• 제목/요약/키워드: Full-scale pump

검색결과 25건 처리시간 0.027초

대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전 (Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT))

  • 안종우;김건도;김기섭;박영하
    • 대한조선학회논문집
    • /
    • 제52권6호
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

DAF 펌프를 이용한 실규모 용존공기부상 공정의 전처리 조건 (Pretreatment Condition in the Full Scale Dissolved Air Flotation Process Using a DAF Pump)

  • 이창한;안대명;김성수;조석호;안갑환
    • 대한환경공학회지
    • /
    • 제31권1호
    • /
    • pp.58-63
    • /
    • 2009
  • 용존공기부상(Dissolved Air Flotation)은 조류, 휴믹물질, 및 저밀도 입자가 포함된 원수의 처리에서 침전지보다 우수한 성능을 가지는 공정이다. 본 연구는 실험실과 실규모의 DAF 펌프형 시스템을 이용하여 정수처리공정의 전처리(응집/응결) 조건에 따른 처리효율을 비교하여 나타하였다. 실규모 DAF 펌프형 시스템(Full scale DAF pump system ; F-DAF)은 처리용량과 수력학적 부하량을 각각 5,000 톤/일과 10 m/hr이며, F-DAF는 D 정수장의 원수에서 전처리(혼화/응집) 및 운전성능을 최적화하기 위해 운전하였다. 실험실 규모의 실험결과는 원수 탁도 13.8~56.3 NTU에서 최적 PSO-M 주입량은 2.7~4.5 mL/$m^3$/NTU이었다. 이와같이 최적 응집제 주입 조건에서 유출수의 탁도를 1.0 NTU 이하로 1개월 동안 유지하며 F-DAF의 운전이 가능하였다.

액체로켓엔진용 터보펌프의 고온 성능시험 (Hot Test of a Turbopump for a Liquid Rocket Engine)

  • 홍순삼;김대진;김진선;김진한
    • 대한기계학회논문집B
    • /
    • 제33권12호
    • /
    • pp.933-938
    • /
    • 2009
  • Hot test of a full-scale turbopump for a 30-ton-thrust liquid rocket engine was carried out. The turbopump is composed of an oxidizer pump, a fuel pump, and a turbine on a single shaft. Model fluid was used in the test, that is, hot air for the turbine and water for the pumps. The turbopump was operated stably at full speed for 120 seconds. In terms of performance characteristics of pumps and turbine, the results from the turbopump assembly test are compared with those from the turbopump component tests which were performed at about half of the design rotational speed.

TFT-LCD 생산공정을 위한 실리콘 펌프 및 제어시스템에 관한 연구 (Study on the Silicon Pump and Control System for TFT-LCD Manufacturing Process)

  • 박형근
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3618-3622
    • /
    • 2012
  • 본 연구에서는 LCD 생산라인에서 장기적으로 정체상태에 있는 모듈의 수율을 높이고, 현재 TFT-LCD 생산공정에 필수적인 고압의 실리콘주입 장비 및 정밀 제어시스템을 개발하였다. 본 개발을 통하여 향후 본격생산을 준비중인 차세대 디스플레이 생산라인뿐만 아니라 중국으로 이전중인 LCD 생산 설비의 라인 환경에서 장비의 효율을 최대한 발휘함으로써 신규 투자비용을 최소화하고 최대의 효과를 창출할 수 있도록 세부 동작 시퀀스를 제어하기 위한 H/W와 S/W 시스템을 생산라인에 실장하였다. 또한, Fast-evacuating을 위한 Vacuum pump 구조를 제안하고 Pump control 회로 설계 및 실험을 통해 제품화하였다.

PIV에 의한 가정용보일러용 순환펌프의 내부 유동장 계측 (Measurement of Flow Field in a Domestic Boiler Circulation Pump by PIV)

  • 임유청;김재현;최민선;이영호
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.13-19
    • /
    • 1999
  • The purpose of the present experimental study is to apply multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to high-speed flow region within a domestic boiler circulation pump. Two different kinds of flow rate($27{\ell}/min,\;19{\ell}/min$)are selected as experimental condition. A volute casing and Impeller made of transparent Polycarbonate were made for the easy access of the illumination laser via fiber optical line and cylinder lens assembly to the measuring region. A CCD camera is syncronized with AOM to acquire clear original particle images. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous and time-mean velocity distribution, velocity profile and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a commercial circulation pump.

  • PDF

PIV에 의한 가정용 온수펌프의 유동장 계측 (Measurement of Flow Field in a Domestic Hot-Water Pump by PIV)

  • 이현;임유청;김재현;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

75톤급 액체로켓엔진용 터보펌프 조립체의 상사매질 성능시험 (Performance Test of Turbopump Assembly for 75 Ton Liquid Rocket Engine Using Model Fluid)

  • 홍순삼;김진선;김대진;김진한
    • 한국추진공학회지
    • /
    • 제15권2호
    • /
    • pp.56-61
    • /
    • 2011
  • 추력 75톤급 액체로켓엔진용 터보펌프 조립체 실물형에 대하여 정격 회전수에서 성능시험이 수행되었다. 실매질 대신 상사매질을 사용하였는데 산화제펌프에는 액체질소, 연료펌프에는 물, 터빈에는 고온 공기가 공급되었다. 시험 중 터보펌프는 안정적으로 운전되었으며 성능 요구조건을 만족시켰다. 운전 초기의 회전수 상승구간에서도 펌프의 양정계수와 유량계수는 일정하게 유지되었다. 터보펌프 단품 성능시험과 조립체 성능시험 결과를 비교할 때 펌프 양정계수와 터빈 효율이 두 종류의 성능시험에서 비교적 잘 일치하였다.

75톤급 액체로켓엔진용 터보펌프 조립체의 상사매질 성능시험 (Performance Test of Turbopump Assembly for 75 Ton Liquid Rocket Engine Using Model Fluid)

  • 홍순삼;김진선;김대진;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.27-32
    • /
    • 2010
  • 추력 75톤급 액체로켓엔진용 터보펌프 조립체 실물형에 대하여 정격 회전수에서 성능시험이 수행되었다. 실매질 대신 상사매질을 사용하였는데 산화제펌프에는 액체질소, 연료펌프에는 물, 터빈에는 고온 공기가 공급되었다. 시험 중 터보펌프는 안정적으로 운전되었으며 성능 요구조건을 만족시켰다. 운전 초기의 회전수 상승구간에서도 펌프의 양정계수와 유량계수는 일정하게 유지되었다. 터보펌프 단품성능시험과 조립체 성능시험 결과를 비교할 때 펌프 양정계수와 터빈 효율이 두 종류의 성능시험에서 비교적 잘 일치하였다.

  • PDF

수평형 지열 히트펌프 난방 성능 분석을 위한 실험적 연구 (Experimental Study for Horizontal Geothermal Heat Pump Heating Performance Analysis)

  • 임병찬;조성우
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권2호
    • /
    • pp.7-12
    • /
    • 2016
  • This study have an objective to suggest basic data and measured result of heating performance on water-water type horizontal geothermal heat pump which is based on heating and cooling load calculation result of small residential house. The average temperature during measured periods is $9.4^{\circ}C$ on primary EWT and is $7.6^{\circ}C$ on primary LWT. The temperature difference shows $1.8^{\circ}C$ as average temperature. Because the average outdoor temperature of peak is lager than on December and than on January, the temperature difference between EWT and LWT is bigger that on January than that on December. The system COP is 3.62.

현장타설형 건물 기초를 이용한 지중열 공조시스템의 성능평가에 관한 연구 (A Study on Development of a Ground-Source Heat Pump System Utilizing Cast-in-place Concrete Pile Foundation of a Building)

  • 황석호;남유진
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.641-647
    • /
    • 2010
  • Ground-source(Geothermal) heat pump(GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump(ASHP) systems. However, GSHP systems are not widespread because of their expensive installation costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a full-scale experiment. As a result, the average values for heat rejection were 186~201 W/m(per pile, 25 W/m per pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems.