• Title/Summary/Keyword: Future Signal

Search Result 732, Processing Time 0.032 seconds

Study on the Development of Multi-Path Ultrasonic Gas Flowmeter (전달 시간차 방식 다회선 초음파 가스 유량계 개발)

  • 황원호;박상국;이치환;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

Signal Transduction in Wound Pharmacology

  • Kim, Wiliam June-Hyun;George K. Gittes;Michael T. Longaker
    • Archives of Pharmacal Research
    • /
    • v.21 no.5
    • /
    • pp.487-495
    • /
    • 1998
  • Gorwth factors such as TGF-beta, PDGF and FGF are thought to play important roles in wound healing. However, thier biological activity and signal transduction during wound repair remain poorly understood. Growth factors are often ligands for receptor tyrosine kinase and receptor serine/threonine kinases. With recent advances in signal transduction by receptor kinases, we are beginning to understand the underlying mechanism of how growth factors may regulate cutaneous wound repair. In this paper, we will describe the pharmacological effects of growth factors on wound healing, and dscuss the potential underlying signaing mechanisms. thus, we hope to provide the basis for designing more specific therapeutics for wound healing in the near future.

  • PDF

Sample selection approach using moving window for acoustic analysis of pathological sustained vowels according to signal typing

  • Lee, Ji-Yeoun
    • Phonetics and Speech Sciences
    • /
    • v.3 no.3
    • /
    • pp.99-108
    • /
    • 2011
  • The perturbation parameters like jitter, shimmer, and signal-to-noise ratio (SNR) are largely estimated in the particular segment from the subjective or whole portion of the given pathological voice signal although there are many possible regions to be able to analyze the voice signals. In this paper, the pathological voice signals were classified as type 1, 2, 3, or 4 according to narrow band spectrogram and the value differences of the perturbation parameters extracted in the subjective and entire portion tended to be getting bigger as from type 1 to type 4 signals. Therefore, sample selection method based on moving window to analyze type 2 and 3 signals as well as type 1 signals is proposed. Although type 3 signals cannot be analyzed using the perturbation analysis, the type 3 signals by selecting out the samples in which error count is less than 10 through moving window were analyzed. At present, there is no method to be able to analyze the type 4 signals. Future research will endeavor to determine the best way to evaluate such voices.

  • PDF

Analysis of Microwave-Induced Thermoacoustic Signal Generation Using Computer Simulation

  • Dewantari, Aulia;Jeon, Se-Yeon;Kim, Seok;Nikitin, Konstantin;Ka, Min-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Computer simulations were conducted to demonstrate the generation of microwave-induced thermoacoustic signal. The simulations began with modelling an object with a biological tissue characteristic and irradiating it with a microwave pulse. The time-varying heating function data at every particular point on the illuminated object were obtained from absorbed electric field data from the simulation result. The thermoacoustic signal received at a point transducer at a particular distance from the object was generated by applying heating function data to the thermoacoustic equation. These simulations can be used as a foundation for understanding how thermoacoustic signal is generated and can be applied as a basis for thermoacoustic imaging simulations and experiments in future research.

Specific Cell-Signal Targets for Cancer Chemotherapy

  • Aszalos, Adorjan
    • Archives of Pharmacal Research
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • Attempts to develop drugs, specific for cancer cells, are dealt here according to the intended cell-target. While many target specific drugs were developed, they reach only moderate successes in clinics for reasons, such as, delivery problem, lack of in vivo efficacy or toxicity. However, recent efforts focusing on the diversity of tyrosine kinases, participating in cell-signal transduction, brought fruit. The first such drug, Givec, approved by the USFDA recently, is used in clinics with great success to threat CML. The drug inhibits tyrosin kinase of bcr-abl, c-abl and v-abl. Work is progressing on other tyrosin kinase inhibitors and on other type of specific cancer cell signal protein inhibitors. These efforts are hoped to yield better cures for cancer in the near future.

Implementation of BOC Signal Acquisition Using a DSP/FPGA Board

  • Chen, Yu-Hsuan;Juang, Jyh-Ching;Kao, Tsai-Ling
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.405-410
    • /
    • 2006
  • Future GNSS signal using BOC modulation brings the advantages of positioning accuracy and multipath rejection. However, the BOC signal has an ambiguous autocorrelation function that complicates the process of acquisition. Three techniques that solve the ambiguous problem are BPSK-like, Sub Carrier Phase Cancellation, and Bump Jumping. In this paper, these methods are implemented by means of a DSP/FPGA board. Moreover, an experiment is conducted to examine and compare the performance of these techniques.

  • PDF

Correlation Analysis of Electrocardiogram Signal according to Sleep Stage (수면 단계에 따른 심전도 신호의 상관관계 분석)

  • Lee, JeeEun;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.12
    • /
    • pp.1370-1378
    • /
    • 2018
  • There is a problem to measure neutral bio-signals during sleep because of inconvenience of attaching lots of sensors. In this study, we measured single electrocardiogram(ECG) signal and analyzed the correlation with sleep. After R-peak detection from ECG signal, we extracted 9 features from time and frequency domain of heart rate variability(HRV). Mean of HRV, RR intervals differing more than 50ms(NN50), and divided by the total number of all RR intervals(pNN50) have significant differences in each sleep stage. Specially, the mean HRV has an average of 87.8% accuracy in classifying sleep and awake status. In the future, the measurement ECG signal minimizes inconvenience of attaching sensors during sleep. Also, it can be substituted for the standard sleep measurement method.

Design and Implementation of Magnetostatic Surface Wave Band Pass Finer at 26GHz Range (26GHz대 정자표면파 대역통과 필터 설계 및 제작)

  • 김명수;김동영;이상석
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.397-400
    • /
    • 2000
  • Telecommunication system demands for increased bandwidths and operating frequencies for analog signal processing could be satisfied in the near future by the emergence of a novel technology based on magnetostatic waves propagating in low loss ferrimagnetic films. The magnetostatic wave is the only available technology for analog signal processing directly at millimeter wave frequencies. This paper has been studied the design and implementation of a Magnetostatic Surface Wave band-pass filter for LMDS system.

  • PDF

The Kaiser Rocket Effect in Cosmology

  • Bahr-Kalus, Benedict
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.43.3-43.3
    • /
    • 2021
  • The peculiar motion of the observer, if not (or only imperfectly) accounted for, is bound to induce a well-defined clustering signal in the distribution of galaxies. This spurious signal is related to the Kaiser rocket effect. We examined the amplitude of this effect and discuss possible implications for analysis and interpretation of future cosmological surveys. We found that it can in principle bias very significantly the inference of cosmological parameters, especially for primordial non-Gaussianity.

  • PDF