• 제목/요약/키워드: Gamma spectroscopy

검색결과 288건 처리시간 0.041초

Preparation of Modified Hollow Polypropylene Membrane and Their Adsorption Properties of ${\gamma}$-Globulins

  • Hwang, Taek-Sung;Park, Jin-Won
    • Macromolecular Research
    • /
    • 제11권5호
    • /
    • pp.347-351
    • /
    • 2003
  • The hydrophobic ligand-containing hollow polypropylene (PP) membranes were synthesized by the mutual radiation induced graft copolymerization with glycidylmethacrylate (GMA) onto hollow PP membrane followed by the subsequent functionalization with L-phenylalanine. FT-IR, elemental analysis and UV spectroscopy were utilized to characterize copolymer composition, and degree of grafting, functionalization conversion and ${\gamma}$-globulins adsorption. The degree of grafting on the PP surface increased with the reaction time and total dose of E-beam. In the subsquent functionalization, the amount of L-phenylalanine increased with the increase in the degree of grafting and the degree of conversion was about 30%. The ${\gamma}$-globulins adsorption experiments showed that adsorption capacity had a maximum value at pH 8. The ${\gamma}$-globulins adsorption capacity in the basic pH region was higher than in the acidic pH region.

방사선 처리에 의한 선충 방제 효과 (Experimental Study on Physical Control of Nematodes Using The Ionizing Radiation)

  • 이재광;유대현;이면주
    • 한국환경과학회지
    • /
    • 제14권12호
    • /
    • pp.1113-1117
    • /
    • 2005
  • Gamma-ray treatment was used to exterminate nematodes, which were harmful to agriculture When gamma-ray at the dose range of $5\~75$ kGy was irradaidated, nematodes were reduced by $40\~50\%$ When irradiated over 30 kGy, almost nematodes were non-mobile and fluorochromatic reactions showed that $60\;\~80\%$ of nematodes with non-mobility died after irradiation. The results of electron spin resonance spectroscopy suggested that radicals generated by radiolysis could damage to nematodes.

Characterizations of Novel Poly(aspartic acid) Derivatives Conjugated with γ-Amino Butyric Acid (GABA) as the Bioactive Molecule

  • Kim, Seung-Il;Son, Chang-Mo;Jeon, Young-Sil;Kim, Ji-Heung
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권12호
    • /
    • pp.3025-3030
    • /
    • 2009
  • Novel poly(aspartic acid) derivatives conjugated with $\gamma$-amino butyric acid, GABA, moieties, and their amphiphilic analogs were synthesized and characterized. The chemical structures of these polymers were confirmed by FT-IR and $^1H$ NMR spectroscopy. Their physicochemical properties in aqueous media were characterized by electrophonetic light scattering spectrophotometry (ELS), acid-base titration, and UV-spectroscopy. In addition, the in vitro cell activity of the GABA-conjugated polymer was examined. These results indicated that GABA-conjugated poly(aspartic acid) derivatives showed cell-growth activity and nanoparticle formation of a suitable size within aqueous media. These polymers have potential application in the cosmetic and pharmaceutical fields.

Background reduction by Cu/Pb shielding and efficiency study of NaI(TI) detector

  • Ramadhan, Revink A.;Abdullah, Khairi MS.
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.462-469
    • /
    • 2018
  • The background spectrum of a $3^{{\prime}{\prime}}{\times}3^{{\prime}{\prime}}$ NaI(Tl) well-type scintillation SILENA detector was measured without shielding, in 6 cm thick lead shielding, and with 2 mm thick electrolytic copper covering the detector inside the lead shielding. The relative remaining background of the lead shield lined with copper was found to be ideal for low-level environmental radioactive spectroscopy. The background total count rate in the (20-2160 KeV) was reduced 28.7 times by the lead and 29 times by the Cu + Pb shielding. The effective reduction of background (1.04) by the copper mainly appeared in the energy range from X-ray up to 500 KeV, while for the total energy range the ratio is 1.01 relative to the lead only. In addition, a strong relation between the full-energy peak absolute efficiency and the detector well height was found using gamma-ray isotropic radiation point sources placed inside the detector well. The full-energy peak efficiency at a midpoint of the well (at 2.5 cm) is three times greater than that on the detector surface. The energy calibrations and the resolution of any single energy line are independent of the locations of the gamma source inside or outside of the well.

Development of a gamma irradiation loop to evaluate the performance of a EURO-GANEX process

  • Sanchez-Garcia, I.;Galan, H.;Nunez, A.;Perlado, J.M.;Cobos, J.
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1623-1634
    • /
    • 2022
  • A new irradiation loop design has been developed, which provides the ability to carry out radiolytic resistance studies of extraction systems simulating process relevant conditions in an easy and simple way. The step-by-step loop configuration permits an easy modification of settings and has a relative low volume requirement. This irradiation loop has been initially set up to test the main EURO-GANEX process steps: the lanthanide (Ln) and actinide (An) co-extraction followed by the transuranic (TRU) stripping. The performance and changes in the composition have been analyzed during the irradiation experiment by different techniques: gamma spectroscopy and ICP-MS for the extraction and corrosion behavior of the full system, and HPLC-MS and Raman spectroscopy to determine the degradation of the organic and aqueous solvents, respectively. The Ln and An co-extraction step and the corrosion that occurred during the first irradiation step revealed the favorable expected results according to literature. The effects of acidity changes occurred during the irradiation process, the presence of stainless corrosion products in solution as well as the new possible degradation compounds have been explored in the An stripping step. The results obtained demonstrate the importance of developing realistic irradiation experiments where different factors affecting the performance can be easily studied and isolated.

초미세 나노분말 γ-Fe2O3의 초상자성 특성연구 (Superparamagnetic Properties of γ-Fe2O3 Nanoparticles)

  • 이승화;이재광;채광표;안성용
    • 한국자기학회지
    • /
    • 제20권5호
    • /
    • pp.196-200
    • /
    • 2010
  • Sol-gel 법을 이용하여 초상자성 나노 입자 $\gamma-Fe_2O_3$를 제조하였다. 입자의 크기 및 자기적 성질을 x-선 회절법(XRD), Mossbauer 분광법, 진동시료 자화율 측정기(VSM)를 이용하여 연구하였다. x-선 회절 실험결과 150 이상에서 열처리한 입자는 순수한 cubic spinel 구조를 가지며, $150^{\circ}C$에서 열처리한 $\gamma-Fe_2O_3$의 평균입자 크기는 7 nm로다. Mossbauer 분광실험으로 $150^{\circ}C$에서 열처리한 입자는 상온에서 초상자성의 특성을 가지고 있음을 알 수 있었으며 초상자성의 특성을 잃어버리는 차단온도 $T_B$$183^{\circ}C$로 결정하였으며, 또한 자기이방성상수 K = $1.6{\times}10^6erg/cm^3$의 값을 얻었다. $150^{\circ}C$에서 열처리한 $\gamma-Fe_2O_3$의 VSM 측정 결과로부터 $150^{\circ}C$에서 열처리한 $\gamma-Fe_2O_3$의 경우 상온에서 초상자성의 특성을 확인 할 수 있었다.

The Effect of Gamma Irradiation on PLGA and Release Behavior of BCNU from PLGA Wafer

  • Lee, Jin-Soo;Chae, Gang-Soo;Gilson Khang;Kim, Moon-Suk;Cho, Sun-Hang;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • 제11권5호
    • /
    • pp.352-356
    • /
    • 2003
  • The objectives of this study were to investigate the influence of gamma irradiation for sterilization on poly(D,L-lactide-co-glycolide) (PLGA) with different molecular weight and the effect of gamma irradiation on the release behavior of 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU, carmustine) from PLGA wafer with various irradiation doses. The effect of gamma irradiation on PLGA was evaluated by gel permeation chromatography (GPC), differential scanning calorimetry (DSC), and electron paramagnetic resonance (EPR). The weight average molecular weight (M$_{w}$) and glass transition temperature (T$_{g}$) of PLGA decreased after gamma irradiation. The extent of M$_{w}$ reduction was dependent on irradiation dose and PLGA molecular weight. Using EPR spectroscopy, we successfully detected gamma irradiation induced free radicals in PLGA. The gamma irradiation increased the release rate of BCNU from PLGA wafer at applied irradiation doses except 2.5 Mrad of irradiation dose in this study.study.