF composites. The enhancement of interfacial adhesion properties of the PP/BF composite was checked from SEM images of the fracture of specimens after the tensile test.

Modelling land surface temperature using gamma test coupled wavelet neural network

  • Roshni, Thendiyath;Kumari, Nandini;Renji, Remesan;Drisya, Jayakumar
    • Advances in environmental research
    • /
    • v.6 no.4
    • /
    • pp.265-279
    • /
    • 2017
  • The climate change has made adverse effects on land surface temperature for many regions of the world. Several climatic studies focused on different downscaling techniques for climatological parameters of different regions. For statistical downscaling of any hydrological parameters, conventional Neural Network Models were used in common. However, it seems that in any modeling study, uncertainty is a vital aspect when making any predictions about the performance. In this paper, Gamma Test is performed to determine the data length selection for training to minimize the uncertainty in model development. Another measure to improve the data quality and model development are wavelet transforms. Hence, Gamma Test with Wavelet decomposed Feedforward Neural Network (GT-WNN) model is developed and tested for downscaled land surface temperature of Patna Urban, Bihar. The results of GT-WNN model are compared with GT-FFNN and conventional Feedforward Neural Network (FFNN) model. The effectiveness of the developed models is illustrated by Root Mean Square Error and Coefficient of Correlation. Results showed that GT-WNN outperformed the GT-FFNN and conventional FFNN in downscaling the land surface temperature. The land surface temperature is forecasted for a period of 2015-2044 with GT-WNN model for Patna Urban in Bihar. In addition, the significance of the probable changes in the land surface temperature is also found through Mann-Kendall (M-K) Test for Summer, Winter, Monsoon and Post Monsoon seasons. Results showed an increasing surface temperature trend for summer and winter seasons and no significant trend for monsoon and post monsoon season over the study area for the period between 2015 and 2044. Overall, the M-K test analysis for the annual data shows an increasing trend in the land surface temperature of Patna Urban.

Preliminary Uncertainty Analysis to Build a Data-Driven Prediction Model for Water Quality in Paldang Dam (팔당댐 유역의 데이터 기반 수질 예측 모형 구성을 위한 사전 불확실성 분석)

  • Lee, Eun Jeong;Keum, Ho Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.24-35
    • /
    • 2022
  • For water quality management, it is necessary to continuously improve the forecasting by analyzing the past water quality, and a Data-driven model is emerging as an alternative. Because the Data-driven model is built based on a wide range of data, it is essential to apply the correlation analysis method for the combination of input variables to obtain more reliable results. In this study, the Gamma Test was applied as a preceding step to build a faster and more accurate data-driven water quality prediction model. First, a physical-based model (HSPF, EFDC) was operated to produce daily water quality reflecting the complexity of the watershed according to various hydrological conditions for Paldang Dam. The Gamma Test was performed on the water quality at the water quality prediction site (Paldangdam2) and major rivers flowing into the Paldang Dam, and the method of selecting the optimal input data combination was presented through the analysis results (Gamma, Gradient, Standar Error, V-Ratio). As a result of the study, the selection criteria for a more efficient combination of input data that can save time by omitting trial and error when building a data-driven model are presented.

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.

Design of Bayesian Zero-Failure Reliability Demonstration Test for Products with Weibull Lifetime Distribution (와이불 수명분포를 갖는 제품에 대한 베이지안 신뢰성 입증시험 설계)

  • Kwon, Young Il
    • Journal of Applied Reliability
    • /
    • v.14 no.4
    • /
    • pp.220-224
    • /
    • 2014
  • A Bayesian zero-failure reliability demonstration test method for products with Weibull lifetime distribution is presented. Inverted gamma prior distribution for the scale parameter of the Weibull distribution is used to design the Bayesian test plan and selecting a prior distribution using a prior test information is discussed. A test procedure with zero-failure acceptance criterion is developed that guarantee specified reliability of a product with given confidence level. An example is provided to illustrate the use of the developed Bayesian reliability demonstration test method.

A study on the Immune Response of Salmonella Typhi Inactivated by Gamma Ray (전리방사선(電離放射線)에 의(依)하여 불활화(不活化)된 Salmonella typhi의 면역반응(免疫反應) 연구(硏究))

  • Rhee, Kang-Soon;Min, Bong-Hee;Chang, Chung-Soon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.8 no.1
    • /
    • pp.37-42
    • /
    • 1973
  • For the preparation of non-infective vaccine against typhoid fever, the authors had carried out an investigation on the possibilities of using $^{60}Co\;{\gamma}$-ray irradiation for the inactivation of Salmonella typhi Ty 2. The following results were obtained. 1) Chicks shortly after hatching were higher susceptible than mice to intracerebral injection with S. typhi. 2) In safety test on experimental animal, $^{60}Co\;{\gamma}$-ray irradiated vaccines demonstrated no clinical symptom while the phenol treated vaccines revealed several cases of narcosis by intraperitoneal injection in chicks. 3) The rabbit antisera immunized with $^{60}Co\;{\gamma}$-ray irradiated and phenol treated vaccine revealed almost same agglutinin titers to each other. 4) In potency test in chicks, there was no significance in the protective capacity between $^{60}Co\;{\gamma}$-ray irradiated and phenol treated vaccines.

  • PDF

DESIGN AND APPLICATION OF A SINGLE-BEAM GAMMA DENSITOMETER FOR VOID FRACTION MEASUREMENT IN A SMALL DIAMETER STAINLESS STEEL PIPE IN A CRITICAL FLOW CONDITION

  • Park, Hyun-Sik;Chung, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.349-358
    • /
    • 2007
  • A single-beam gamma densitometer is utilized to measure the average void fraction in a small diameter stainless steel pipe under critical flow conditions. A typical design of a single-beam gamma densitometer is composed of a sealed gammaray source, a collimator, a scintillation detector, and a data acquisition system that includes an amplifier and a single channel analyzer. It is operated in the count mode and can be calibrated with a test pipe and various types of phantoms made of polyethylene. A good average void fraction is obtained for a small diameter pipe with various flow regimes of the core, annular, stratified, and bubbly flows. Several factors influencing the performance of the gamma densitometer are examined, including the distance between the source and the detector, the measuring time, and the ambient temperature. The void fraction is measured during an adiabatic downward two-phase critical flow in a vertical pipe. The test pipe has an inner diameter of 10.9 mm and a thickness of 3.2 mm. The average void fraction was reasonably measured for a two-phase critical flow in the presence of nitrogen gas.