• Title/Summary/Keyword: GMR-SV 소자

Search Result 24, Processing Time 0.031 seconds

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device (마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구)

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of $RBC+{\mu}Beads$ is controlled by the electrical AC input signal. The $RBC+{\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

Detection Characteristics of a Red Blood Cell Coupled with Micron Magnetic Beads by Using GMR-SV Device (GMR-SV 소자를 이용한 미크론 자성비드와 결합된 적혈구 검출 특성 연구)

  • Lee, Jae-Yeon;Kim, Moon-Jong;Lee, Sang-Suk;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.101-106
    • /
    • 2014
  • The glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(2.3 nm)/NiFe(3 nm)/IrMn(12 nm)/Ta(5.8 nm) GMR-SV (giantmagneto-resistance-spin valve) multilayer structure films with a magnetoresistance ratio (MR) of 5.0 % and a magnetic sensitivity (MS) of 1.5%/Oe was deposited by dc magnetron sputtering method. Also, GMR-SV device having a width of $7{\mu}m{\sim}8{\mu}m$ similar to the diameter of RBC (red blood cell) was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ dropped upon the GMR-SV device having MR = 1.06% and MS = 0.3 %/Oe, there is observed the variation of about included of a resistance value of ${\Delta}R=0.4{\Omega}$ and ${\Delta}MR=0.15%$ around a external magnetic field of -0.6 Oe. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property of hemoglobin inside of RBC combined to magnetic beads.

Properties of Exchange Bias Coupling Field and Coercivity Using the Micron-size Holes Formation Inside GMR-SV Film (GMR-SV 박막내 미크론 크기의 홀 형성을 이용한 교환결합세기와 보자력 특성연구)

  • Bolormaa, Munkhbat;Khajidmaa, Purevdorj;Hwang, Do-Guwn;Lee, Sang-Suk;Lee, Won-Hyung;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.117-122
    • /
    • 2015
  • The holes with a diameter of $35{\mu}m$ inside the GMR-SV (giant magnetoresistance-spin valve) film were patterned by using the photolithography process and ECR (electron cyclotron resonance) Ar-ion milling. From the magnetoresistance curves of the GMR-SV film with holes measuring by 4-electrode method, the MR (magnetoresistance ratio) and MS (magnetic sensitivity) are almost same as the values of initial states. On other side hand, the $H_{ex}$ (exchange bias coupling field) and $H_c$ (coercivity) dominantly increased from 120 Oe and 10 Oe to 190 Oe and 41 Oe as increment of the number of holes inside GMR-SV film respectively. These results were shown to be attributed to major effect of EMD (easy magnetic domian) having a region positioned between two holes perpendicular to the sensing current. On the basis of this study, the fabrication of GMR-SV applying to the hole formation improved the magnetoresistance properties having the thermal stability and durability of bio-device.

Fabrication and Characteristics of a Highly Sensitive GMR-SV Biosensor for Detecting of Micron Magnetic Beads (미크론 자성비드 검출용 바이오센서에 대한 고감도 GMR-SV 소자의 제작과 특성 연구)

  • Choe, Jong-Gu;Park, Gwang-Jun;Lee, Ju-Hyeong;Lee, Sang-Seok;Lee, Jang-Ro
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2012.11a
    • /
    • pp.146-148
    • /
    • 2012
  • 미크론 자성비드 검출용 바이오센서에 활용하는 GMR-SV 박막을 이온빔 스퍼터링 증착법으로 glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(t nm)/NiFe(3 nm)/FeMn(12 nm)/Ta(5.8 nm)의 구조를 갖도록 증착하였다. 비자성체 Cu의 두께가 3.0 nm에서 2.2 nm까지 얇아질수록 교환결합력은 증가하였으며 자기저항비는 다소 낮았다. 비자성체의 두께가 얇으면 반강자성체의 층간 교환작용이 강자성체의 고정층 뿐만 아니라 자유층의 스핀배열에도 영향을 주고 있음을 확인할 수 있었다. 또한 리소그래피 공정 과정을 거쳐 GMR-SV 소자를 제작하여 미트론 자기비드를 검출하였다. 여기서 자기비드를 떨어뜨리기 전과 후의 자기저항비, 교환결합력, 보자력은 각각 0.9%, 3 Oe, 2 Oe의 값을 나타내었다. 이것으로 미크론단위의 바이오센서로서 활용할 수 있는 가능성을 보여주었다.

  • PDF

Fabrication and Characteristics of a Highly Sensitive GMR-SV Biosensor for Detecting of Micron Magnetic Beads (미크론 자성비드 검출용 바이오센서에 대한 고감도 GMR-SV 소자의 제작과 특성 연구)

  • Choi, Jong-Gu;Lee, Sang-Suk;Park, Young-Seok
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.173-177
    • /
    • 2012
  • The multilayer structure of glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(t nm)/NiFe(3 nm)/FeMn(12 nm)/Ta(5.8 nm) as typical GMR-SV (giant magnetoresistance-spin valve) films is prepared by ion beam sputtering deposition (IBD). The coercivity and magnetoresiatance ratio are increased and decreased for the decrease of Cu thickness when the thickness of nonmagnetic Cu layer from is varied 2.2 nm to 3.0 nm. It means that the decrease of non-magntic layer is effected to the interlayer exchange coupling of pinned layer and the spin configuration array of free layer. For experiment of detecting and dropping of magnetic beads we used the GMR-SV sensor with glass/Ta/NiFe/Cu/NiFe/FeMn/Ta structure. From the comparison of before and after for the dropping status of magnetic bead, the variations of MR ratio, $H_{ex}$, and $H_c$ are showed 0.9 %, 3 Oe, and 2 Oe, respectively. The fabrication of GMR-SV sensor was included in the process of film deposition, photo-lithography, ion milling, and MR measurement. Further, GMR-SV device can be easily integrated so that detecting biosensor on a single chip becomes possible.

Shape Magnetic Anisotropy on Magnetic Easy Axis of NiFe/Cu/NiFe/IrMn Spin Valve Thin Film (NiFe/Cu/NiFe/IrMn 스핀밸브 박막소자의 자화 용이축에 따른 형상 자기이방성)

  • Choi, Jong-Gu;Kwak, Tae-Joon;Lee, Sang-Suk;Sim, Jung-Taek
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.35-40
    • /
    • 2010
  • The GMR-SV (giant magnetoresistance-spin valve) device depending on the micro patterned features according to two easy directions of longitudinal and transversal axes has been studied. The GMR-SV multilayer structure was Ta(5 nm)/NiFe(8 nm)/Cu(2.3 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm). The applied anisotropy direction of the GMR-SV thin film was performed under the magnitude of 300 Oe using by permanent magnet during the deposition. The size of micro patterned device was a $1\;{\times}\;18\;{\mu}m^2$ after the photo lithography process. In the aspects of the shape magnetic anisotropy effect, there are two conditions of fabrication for GMR-SV device. Firstly, the direction of sensing current was perpendicular to the magnetic easy axis of the pinned NiFe/IrMn bilayer with the transversal direction of device. Secondly, the direction of shape magnetic anisotropy was same to the magnetic easy axis of the free NiFe layer with the longitudinal direction of device.

Fabrication and Property of Water Level and Temperature Sensor for Medical Cooling System Using a Highly Sensitive GMR-SV Device (거대자기저항 스핀밸브 소자를 이용한 의료용 냉각기 수위 및 수온 센서의 제작과 특성)

  • Park, Kwang-Jun;Choi, Jong-Gu;Lee, Sang-Suk;Lee, Bum-Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.1
    • /
    • pp.32-36
    • /
    • 2011
  • We fabricated a sensor for measuring the water level and water temperature using GMR-SV (giant magnetoresistance-spin valve) device, simultaneously. It could be applied to the medical cooling system of the potassium titanylphosphate KTP) laser system for the therapy of a benign prostatic hyperplasia. The middle point of GMR-SV device was set to the near position of a high magnetic sensitivity with 2.8%/Oe. The sensitivity for the water level and water temperature of the fabricated sensor were $400\;m{\Omega}/mm$ and $100\;m{\Omega}/^{\circ}C$, respectively.

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.

Characteristics of Mineral Mg Dissolving Sensor in Edible Water using GMR-SV Device (거대자기저항 스핀밸브 소자를 이용한 음용수 미네랄 Mg 용해센서 특성 연구)

  • Lee, Ju-Hee;Kim, Da-Woon;Kim, Min-Ji;Park, Kwang-Seo;Kang, Joon-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.5
    • /
    • pp.174-179
    • /
    • 2008
  • The measurement dissolution sensor system using GMR-SV device with magnetic sensitivity of 0.8 %/Oe and Mg-film thick of 200 nm and Mg-foil thick of 50 mm was fabricated and characterized. During the water dissolving process of Mg-film and Mg-foil, the subtle variation of magnetic field by the decrease of current in solenoid was detected by the GMR-SV sensor. The variations of Mg bubble number and ORP as a function of time for three different kinds of edible, tap, and distilled water, are measured and compared. A After 45 min, the speed of fast dissolving Mg was shown the order of edible > tap > DI water. The variation of output magnetoresistance as a function of dissolved time of Mg-film and Mg-foil for edible water, which is composed of mineral content of $0.8{\sim}5.4\;mg/l$ was investigated. The response times for the dissolution in edible water were 5 min and 20 min, respectively. From the measurement of dissolving time and speed for Mg-film and Mg-foil using GMR-SV device, the mineral Mg sensor system in edible water can be possible to develop.