• Title/Summary/Keyword: Free surface vortex

Search Result 116, Processing Time 0.024 seconds

Effects of Combustor-Level High Inlet Turbulence on the Endwall Flow and Heat/Mass Transfer of a High-Turning Turbine Rotor Cascade

  • Lee, Sang-Woo;Jun, Sang-Bae;Park, Byung-Kyu;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1435-1450
    • /
    • 2004
  • Experimental data are presented which describe the effects of a combustor-level high free-stream turbulence on the near-wall flow structure and heat/mass transfer on the endwall of a linear high-turning turbine rotor cascade. The end wall flow structure is visualized by employing the partial- and total-coverage oil-film technique, and heat/mass transfer rate is measured by the naphthalene sublimation method. A turbulence generator is designed to provide a highly-turbulent flow which has free-stream turbulence intensity and integral length scale of 14.7% and 80mm, respectively, at the cascade entrance. The surface flow visualizations show that the high free-stream turbulence has little effect on the attachment line, but alters the separation line noticeably. Under high free-stream turbulence, the incoming near-wall flow upstream of the adjacent separation lines collides more obliquely with the suction surface. A weaker lift-up force arising from this more oblique collision results in the narrower suction-side corner vortex area in the high turbulence case. The high free-stream turbulence enhances the heat/mass transfer in the central area of the turbine passage, but only a slight augmentation is found in the end wall regions adjacent to the leading and trailing edges. Therefore, the high free-stream turbulence makes the end wall heat load more uniform. It is also observed that the heat/mass transfers along the locus of the pressure-side leg of the leading-edge horseshoe vortex and along the suction-side corner are influenced most strongly by the high free-stream turbulence. In this study, the end wall surface is classified into seven different regions based on the local heat/mass transfer distribution, and the effects of the high free-stream turbulence on the local heat/mass transfer in each region are discussed in detail.

Visualization of Vortex-induced Mixing at the Liquid-liquid-gas 3-phase Contact Line (액체-액체-기체 3상 접촉선에서의 와류에 의한 혼합 가시화)

  • Kim, Tae-Hong;Kim, Hyoungsoo;Kim, Seungho;Kim, Ho-Young
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.21-24
    • /
    • 2012
  • Although the motion of the three-phase contact line on a solid substrate has been extensively studied thus far, the understanding of the dynamics of the contact line of liquid/liquid/gas phases is far from complete. Here we deposit a drop of isopropyl alcohol (IPA) on water and HFE-7100 whose free surfaces are exposed to air to observe the flow field around the contact line. By combining the shadowgraph and high-speed imaging techniques, we find that vortices are spontaneously generated at the contact line, which grow in size with time. The flow is attributed to the Marangoni stress that pulls a liquid of lower-surface tension toward a liquid surface having a higher surface tension. However, it is not still clear why the entrained lower-surface-tension liquid should whirl rapidly beneath the contact line. We also visualize the flow by the particle image velocimetry (PIV) to find out that the rotational velocity reaches the order of 1 mm/s near the free surface.

Heat Transfer Characteristics on Impingement Surface with Control of Axisymmetric Jet ( 2 ) - With Acoustic Excitation - (원형제트출구 전단류 조절에 따른 제트충돌면에서의 열전달 특성 ( 2 ) - 음향여기된 제트 -)

  • Hwang, Sang-Dong;Lee, Chang-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.373-381
    • /
    • 2000
  • The flow and heat transfer characteristics on the impingement surface can be controlled by the change of vortex with the acoustic excitation, because the flow characteristics of an impinging jet are affected strongly by the vortices formed at the jet exit. To investigate the effects of acoustic excitation, we measured the velocity, turbulent intensity distributions for the free jet and local heat transfer coefficients on a impingement surface. As the acoustic excitation, subharmonic frequency of excited frequency plays an important role to the control of the jet flow. If the vortex pairings are promoted by the acoustic excitation, turbulence intensity of the jet flow is increased quickly. On the other hand if the vortex pairings are suppressed, the jet flow has low turbulence intensity at the center of the jet. Therefore, the low heat transfer rates are obtained on the impingement plate for a small nozzle-to-plate distance. However, it has high heat transfer rates at a large distance between the nozzle and plate due to the increasing of potential-core length.

A study on the flow characteristics around a suction pipe of circulation water pump in thermal power plant (화력발전소 순환수펌프 흡입관 주위에서의 유동특성에 관한 연구)

  • Choi, Sung-Tyong;Ahn, Jung-Hyeon;Moon, Seung-Jae;Lee, Jae-Heon;Yoo, Ho-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.201-204
    • /
    • 2008
  • Vortex and swirl occurring in a pump suction intake sump normally reduce the performance and disturb the safe operation of the circulation water pump in thermal power plants. This paper presents a case study of one particular intake sump design via a CFD analysis and a hydraulic model testing. The physical experiments and numerical analysis were performed under two flow and three level variation conditions. The vortex patterns around the pump suction pipe have been predicted by a commercial CFD code with the k-${\varepsilon}$ model. The model tests were conducted on a 1/10 model for a practical intake sump. The location, number and general pattern of the free surface vortex and submerged vortex predicted by CFD simulation were found to be a good agreement with those observed in the model testing.

  • PDF

Numerical Flow Analysis for Anti-Vortex Device (AVD) in Oxidizer Tank (산화제 탱크의 와류방지장치 유동해석)

  • Jang, Je-Sun;Han, Sang-Yeop;Kil, Gyoung-Sub;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.168-175
    • /
    • 2010
  • During feeding oxidizer to the engine, vortices are occurred at lower dome of oxidizer tank inside by various working environments and external forces for liquid propellant feeding system of space launch vehicle. To eliminate the vortices or swirls Anti-Vortex Devices(AVD) shall be installed at inside lower oxidizer tank. Using the numerical analysis, we have confirmed the performance of AVD and analyzed the mass flow rate by feeding time and magnitudes of swirls on the free surface of oxidizer or exit surface according to the AVD number and length. Then we could derive the optimal design of the AVD number and length.

On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment (수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구)

  • Eom, Junghyun;Lee, Du Han;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.815-824
    • /
    • 2022
  • Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affect the Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then power generation is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smooth operation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the anti vortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surface to confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition, the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8, confirming the stability of the flow.

PIV Analysis of Free Surface Effects on Flow Around a Rotating Propeller with Varying Water Depth (자유표면과 수심깊이가 회전하는 프로펠러 주위 유동에 미치는 영향에 대한 PIV 해석)

  • Paik, Bu-Geun;Lee, Jung-Yeop;Lee, Sang-Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.5 s.143
    • /
    • pp.427-434
    • /
    • 2005
  • The free surface influenced the wake behind a rotating propeller and its effects were investigated experimentally in a circulating water channel with the variation of water depth. Instantaneous velocity fields were measured using two-frame PIV technique and ensemble-averaged to study the phase-averaged flow structure in the wake region. For an isolated propeller, the flow behind the propeller is affected only by the propeller rotation speed, the leading on the blades and the proximity of the propeller to the free surface. The phase-averaged mean velocity fields show that the potential wake and the viscous wake developed on the blade surfaces. The interaction between the tip vortices and the slipstream causes the oscillating trajectory of tip vortices. The presence of the free surface greatly affected the wake structure, especially for propeller immersion depth of 0.6D. At small immersion depths, the free surface modified the tip and trailing vortices and the slipstream flow structure downstream of X/D = 0.3 in the propeller wake.

Numerical Analysis of Unsteady Viscous Flow through Ship's Propulsion Mechanism of Weis-Fogh Type by Advanced Vortex Method (최신 와법에 의한 Weis-Fogh형 선박추진기구의 비정상 점성 흐름의 수치해석)

  • Ro, Ki-Deok
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1407-1412
    • /
    • 2004
  • The velocity and pressure fields of a ship's propulsion mechanism of Weis-Fogh type are studied by advanced vortex method. The wing of NACA0010 type and the channel are approximated by a finite of source and vortex panels, and the free vortices are introduced from the surface of their bodies. The viscous diffusion of fluid is represented by the core-spreading method. The velocity field is calculated on the basis of Biot-Savart law and the pressure field is calculated from the integration equation formulated by Uhlman. The flow fields of this propulsion mechanism are unsteady and complex, but the flow fields are clarified by numerical simulation.

  • PDF

An Experimental Study for the Structure of Conical Vortex at the Low-Rise Building Roof by using a PIV Technique (PIV기법을 이용한 저층 건물 지붕에서 발생되는 원추형 와의 구조에 대한 실험적 연구)

  • Ji, Ho-Seong;Jeong, Eun-Ho;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.667-672
    • /
    • 2000
  • The Characteristics of the conical vortices on the roof surface of a low-rise building has been investigated by using a PIV(Particle Image Velocimerty) technique. The scaled model of TTU building with 1:92 scaling ratio was used. The Reynolds number based on the free stream velocity and the length of the model was $1.96{\times}10^5$. When the angle of attack for the building model is $45^{\circ}$, the conical vortices are occurred symmetrically and the center of vortices are changed with respect to the angle of the approaching flow. The rotating direction of the conical vortices found to be counter-rotating. The secondary vortex motions are investigated using the instantaneous flow field data.

  • PDF