• 제목/요약/키워드: Frequency Margin

검색결과 305건 처리시간 0.024초

An Experimental 0.8 V 256-kbit SRAM Macro with Boosted Cell Array Scheme

  • Chung, Yeon-Bae;Shim, Sang-Won
    • ETRI Journal
    • /
    • 제29권4호
    • /
    • pp.457-462
    • /
    • 2007
  • This work presents a low-voltage static random access memory (SRAM) technique based on a dual-boosted cell array. For each read/write cycle, the wordline and cell power node of selected SRAM cells are boosted into two different voltage levels. This technique enhances the read static noise margin to a sufficient level without an increase in cell size. It also improves the SRAM circuit speed due to an increase in the cell read-out current. A 0.18 ${\mu}m$ CMOS 256-kbit SRAM macro is fabricated with the proposed technique, which demonstrates 0.8 V operation with 50 MHz while consuming 65 ${\mu}W$/MHz. It also demonstrates an 87% bit error rate reduction while operating with a 43% higher clock frequency compared with that of conventional SRAM.

  • PDF

고주파 필터를 이용한 개선된 위상각 검출 방법 (Enhanced Phase Angle Detect Method Using High-pass Filter)

  • 허민호;송성근;김광헌;남해곤;박성준
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2370-2378
    • /
    • 2009
  • The enhanced phase angle estimation algorithm is essential to supply the power stably under synchronizing with grid source. In this paper, we are proposed the novel phase angle estimation algorithm and verified the validity of proposed method as simulation with PSIM and experiments. We sort the harmonics element using high-pass filter(HPF) that have the cut-off frequency below basic element and make reverse d-q transformation. So, it can be restored the harmonics element at stationary axis, and we can get the fundamental voltage element of AC grid. Proposed PLL method have a rapid responsibility and a large margin at controller design than conventional method because it have a small phase delay and a sufficient controller gain margin. And, it can reduce the error of voltage rms value and axis transformation according to robust PLL algorithm against the harmonic and phase unbalance.

초고속 원심분리 회전축계의 최적설계 (An Optimum Design of a Rotor-Bearing Spindle System for a Ultra Centrifuge)

  • 김종립;윤기찬;박종권
    • 한국정밀공학회지
    • /
    • 제15권6호
    • /
    • pp.145-152
    • /
    • 1998
  • This paper presents an optimum design of a rotor-bearing spindle system for a ultra centrifuge (80,000 RPM) supported by ball bearings with nonlinear stiffness characteristics. To obtain the nonlinear bearing stiffnesses, a ball bearing is modeled in five degrees of freedom and is analyzed quasi-statically. The dynamic behaviors of the nonlinear rotor-bearing system are analyzed by using a transfer-matrix method iteratively. For optimization. we use the cost function that simultaneously minimizes the weight of a rotor and maximizes the separation margins to yield the critical speeds as far from the operating speed as possible. Augmented Lagrange Multiplier (ALM) method is employed for the nonlinear optimization problem. The result shows that the rotor-bearing spindle system is optimized to obtain 9.5% weight reduction and 21% separation margin.

  • PDF

Some Micro-discharge Characteristics of the cells in ac-PDP

  • Son, Jin-Boo;Lee, Sung-Hyun;Lee, Dong-Hyun;Kim, Young-Dae;Cho, Jung-Soo;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.103-104
    • /
    • 2000
  • Voltage transfer curves have been used for analyzing the micro-discharge characteristics of cells in ac-PDP. This paper deals with the effect of working gas species, pressure and frequency of applied voltage on the micro-discharge characteristics. Using the mixture gases of He+Xe or He+Ne+Xe, wall voltage steeply varied compared with only He gas, and also voltage margin increased. Discharge voltage and voltage margin increased with increasing Xe percentage, and also wall voltage more steeply varied. In addition, the variation of effective wall capacitance which is significantly dependent on the discharge strength is discussed.

  • PDF

Comparison of vessel failure probabilities during PTS for Korean nuclear power plants

  • Jhung, M.J.;Choi, Y.H.;Chang, Y.S.
    • Structural Engineering and Mechanics
    • /
    • 제37권3호
    • /
    • pp.257-265
    • /
    • 2011
  • Plant-specific analyses of 5 types of domestic reactors in Korea are performed to assure the structural integrity of the reactor pressure vessel (RPV) during transients which are expected to initiate pressurized thermal shock (PTS) events. The failure probability of the RPV due to PTS is obtained by performing probabilistic fracture mechanics analysis. The through-wall cracking frequency is calculated and compared to the acceptance criterion. Considering the fluence at the end of life expected by surveillance test, the sufficient safety margin is expected for the structural integrity of all reactor pressure vessels except for the oldest one during the pressurized thermal shock events. If the flaw with aspect ratio of 1/12 is considered to eliminate the conservatism, the acceptance criteria is not exceeded for all plants until the fluence level of $8{\times}10^{19}\;n/cm^2$, generating sufficient margin beyond the design life.

전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구 (The Analysis and Compensation of DC to DC Converter with Current Mode Controller)

  • 김철진;김영태;송요창
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

Decentralized Load-Frequency Control of Interconnected Power Systems with SMES Units and Governor Dead Band using Multi-Objective Evolutionary Algorithm

  • Ganapathy, S.;Velusami, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.443-450
    • /
    • 2009
  • This paper deals with the design of decentralized controller for load-frequency control of interconnected power systems with superconducting magnetic energy storage units and Governor Dead Band Nonlinearity using Multi-Objective Evolutionary Algorithm. The superconducting magnetic energy storage unit exhibits favourable damping effects by suppressing the frequency oscillations as well as stabilizing the inter-area oscillations effectively. The proposed control strategy is mainly based on a compromise between Integral Squared Error and Maximum Stability Margin criteria. Analysis on a two-area interconnected thermal power system reveals that the proposed controller improves the dynamic performance of the system and guarantees good closed-loop stability even in the presence of nonlinearities and with parameter changes.

Small-Signal Analysis of a Differential Two-Stage Folded-Cascode CMOS Op Amp

  • Yu, Sang Dae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권6호
    • /
    • pp.768-776
    • /
    • 2014
  • Using a simplified high-frequency small-signal equivalent circuit model for BSIM3 MOSFET, the fully differential two-stage folded-cascode CMOS operational amplifier is analyzed to obtain its small-signal voltage transfer function. As a result, the expressions for dc gain, five zero frequencies, five pole frequencies, unity-gain frequency, and phase margin are derived for op amp design using design equations. Then the analysis result is verified through the comparison with Spice simulations of both a high speed op amp and a low power op amp designed for the $0.13{\mu}m$ CMOS process.

전력계통 건전성 지수 알고리즘 개발 (Development of Power System Health Algorithm)

  • 임진택;이성훈;이연찬;최재석;최홍석;주준영
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1328-1336
    • /
    • 2014
  • This paper proposes Power System Health Index(PSHI) newly. The paper describes several kind of power system health indices based on two main categories, which are adequacy and security. In adequacy, four kinds of health indices of Frequency, Voltage, Reserve(Operating Reserve Power and Frequency Regulation Reserve Power) and Overload of lines and transformers are proposed. In security, four kinds of health indices of Voltage(154kV, 345kV and 765kV), Overload of lines and transformers, Power flow constraint among areas and SPS are proposed. All indices are mapped with three domains, which are indicated as Health, Margin and Risk, defined with expert interview. While domains of health, margin and risk is defined similar with the conventional well being analysis of power system. The criterion of the domains is proposed using an interview with expert operators and practical reliability codes in Korea. The several kinds of health index functions, which are linear ratio, piecewise linear ration and reverse ratio function etc. are developed in this paper. It will be expected that the developed health indices can help operators to control power system more successfully and also prevent power system from accident as like as black out in future because operator can make a decision immediately based on more easily visual information of system conditions from too much indices acquisition of complex power system.

고주파 영차홀드의 샘플링 주기와 물리적 댐퍼가 안정적인 햅틱 상호작용에 미치는 영향 (Effect of the sampling time of high-frequency ZOH and a physical damper on stable haptic interaction)

  • 이경노
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.649-654
    • /
    • 2019
  • 가상 환경과의 안정적인 상호작용은 사용자의 안전을 위해서 뿐만 아니라 사용자의 몰입감 향상을 위해서도 반드시 필요하다. 특히 현실감 높은 가상 강체 모델을 구현하기 위해서는 가상 강체 모델인 가상 스프링 상수를 가능한 크게 설계해야 한다. 그러나 가상 스프링 상수를 크게 하면 시스템이 불안정해지므로, 가상 스프링 상수의 크기에는 제한이 있다. 단일샘플링 주기를 이용하는 기존 방법보다 가상 스프링의 안정성 영역을 크게 하기 위해서 제안된 방법이 고주파 영차홀드를 포함한 햅틱 시스템 모델이다. 본 논문에서는 고주파 영차홀드의 샘플링 주기, 햅틱 장치의 물리적 댐퍼 크기와 안정적인 가상 스프링 최댓값과의 관계를 시뮬레이션을 통해 분석한다. 물리적 댐퍼 크기가 커질수록, 고주파 영차홀드의 샘플링 주기가 짧아질수록 가상 스프링의 안정성 영역은 커진다. 그리고 제시된 방법에서 비율 N이 40보다 커지면 물리적 댐퍼크기에 따라 안정성 영역을 기존 방법보다 약 3배~8배 더 크게 만들 수 있다. 따라서 본 방법이 가상환경 속 사용자의 현실감 향상에 도움이 될 것이다.