• 제목/요약/키워드: Force Transmission

검색결과 609건 처리시간 0.032초

송전케이블 삼상단락 실증시험을 통한 전자력 대책방안 연구 (The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Underground Transmission Cable)

  • 강지원;박흥석;윤종건;김양상;홍동석;장우석
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2342-2348
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, the interaction of electromagnetic force by fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

No-backlash characteristics analysis of a cycloidal ball planetary transmission under axial pre-tightening

  • Yang, Ronggang;Wang, Naige;Xiang, Jiawei
    • Structural Engineering and Mechanics
    • /
    • 제81권4호
    • /
    • pp.481-492
    • /
    • 2022
  • Cycloidal ball planetary transmission (CBPT) has many applications as precision reducer, such as precision machinery and automation drive systems etc. The traditional analytical model of CBPT cannot accurately describe the change of the normal force of meshing points, and thus cannot describe the precise transmission process of meshing pairs. In the paper, a method for deriving the normal force equation is put forward by using the non-linear relationship between force and deformation in elastic mechanics. The two-point contact analytical models of all the meshing pairs are established to obtain the micro-displacement analytical model of CBPT under axial pre-tightening. Then, the non-real-time two-point contact analytical models of all the meshing pairs are further constructed to obtain the normal force expression to determine the critical compression coefficients. Experimental investigations are performed to verify the analytical model using the critical compression coefficients.

A Far Field Solution of the Slowly Varying Drift Force on an Offshore Structure in Bichromatic Waves - Two Dimensional Problems

  • 이상무
    • 한국해양공학회지
    • /
    • 제22권2호
    • /
    • pp.7-12
    • /
    • 2008
  • A far field solution of the slowly varying force on an offshore structure by gravity ocean waves was shown as a function of the reflection and transmission of the body disturbed waves. The solution was obtained from the conservation of the momentum flux, which simply describes various wave forces, while making it unnecessary to compute complicated integration over a control surface. The solution was based on the assumption that the frequency difference of the bichromatic incident waves is small and its second order term is negligible. The final solution is expressed in term of the reflection and transmission waves, i.e. their amplitudes and phase angles. Consequently, it shows that not only the amplitudes but also the phase differences make critical contributions to the slowly varying force. In a limiting case, the slowly varying force solution gives the one of the mean drift force, which is only dependent on the reflection wave amplitude. An approximation is also suggested in a case where only the mean drift force information is available.

철탑 사각골조의 풍력 계수 산정에 관한 실험적 연구 (An Experimental Study on the Estimate of Wind Force Coefficient of Transmission Tower Rectangular Frame)

  • 신구용;임재섭;황규석;길용식
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.73-81
    • /
    • 2011
  • 골조로 구성된 철탑의 풍력계수는 구성부재의 단면형상, 충실율 등에 의해 변하며 풍향각에 의해서도 여러 가지 특성이 나타난다. 본 연구에서는 이러한 철탑골조에 대하여 충실율과 풍향각을 변화시키면서 풍동실험을 수행하여 철탑골조에 작용하는 풍력특성을 평가한다. 실험은 먼저 철탑을 구성하고 있는 부재의 특성을 파악하기 위한 기본형상 부재에 대한 실험을 수행하였다. 그리고 철탑 사각골조는 2D와 3D 형태로 기본형에 철탑부재를 추가하는 방법과, 부재크기를 증가시키는 방법으로 충실율을 변화시킨 모형을 제작하였으며, 2D 형상은 풍향각을 0도에서 90도까지, 3D 형상은 풍향각을 0도에서 45도까지 변화시키면서 풍동실험을 수행하였다. 본 연구의 결과인 철탑 사각골조의 풍력계수 특성은 향후 철탑 풍하중 설계의 기초자료로 사용될 것이다.

케이블 삼상단락 실증시험을 통한 전자력 영향 검토 (The Study of Electromagnetic Force by Three Phase Short-Circuit Test of Cable)

  • 홍동석;김해준;박성민;장우석;박흥석;장태인;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.395_396
    • /
    • 2009
  • This paper handles with effect of electromagnetic force on the cables by fault current accompanied by accident of underground transmission cable. Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper describes the effect of electromagnetic force through results of three phase short-circuit test and electromagnetic force analysis using theoretical calculations and electrical evaluation test after three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF

광 솔리톤 전송 시스템에 있어서 최대치 추적에 의한 상호 작용력 분석 (Interaction force analysis by peak value tracking in optical soliton transmission system)

  • 변승우;송재원
    • 전자공학회논문지A
    • /
    • 제33A권7호
    • /
    • pp.15-22
    • /
    • 1996
  • In the soliton transmission system for a long-length and high bit rate data transmission systme using the nonlinear/dispersive optical fibers, the improtant problem is the loss characteristics and is the limited transmission rate by interaction forces. In this paper, It is explained the reasons of moved time position for the soliton peak value due to interaction force sof adjacent solitons. And for the analysis of interaction force affection level in the losslessmedia, we define the percent parameter of error rate due to the interaction forces and propose the optimum time distance of adjacent solitons by peak value tracking methods. With the results, initial percent of error is approximately 50% when itme difference between adjacent solitons is 5 times of funddametnal soliton pulse width. And it is confirmed that maximum transmission length of th esolitons is approximately 38 times of fundamental soliton period, which the maximum allowable percoent of error is 50%.

  • PDF

지면 반력 분석을 위한 압력판 시스템 개발에 관한 연구 (A study on the development of the force-platform system for ground reaction force analysis)

  • 최혁재;이언주;김문화;장동식
    • 대한인간공학회지
    • /
    • 제14권2호
    • /
    • pp.75-85
    • /
    • 1995
  • The purpose of this study is to develop a force-platform system suitable for real situations in industry. The developed system is a 3-axis measurement type. It consists of force-transmission, force measuring circuit, and the software that analyzes the measured force. The force-transmission transmits forces to 3 axes, which has a physical structure to minimize the interference among those axes. Force measuring circuit consists of DSP (digital signal processor) for flexible disposal of change of measurement algorithm, elimination of noise and maintenance of precision. The functions of the software are the calibration which revises the measurement error occuring during data acquisition, and various analyses of forces. The result of the experiment shows that the developed system has about 1% measurement error, is stable for repeated experiments, and is not effected by temperature change.

  • PDF

형광공명에너지전이 알파카테닌 센서를 활용한 세포 부착접합부에서의 힘 전달 이미징 (Force Transmission in Cellular Adherens Junction Visualized by Engineered FRET Alpha-catenin Sensor)

  • 장윤관;서정수;석명은;김태진
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.366-372
    • /
    • 2021
  • 캐드헤린-카테닌 복합체는 세포의 부착 접합부에서 힘의 전달에 중요한 역할을 하는 것으로 생각된다. 그러나 기계적 힘 신호를 시각화 하고 감지하는 적절한 도구의 부재로, 캐드헤린-카테닌 복합체가 세포 간 접합에서 힘 전달을 조절하는 기본 메커니즘은 아직 파악하기가 어렵다. 본 연구에서는 형광공명에너지전이를 기반으로 설계된 알파카테닌 센서를 사용하여 캐드헤린에 의해 매개되는 힘 전달을 시각화 하였다. 이러한 결과는 알파카테닌이 세포-세포 접합부에서 캐드헤린 매개 기계적에너지변환(mechanotransduction) 경로의 핵심적인 힘 트랜스듀서(force transducer) 임을 보여준다. 본 연구는 향후 기계적 힘의 세포-세포 상호간의 의사소통에 미치는 영향과 생리학적/병리학적 현상과의 관계를 연구하는 데 중요한 이해를 제공할 것이라 본다.

Effects of stiffness on reflection and transmission of micropolar thermoelastic waves at the interface between an elastic and micropolar generalized thermoelastic solid

  • Kumar, Rajneesh;Sharma, Nidhi;Ram, Paras
    • Structural Engineering and Mechanics
    • /
    • 제31권2호
    • /
    • pp.117-135
    • /
    • 2009
  • The reflection and transmission of micropolar thermoelastic plane waves at the interface between an elastic solid and micropolar generalized thermoelastic solid is discussed. The interface boundary conditions obtained contain interface stiffness (normal stiffness and transverse stiffness). The expressions for the reflection and transmission coefficients which are the ratios of the amplitudes of reflected and transmitted waves to the amplitude of incident waves are obtained for normal force stiffness, transverse force stiffness and welded contact. Numerical calculations have been performed for amplitude ratios of various reflected and transmitted waves. The variations of amplitude ratios with angle of incident wave have been depicted graphically. It is found that the amplitude ratios of reflected and transmitted waves are affected by the stiffness, micropolarity and thermal distribution of the media.

Longitudinal reaction on conductors due to tornado wind load

  • Dingyu Yao;Ashraf El Damatty
    • Wind and Structures
    • /
    • 제38권4호
    • /
    • pp.325-339
    • /
    • 2024
  • The longitudinal force resulting from tornado loads on transmission line is considered a crucial factor contributing to the failure of transmission line structures during tornado events. Accurate estimation of this longitudinal force poses a challenge for structural designers. Therefore, the objective of this paper is to provide a set of charts that can be easily used to estimate the peak longitudinal forces transferred from the conductors to a tower. The critical wind field and corresponding configuration considered in this paper are previously studied and determined. The charts should account for all the conductor parameters that can affect the value of the longitudinal force. In order to achieve that, a parametric study is first conducted to assess the variation of the longitudinal forces with different conductor parameters, based on the critical tornado configuration. Results of this parametric study are used to develop the charts that can be used to calculate longitudinal forces by adopting a multi-variable line regression. The forces calculated from charts are validated by finite element analysis. An example for the usage of the charts is provided at the end of this paper.