• 제목/요약/키워드: Foamed mortar

검색결과 23건 처리시간 0.034초

온돌 바닥용 경량기포콘크리트의 흡수특성 (The Absorption Characteristics of Foamed Concrete for On-dol)

  • 이도헌;전명훈;임정수;정민철;김경덕;민승의
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.225-230
    • /
    • 2001
  • Cast-in-place foamed concrete is a high porous material placed as base the layer of mortar screeds in the panel heating system, so the quality of mortar is affected by it. Therefore, this study is aims to investigate how the absorption characteristics of foamed concrete influences on mortar screeds according to the foamed ratio-62%, 67% and 72%- and the surface treatments of foamed concrete-water and acrylic emulsion primer spray, etc. The result of this study shows that water-spray in the surface of foamed concrete has a good effects to reduce mortar cracking.

  • PDF

경량기포모르터와 합성한 경량형강 벽체의 전단 저항 (Shear Resistance of Light-gauge Steel Stud Wall infilled with light-weight foamed mortar)

  • 이상섭;배규웅
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.397-406
    • /
    • 2004
  • 본 논문은 경량형강으로 제작한 프레임에 경량기포모르터를 채운 경량합성벽체의 전단 거동에 대한 실험 결과와 전단 강도 및 강성 평가를 제시한 것이다. 경량기포모르터는 스틸하우스 벽체의 구조 성능 및 단열 성능의 향상과 마감에 대한 시공성 개선을 위해 도입되었다. 연구 결과 단열 성능에 대한 기여도는 낮으나, 경량기포모르터의 슬러리 비중이 0.8 이상인 경우 구조 성능의 향상과 마감성이 좋은 것으로 나타났다. 본 연구에서는 전단 거동에 미치는 경량기포모르터의 영향을 알아보기 위해 경량기포모르터의 비중(0.6, 0.8, 1.0, 1.2) 벽체의 스터드 배치간격(450mm, 600mm, 900mm), 마감재(경량기포모르터, OSB, 석고보드) 및 브레이싱 등을 변수로 한 14개의 경량합성벽체를 제작하였고 비교를 위해 대표적인 스틸하우스 벽체 3개를 제작하였다. 면내전단 실험결과, 경량기포모르터를 타설한 경량합성벽체가 기존의 스틸스터드 벽체에 비해 최대 내력은 1.15~5.38배, 초기강성은 1.45~13.7배 증가한 것으로 나타났다. 또한 벽체 내부의 스터드를 900mm까지 확장하여도 무리가 없는 것으로 나타났다. 그러나 이와 같은 결과는 건조수축 균열이 억제되지 않은 상태에서 나온 것으로 경량합성벽체의 내력을 향상시키기 위해서는 경량기포모르터의 초기 건조수축균열을 억제하고 스터드와 경량기포모르터 사이의 부착력을 확보하는 것이 무엇보다도 중요한 것으로 나타났다.

경량합성벽체의 전단성능 및 압축내력 평가 (Evaluations of Shear performance and Compressive strength of Light-weight hybrid panel)

  • 이동혁;이상섭;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제17권1호통권74호
    • /
    • pp.33-43
    • /
    • 2005
  • 본 논문은 스틸스터드로 구성된 골조에 경량기포모르터를 타설 양생하여 제작한 경량합성벽체의 반복가력 전단실험에 의한 에너지 소산능력과 압축내력 실험을 통한 압축성능의 평가에 대한 연구이다. 경량기포모르터의 유무, 경량기포모르터의 비중(0.6, 0.8, 1.0, 1.2), 마감재(경량기포모르터, OSB, 석고보드) 및 브레이스의 유무, 벽체의 단위(1단위-$900mm{\times}2,400mm$, 2단위-$1,800mm{\times}2,400mm$)를 변수로 하여 실시하였던 경량합성벽체의 전단내력 평가 실험 가운데 반복 실험 결과를 동일 조건의 단조 실험과 비교하였다. 또한 기존 스틸하우스벽체와 경량합성벽체의 압축내력도 실험을 통해 조사하였다. 반복가력 실험결과, 단조가력 실험체의 거동과 약간의 차이를 보이고 있으며 이는 벽체에 채운 경량기포모르터의 비중에 따른 차이라고 생각된다. 압축내력 실험결과, 기존형 실험체에 비하여 경량기포모르터를 타설한 실험체의 최대내력은 2~2.5배, 초기강성은 2~3배 정도 증가하였다.

기포 안정성 확보를 위한 경향 기포 모르타르의 점도 분석 (Viscosity analysis of lightweight foamed mortar for foam stability)

  • 이향선;손배근;전종운;한동엽
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.52-53
    • /
    • 2018
  • In this study, viscosity analysis of the lightweight foamed mortar was conducted to evaluate the foam stability. According to a series of experiment, void volume related with density of the mixture and viscosity of the mixture were infleunced by water-to-binder ratio and addition of viscosity modifying admixture (VMA). Especially, the stability of the foam inside the mortar was confirmed with adding VMA.

  • PDF

경량합성 패널의 압축성능 평가에 관한 실험적 연구 (An Experimental Study for the Evaluations of Compressive Performance of Light-Weight Hybrid Wall Panel)

  • 이상섭;박금성
    • 한국강구조학회 논문집
    • /
    • 제19권5호
    • /
    • pp.455-462
    • /
    • 2007
  • 본 논문은 스틸스터드로 구성된 골조에 경량기포 모르터를 충전하여 제작한 경량합성벽체의 압축 실험을 통한 압축 성능의 평가에 대한 연구이다. 경량기포 모르터의 비중(80, 120), 마감재(경량기포 모르터, OSB, 석고보드) 및 패널의 고정 방식을 변수로 하여 실험체를 제작 실험하였다. 선행 연구결과와 고정부를 개선시킨 경량합성 벽체의 압축성능에 대해 실험을 통해 조사한 결과, 상세개선으로 인한 경량합성패널의 압축 최대하중은 1.07배, 초기강성은 24배 이상 성능이 크게 향상되었다. 비중과 마감재가 동일한 실험체의 경우에는 최대하중은 2.7배, 초기강성은 15배 이상 압축으로 인한 성능이 크게 향상됨을 알 수 있다. 국내설계기준에 의해 계산한 최대하중값과 실험값은 비교적 잘 일치하였다.

경량기포 콘크리트를 이용한 석재패널 부착 고강도 RC 기둥의 내화 및 폭렬특성 (Properties of the Spalling and Fire Resistance on the High Strength RC Column attached with the Stone Panel Using Lightweight Foamed Concrete)

  • 이동규;백대현;김원기;조용백;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.19-22
    • /
    • 2007
  • This study discussed the prevention of the spalling and improvement of the fire resistance performance how to fill up lightweight foamed concrete on high strength RC column attached with the stone panel. The destructive spalling extremely occur caused by sudden high temperature and increased vapor pressure corresponding to falling the ston panel at all RC column, and the steel bar is exposed. The stone panel fall off about 30 minutes and spalling occur about 70 minutes on Plan RC column, fire endurance paint, and fire endurance mortar, so it can be confirmed that fire endurance paint and mortar, which is used as fire endurance material, are not effective. In the other side, it can be protected from fire about $120{\sim}140$ minutes when the lightweight foamed concrete is used as fire endurance material. For the weight loss after the fire test, plain is 33, fire endurance paint is 37%, and fire endurance mortar s 40.7%. And W/B 60%-3 is 53.4%, 60%-1.5 is 40.1%,65%-3 is 39.4%, and 65%-1.5% is 47.1. Overall, the weight loss of the plain is lower than that of the lightweight foamed concrete.

  • PDF

기포모르터의 제특성에 관한 실험적 연구-제1보 밀도와 흡수율 특성 (Experimental Studies on the Characteristics of Foaming Mortar(I)- Part 1 characteristics of bulk density and absorption rate -)

  • 성찬용
    • 한국농공학회지
    • /
    • 제30권1호
    • /
    • pp.73-80
    • /
    • 1988
  • This study was performed to obtain the basic data which can be applied to use of foaming mortars. The results obtained were Summarized as follows; 1.At the mixing ratio of 1:1, the highest bulk densities were showed by foaming mortars, respectively. But, it gradually was decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of bulk densities were increased in richer mixing ratio and more addition of foaming agent. 2.The bulk densities were decreased up to 38.8-55.9% by mix-foaming type and 9.7-23.6% by pre-foamed type than cement mortar. 3.At the mixing ratio of 1:1, the lowest absorption rates were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of absorption rates were increased in richer mixing ratio and more addition of foaming agent. 4.Absorption rates when immersed in 72hours were showed up tp 3.41-5.85 times by mix-foaming type and 1.05- 1.S5times by pre -foamed type than cement mortar, it was significantly higher at the early stage of immersed time than cement mortar. 5.The correlations between bulk density and absorption rate were highly singnificant, respectively. The multiple regression equations of bulk density and absorption rate were computed depending on a fuction of mixing ratio and addition of foaming agent. it was highly significant respectively.

  • PDF

현장 시공성 개선을 위한 롤타입 건식바닥난방시스템 개발 (A Study on the Development of Rolled Dry Floor Heating System for Improving Workability)

  • 이규동;김준호;정창호;김동우;小川慶一郞
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.177-180
    • /
    • 2012
  • Korea residential housing generally use wet floor heating system 'Ondol' which consist of insulation cushioning, lightweight foamed concrete, hot water pipe and mortar on top of reinforced concrete slab. Wet floor heating system's installation process is too complicate and difficult to supervise field for continuing assurance quality. Also, this method has a huge impact on the progress of construction because it take a long time to cure finishing mortar and lightweight foamed concrete. Therefore, it is considered a disturbance factor of reduction of construction duration for enhancing competitiveness. In this study, we conducted an experiment about the radiant heat performance and temperature difference on upper panel of rolled dry floor heating systems which is jointly developed by Kolon global and Sumisho Metalex for remodeling housing, studio apartment and the urban-life housing.

  • PDF

경량기포 모르타르를 이용한 NATM Composite 라이닝 터널 뒤채움재의 역학적 특성 평가 (An Evaluation of the Mechanical Property for the Backfilling Material of the NATM Composite Lining Tunnel using the Lightweight Foamed Mortar)

  • 마상준;최희섭;김동민;이흥수;김경덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.717-720
    • /
    • 2008
  • This paper, an evaluation of the mechanical property for the backfilling materials of the NATM Composite lining tunnel using the lightweight foamed mortar, relates to the performance of permeability, compressive strength and unit volume weight. Therefore, this study is aimed to prove the three main factor that refered to the above line for development of new tunnel method. As the result of this study, it would be confirmed that the D mix is better than other mixs a side of all tests and its relation that is for the tunnel backfilling materials.

  • PDF

평면투수 실험을 통한 기존 배수재와 고투수성 배수재의 성능 평가 (Performance Assesment of the Existing Tunnel drain and higher permeable for the In-plane Test)

  • 마상준;이흥수;최희섭;김경덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1581-1584
    • /
    • 2008
  • In this study, performance Assesment of the existing tunnel drain and higher permeable for the In-plane Test. Two separate simulation tests from geotexitile and Lightweight Foamed Mortar compare. perfomed:the one is the in-plane test and the other is the clogging phenomenon test. As a result, NATM Composite used to Ligheweight Foamed Mortar pemability 80%, more than existing tunnel drain. Also, clogging phenomenon test do low assesment more than existing tunnel drain geotextile.

  • PDF