• Title/Summary/Keyword: Frequency bias

Search Result 683, Processing Time 0.033 seconds

Availability Assessment of Single Frequency Multi-GNSS Real Time Positioning with the RTCM-State Space Representation Parameters (RTCM-SSR 보정요소 기반 1주파 Multi-GNSS 실시간 측위의 효용성 평가)

  • Lee, Yong-Chang;Oh, Seong-Jong
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.1
    • /
    • pp.107-123
    • /
    • 2020
  • With stabilization of the recent multi-GNSS infrastructure, and as multi-GNSS has been proven to be effective in improving the accuracy of the positioning performance in various industrial sectors. In this study, in view that SF(Single frequency) GNSS receivers are widely used due to the low costs, evaluate effectiveness of SF Real Time Point Positioning(SF-RT-PP) based on four multi-GNSS surveying methods with RTCM-SSR correction streams in static and kinematic modes, and also derive response challenges. Results of applying SSR correction streams, CNES presented good results compared to other SSR streams in 2D coordinate. Looking at the results of the SF-RT-PP surveying using SF signals from multi-GNSS, were able to identify the common cause of large deviations in the altitude components, as well as confirm the importance of signal bias correction according to combinations of different types of satellite signals and ionospheric delay compensation algorithm using undifferenced and uncombined observations. In addition, confirmed that the improvement of the infrastructure of Multi-GNSS allows SF-RT-SPP surveying with only one of the four GNSS satellites. In particular, in the case of code-based SF-RT-SPP measurements using SF signals from GPS satellites only, the difference in the application effect between broadcast ephemeris and SSR correction for satellite orbits/clocks was small, but in the case of ionospheric delay compensation, the use of SBAS correction information provided more than twice the accuracy compared to result of the Klobuchar model. With GPS and GLONASS, both the BDS and GALILEO constellations will be fully deployed in the end of 2020, and the greater benefits from the multi-GNSS integration can be expected. Specially, If RT-ionospheric correction services reflecting regional characteristics and SSR correction information reflecting atmospheric characteristics are carried out in real-time, expected that the utilization of SF-RT-PPP survey technology by multi-GNSS and various demands will be created in various industrial sectors.

A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system (산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구)

  • Kim, Kiyoung;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • The major purpose of this study is to construct an in-situ soil moisture verification network employing Frequency Domain Reflectometry (FDR) sensors for Cosmic-ray soil moisture observation system operation as well as long-term field-scale soil moisture monitoring. The test bed of Cosmic-ray and FDR verification network system was established at the Sulma Catchment, in connection with the existing instrumentations for integrated data provision of various hydrologic variables. This test bed includes one Cosmic-ray Neutron Probe (CRNP) and ten FDR stations with four different measurement depths (10 cm, 20 cm, 30 cm, and 40 cm) at each station, and has been operating since July 2018. Furthermore, to assess the reliability of the in-situ verification network, the volumetric water content data measured by FDR sensors were compared to those calculated through the core sampling method. The evaluation results of FDR sensors- measured soil moisture against sampling method during the study period indicated a reasonable agreement, with average values of $bias=-0.03m^3/m^3$ and RMSE $0.03m^3/m^3$, revealing that this FDR network is adequate to provide long-term reliable field-scale soil moisture monitoring at Sulmacheon basin. In addition, soil moisture time series observed at all FDR stations during the study period generally respond well to the rainfall events; and at some locations, the characteristics of rainfall water intercepted by canopy were also identified. The Temporal Stability Analysis (TSA) was performed for all FDR stations located within the CRNP footprint at each measurement depth to determine the representative locations for field-average soil moisture at different soil profiles of the verification network. The TSA results showed that superior performances were obtained at FDR 5 for 10 cm depth, FDR 8 for 20 cm depth, FDR2 for 30 cm depth, and FDR1 for 40 cm depth, respectively; demonstrating that those aforementioned stations can be regarded as temporal stable locations to represent field mean soil moisture measurements at their corresponding measurement depths. Although the limit on study duration has been presented, the analysis results of this study can provide useful knowledge on soil moisture variability and stability at the test bed, as well as supporting the utilization of the Cosmic-ray observation system for long-term field-scale soil moisture monitoring.

Magnetic Properties of Fe-6.0 wt%Si Alloy Dust Cores Prepared with Phosphate-coated Powders (인산염 피막처리 분말을 사용한 Fe-6.0 wt%Si 합금 압분자심의 자기적 특성)

  • Jang, D.H.;Noh, T.H.;Kim, K.Y.;Choi, G.B.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.5
    • /
    • pp.270-275
    • /
    • 2005
  • Dust cores (compressed powder cores) of $Fe-6.0wt\%Si$ alloy with a size of $35\~180\;{\mu}m$ in diameter have been prepared by phosphate coatings and annealings at $600\~900^{\circ}C$ for 1 h in nitrogen atmosphere. Further the magnetic and mechanical properties of the powder cores were investigated. As a general trends, the compressive strength and core loss decreased with the increase in annealing temperature. When annealed at $800^{\circ}C$, the compressive strength was 15 kgf, the permeability and quality factor were 74 and 26, respectively. Moreover the core loss at 50 kHz and 0.1 T induction was $750\;mW/cm^3$, and the percent permeability under the static field of 50 Oe was estimated to be about 78. In addition, the cut-off frequency in the cure representing the frequency dependence of effective permeability was measured to be around 200 kHz. These properties of the $Fe-6.0wt\%Si$ alloy dust cores could be considered to be due to the good insulation effect of iron-phosphate coats, the decrease in magnetocrystalline anisotropy and saturation magnetostriction and the increase in electric resistivity.

Safety Oimate Practice and its Affecting Variables in the Chemical Process Industry (화학공정산업에서 안전문화 이행과 영향 변수)

  • Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.127-133
    • /
    • 2006
  • The major purpose of this paper to identify safety climate practices, and to find the affecting variables that influence to the difference in the level of safety climate between plants and employees. And this paper attempted to find the interventions for improving safety climate in the chemical plants. The questionnaires were developed from literature review, especially made by HSE(Health and Safety Executive) in the UK and distributed to managers and workers. The frequency analysis was applied for identifying the level of safety climate. The affecting variables(plant size, accident occurrence, accident experience, injury experience and severity, and length of employment) are tested through analysis of variance(ANOVA). The results of frequency analysis showed that both managers and workers recorded generally high level of safety climate, and the major underlying problems are inadequate H&S procedures/rules, pressure for production, and rule breaking. According to the outcomes of ANOVA, the variable 'length of employment' is the only variable which makes the level of safety climate different. From the survey of safety climate practice, this study finds the level of safety climate and three major underlying problems in safety climate factors of the responded plants, and presents two interventions for improving safety performance. Despite of these outcomes, the applied factors are remained questionable for reflecting as the best ones for identifying safety climate in the chemical industry. In addition, the bias caused by self-report exist in the reliability of the response, and the equivalent size of respondents.

Millimeter-wave Broadband Amplifier integrating Shunt Peaking Technology with Cascode Configuration (Cascode 구조에 Shunt Peaking 기술을 접목시킨 밀리미터파 광대역 Amplifier)

  • Kwon, Hyuk-Ja;An, Dan;Lee, Mun-Kyo;Lee, Sang-Jin;Moon, Sung-Woon;Baek, Tae-Jong;Park, Hyun-Chang;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.10 s.352
    • /
    • pp.90-97
    • /
    • 2006
  • We report our research work on the millimeter-wave broadband amplifier integrating the shunt peaking technology with the cascode configuration. The millimeter-wave broadband cascode amplifier on MIMIC technology was designed and fabricated using $0.1{\mu}m\;{\Gamma}-gate$ GaAs PHEMT, CPW, and passive library. The fabricated PHEMT has shown a transconductance of 346.3 mS/mm, a current gain cut off frequency ($f_T$) of 113 GHz, and a maximum oscillation frequency ($f_{max}$) of 180 GHz. To prevent oscillation of designed cascode amplifier, a parallel resistor and capacitor were connected to drain of common-gate device. For expansion of the bandwidth and flatness of the gain, we inserted the short stub into bias circuits and the compensation transmission line between common-source device and common-gate device, and then their lengths were optimized. Also, the input and output stages were designed using the matching method to obtain the broadband characteristic. From the measurement, we could confirm to extend bandwidth and flat gain by integrating the shunt peaking technology with the cascode configuration. The cascode amplifier shows the broadband characteristic from 19 GHz to 53.5 GHz. Also, the average gain of this amplifier is about 6.5 dB over the bandwidth.

A Study on the Theory of $\frac {1}{f}$ Noise in Electronic Devies (전자소자에서의 $\frac {1}{f}$잡음에 관한 연구)

  • 송명호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.3 no.1
    • /
    • pp.18-25
    • /
    • 1978
  • The 1/f noise spectrum of short-circuited output drain current due to the Shockley-Read-Hal] recombination centers with a single lifetime in homogeneous nondegenerate MOS-field effcte transtors with n-type channel is calculated under the assumptions that the quasi-Fermi level for the carriers in each energy band can not be defined if we include the fluctuation for time varying quantities. and so 1/f noise is a majority carrier effect. Under these assumptions the derived 1/f noise in this paper show some essential features of the 1/f noise in MOS-field effect transistors. That is, it has no lowfrequency plateau and is proportionnal to the channel cross area A and to the driain bias voltage Vd and inversely proportional to the channel length L3 in MOS field effect transistors. This model can explain the discrepancy between the transition frequency of the noise spectrum from 1/f- response to 1/f2 and the frequency corresponding to the relaxation time related to the surface centers in p-n junction diodes. In this paper the results show that the functional form of noise spectrum is greatly influenced by the functional forms of the electron capture probability cn (E) and the relaxation time r (E) for scattering and the case of lattice scattering show to be responsible for the 4 noise in MOS fold effect transistors. So we canconclude that the source of 1/f noise is due to lattice scattering.

  • PDF

A Evaluation of the Maximum Power of the 94 GHz Gunn Diode Based on the Measured Oscillation Power (발진출력 측정을 통한 94 GHz Gunn Diode의 최대 전력 조사)

  • Lee, Dong-Hyun;Yeom, Kyung-Whan;Jung, Myung-Suk;Chun, Young-Hoon;Kang, Yeon-Duk;Han, Ki-Woong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.471-482
    • /
    • 2015
  • In this paper, design and implementation of the 94 GHz Gunn oscillator and the evaluation of the maximum power of the Gunn diode used in the oscillator are presented. The 94 GHz Gunn oscillator is used InP Gunn diode and designed employing a WR-10 waveguide. The designed oscillator is fabricated through machining and its performance is measured. The fabricated oscillator shows an oscillation frequency of 95 GHz, output power of 12.64 dBm, and phase noise of -92.7 dBc/Hz at 1 MHz offset frequency. To evaluation the maximum power of the InP Gunn diode used in oscillator, the oscillator structure is modified to a structure having a diaphram. The height of thick diaphram which is used in the oscillator is varied. As a result, an oscillator has several different load impedances, which makes it possible to plot $G_L-V^2$ plot at the post plane. Using the $G_L-V^2$ plot, the maximum power of used Gunn diode including post is computed to be 16.8 dBm. Furthermore using the shorted and zero bias Gunn diode, the post loss used for DC biasing can be computed. Using the two losses, The maximum power of a InP Gunn diode is computed to be 18.55 dBm at 95 GHz. This result is close to a datasheet.

Miniaturized Hairpin Tunable Filter with the Single Control Voltage (단일 제어 전원을 갖는 소형화된 헤어핀 튠어블 필터)

  • Myoung, Seong-Sik;Hong, Young-Pyo;Jang, Byung-Jun;Lee, Yong-Shik;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1126-1135
    • /
    • 2007
  • This paper presents the varactor-tuned miniaturized hairpin tunable filter with a single control voltage. The previously proposed miniaturization method is a very straight-forward method to miniaturize a parallel coupled-line filter. In this paper, the miniaturized hairpin tunable filter is proposed with the constant ratio rule of that the capacitances of the each stage always have constant ratio without any dependency to miniaturized electrical length. To show the validity of the proposed method, a 3rd order 0.5 dB ripple Chebyshev fitter with a center frequency of 900 MHz and a fractional bandwidth(FBW) of 10 % was designed and fabricated. The fabricated filter was based on CER-10 substrate of Taconic Inc. with 1SV277 varactor diode of Toshiba Inc. The center frequency of the fabricated filter can be changed from 606 MHz to 944 MHz, 338 MHz with the control voltage from 0.5 V to 4 V. The insertion loss of the proposed filter is increased with the increment of the control voltage, and the filter characteristics are well reserved expect of slight change of the bandwidth with the various control voltage.

A 3.2Gb/s Clock and Data Recovery Circuit without Reference Clock for Serial Data Communication (시리얼 데이터 통신을 위한 기준 클록이 없는 3.2Gb/s 클록 데이터 복원회로)

  • Kim, Kang-Jik;Jung, Ki-Sang;Cho, Seong-Ik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.72-77
    • /
    • 2009
  • In this paper, a 3.2Gb/s clock and data recovery (CDR) circuit for a high-speed serial data communication without the reference clock is described This CDR circuit consists of 5 parts as Phase and frequency detector(PD and FD), multi-phase Voltage Controlled-Oscillator(VCO), Charge-pumps (CP) and external Loop-Filter(KF). It is adapted the PD and FD, which incorporates a half-rate bang-bang type oversampling PD and a half-rate FD that can improve pull-in range. The VCO consists of four fully differential delay cells with rail-to-rail current bias scheme that can increase the tuning range and tuning linearity. Each delay cell has output buffers as a full-swing generator and a duty-cycle mismatch compensation. This materialized CDR can achieve wide pull-in range without an extra reference clock and it can be also reduced chip area and power consumption effectively because there is no additional Phase Locked- Loop(PLL) for generating reference clock. The CDR circuit was designed for fabrication using 0.18um 1P6M CMOS process and total chip area excepted LF is $1{\times}1mm^2$. The pk-pk jitter of recovered clock is 26ps at 3.2Gb/s input data rate and total power consumes 63mW from 1.8V supply voltage according to simulation results. According to test result, the pk-pk jitter of recovered clock is 55ps at the same input data-rate and the reliable range of input data-rate is about from 2.4Gb/s to 3.4Gb/s.

Effect of Acupuncture on Sciatica in Rat Models: Systematic Review and Meta-analysis (좌골신경통 백서모델에서 침치료의 효과: 체계적 문헌고찰 및 메타분석)

  • Yoon, Ye-Ji;Kim, Soojeon;Cho, Jae-Heung;Kim, Koh-Woon;Song, Mi-Yeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.1
    • /
    • pp.79-93
    • /
    • 2020
  • Objectives While sciatic neuropathy is one of the common symptoms which have the lifetime incidence of 13~40%, still there is no consensus about the standardized and the most effective conservative treatment. In addition, the importance of systematic review and meta-analysis of preclinical are growing as they could suggest possible effective treatment strategy for future studies. Therefore, we conducted systematic review and meta-analysis to estimate analgesic effect of acupuncture on sciatica in rat models. Methods Systematic search was conducted for all controlled comparative preclinical trials which assessed analgesic effect of acupuncture in sciatica rat models. Database of PubMed, EMBASE, Web of Science, CNKI and 6 Korean databases were used. The primary outcome was pain, which is evaluated by stimulus behavior tests in rat models. We assessed the methodological quality with Systematic Review Centre for Laboratory Animal Experimentation's risk of bias tool. RevMan 5.3 was used for meta-analysis and subgroup analysis was conducted according to treatment site, acupuncture point, treatment period and frequency used in electroacupuncture. Results 14 studies were finally included following our inclusion criteria. The data from meta-analysis indicated that the acupuncture significantly improved the result values of behavior tests for pain evaluation, compared to no-treatment control group in animal models (standardized mean difference=4.43, 95% confidence interval 3.16 to 5.69, Z=6.84, p<0.00001; χ2=68.02, p<0.00001; I2=82%). The results of subgroup analysis indicate that acupuncture treatment of unilateral site, distal acupoints, longer treatment period and applying 2/100 Hz frequency in electroacupuncture could be more effective. Conclusions Systematic review and meta-analysis of animal studies are getting important for the future clinical studies and the improvement of heatlh care. Therefore the results of the study would provide evidence and better design for the forthcoming studies.