• 제목/요약/키워드: G-force

검색결과 1,527건 처리시간 0.033초

센서 동역학을 고려한 충격응답해석 (Analysis of Impact Responses Considering Sensor Dynamics)

  • 류봉조;권병희;안길영;오일성;이규섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.731-736
    • /
    • 2002
  • Impact is the most common type of dynamic loading conditions that give rise to impulsive forces and affects the vibrational characteristics of mechanical systems . Since the real impact force and acceleration at the contact surface are measured indirectly through the sensors, the measured outputs can be a little different from the real impact responses. In this study, the contact force model based on the Hertz law is proposed in order to predict the impact force correctly. To investigate the influence of the position of the sensor attached to the impacting bodies, the two kinds of sensors were used. Finally, the contact force model obtained by drop test was applied to predict the impact force between the moving part and the stopper in magnetic contactor.

  • PDF

미소 힘 측정을 위한 이중 전자기힘 보상방법 (Double Electro-Magnetic Force Compensation Method for the Micro Force Measurement)

  • 최임묵;우삼용;김부식;김수현
    • 한국정밀공학회지
    • /
    • 제20권2호
    • /
    • pp.104-111
    • /
    • 2003
  • Micro force measurement is required more frequently for a precision manufacturing and investment in fields of precision industries such as semiconductor, chemistry and biology, and so forth. Null balance method has been introduced as an alternative of a loadcell. Loadcells have advantages in aspects of low cost and easy manufacturing, but have also the limitation in resolution and sensitivity to environment variations. In this paper, null balance method is explained and the dominant parameters related to system performances are mentioned. Null position sensor, electromagnetic system and controller are investigated. Also, the characteristic experiment is carried out in order to estimate the resolution and the measurement range. In order to overcome the limitation by the drift of position sensor and the performance of controller, double electromagnetic force compensation method is proposed and experimented. After controlling and filtering, the resolution under $\pm$ 1mg and measurement range over 300g could be obtained.

기계식 심장판막의 충격력에 관한 실험적 연구 (An Experimental Study on the Impact Force of a Mechanical Heart Valve Prostheses)

  • 이정한;천길정
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.167-171
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force senfor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about $9{\sim}17N$. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF