준설매립지반 표층건조처리를 위한 트렌치 굴착시 간극수의 침투해석 (Analysis of seepage in trenching for surface desiccation of dredged soft ground)

  • 정하익;오인규;이용길;이승원;이영남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.529-536
    • /
    • 2002
  • The purpose of this paper os to present and discuss some of flow and drain observed in modelling results. Because dredged fill ground of Yul-Chon located in the south coast of Korea is very soft, this ground should be improved after operation of surface stabilization. There are surface stabilization method such as chemical stabilization, desiccation, horizontally vacuum drain, replacement, and geosynthetics. In Yul-Chon, PTM(Progressive Trenching Method) is adopted to provide the necessity condition of surface desiccation. In the case trench in the dredged soft ground is formed by PTM equipment, pore water in the ground is drained through trench. There, drain and desiccation of surface ground increase, and bearing capacity is improved. In this research, when trench in the dredged soft ground is formed by PTM equipment, permeable characteristics and drain efficiency of pore-water are analyzed using SEEP/W software package. Results show variation of total head, pressure head, flux, hydraulic gradient, and flow quantity.

  • PDF

이중 여자 방식 가동자석형 LDM의 추력 산정과 파라미터 산출 (The calculation of thrust force and determination of parameters in moving magnet type LDM with double excited)

  • 권혁인;김용;백수현;조규만;김일남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.160-163
    • /
    • 1999
  • The thrust force of moving magnet-type linear direct current motors(MM-LDM) is analyzed in this study. A moving magnet-type LDM consists of a stator and a carriage. The stator is composed of two stick shaped electro magnetics and the carriage consists of a movable permanent magnet that is located between the two electromagnets. The method for calculating the thrust force of an MM-LDM is to analyze the energy gradient which is determined by the distribution of magnetic flux. And this paper describes the development of the generalized machine theory for d.c. linear motors and its application to determine the motor parameters.

  • PDF

자연대류를 고려한 초전도 전류도입선의 최적 설계 (Optimal design of HTS current lead considering natural convection)

  • 손봉준;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.269-273
    • /
    • 2003
  • In this paper the HTS current lead for superconducting device is studied numerical method. The current lead is cooled by surrounded He gas by natural convection. To find wall heat flux, the linearization method is adopted Numerical results using natural convection cooling are compared with conventional cooling methods such as conduction cooling and vapor cooling. The results shows that the minimum heat dissipation is much smaller than conduction cooling. Also, the minimum heat dissipation is obtained for the non-zero gradient of temperature at warm end. HTS current lead operating current sharing mode is reduce heat flow to superconducting system.

  • PDF

Evaluation of the Aerodynamic Performance of A Hybrid Mesh Based Finite Volume Code

  • ZHENG, H.W.
    • International Journal of Aerospace System Engineering
    • /
    • 제2권2호
    • /
    • pp.40-43
    • /
    • 2015
  • A hybrid mesh based finite volume compressible flow code (PolySim) has been developed recently. Instead of the simple average method for the gradients of variables at each face, the volume average is applied for the calculation of the viscous flux. What is more, an improved Green Gauss method for the calculation of the gradient is also presented. These two techniques will improve both the accuracy and robustness of the code. The aerodynamic performance of this in-house cell centered code is examined by several widely-used bench-mark test cases. These cases include flows over flat plate and RAE 2822 etc. The comparisons on results between calculation and experiment are conducted. They show that the code can produce good numerical results which agree well with the corresponding experiment data.

An Open Gradient Magnetic Separator Assembled Using NdFeB Magnets for a Use of Fine Particles Remover

  • Park, Eon-Byung;Choi, Seung-Duck;Yang, Choong-Jin;Lee, Won-Sub
    • Journal of Magnetics
    • /
    • 제3권3호
    • /
    • pp.69-73
    • /
    • 1998
  • A drum type magnetic separator was designed and optimized by computer simulation. The separator consisted of rotating outer shell of drum, magnetic flux generator drum which was assembled with numbers of disk type magnet holders, and drum axis around which the magnet holders were fixed. NdFeB magnet blocks were inserted into the disks, and the disks were assembled layer by layer along the drum axis. Magnetic circuits of the separator were simulated on the basis of highest magnetic strength, least cost, and high yield of separation by using a Vector Field S/W employing the Opera-2D program. The separator proved a separation yield of 95% in removing fine iron-base particles, and installed at Hot Rolling Mill of Pohang Iron & Steel Co. In Korea.

  • PDF

Magnetopause Waves Controlling the Dynamics of Earth's Magnetosphere

  • Hwang, Kyoung-Joo
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권1호
    • /
    • pp.1-11
    • /
    • 2015
  • Earth's magnetopause separating the fast and often turbulent magnetosheath and the relatively stagnant magnetosphere provides various forms of free energy that generate low-frequency surface waves. The source mechanism of this energy includes current-driven kinetic physical processes such as magnetic reconnection on the dayside magnetopause and flux transfer events drifting along the magnetopause, and velocity shear-driven (Kelvin-Helmholtz instability) or density/pressure gradient-driven (Rayleigh-Taylor instability) magnetohydro-dynamics (MHD) instabilities. The solar wind external perturbations (impulsive transient pressure pulses or quasi-periodic dynamic pressure variations) act as seed fluctuations for the magnetopause waves and trigger ULF pulsations inside the magnetosphere via global modes or mode conversion at the magnetopause. The magnetopause waves thus play an important role in the solar wind-magnetosphere coupling, which is the key to space weather. This paper presents recent findings regarding the generation of surface waves (e.g., Kelvin-Helmholtz waves) at the Earth's magnetopause and analytic and observational studies accountable for the linking of the magnetopause waves and inner magnetospheric ULF pulsations, and the impacts of magnetopause waves on the dynamics of the magnetopause and on the inner magnetosphere.

해수면 온도분포에 대한 최대상관계수법과 역행렬법의 적용 (Application of MCC and Inverse Method for the AVHRR/SST)

  • 이태신;정종률
    • 대한원격탐사학회지
    • /
    • 제11권1호
    • /
    • pp.19-29
    • /
    • 1995
  • The surface velocities were estimated by the Maximum Cross Correlation(MCC) method and an inverse method from AVHRR/SST. In the results of MCC, discontinuous flow fields were estimated in the case that cross correlation coefficient was above 0.5 but these flow pattern disappeared when cross correlation coefficient was above 0.9. This estimation was conspicuous near SST patterns of eddies. In the results of inverse method, flow field was continuous and eddy motion was estimated definitely but the velocity was overstimated in compared with MCC result over the area of small temperature gradient. This result may be due to temperature error included in SST calculated and spatial variation of heat flux.

Drained End Shield Effects on Heat Deposition Rate Distribution in CANDU 6 Reactor End Shield Structure

  • Jin, Yung-Kwon;Kim, Kyo-Youn;Hwang, Hae-Ryong
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.570-577
    • /
    • 1994
  • The loss of water in the carbon steel balls and water region of the end shield for CANDU 6 reactor could lead to significant temperature gradient through the end shield structure which amy result in the excessive deformation. With an assumed end shield drained scenario, the heat deposition rates were calculated through the end shield associated with the central fuel channel during full power operation as an initial step to thermal stress analysis. The drained case was compared with that of water present normal case in therms of heat deposition rater and the total heating throughout the end shield regions. The compared results show that the heat deposition and the total heating remain almost the same between the two cases. It was found that the change of volume integrated flux in the end shield regions due to the loss of water contribute a negligible effect on the heat deposition in this region.

  • PDF

Determination of Individual Lanthanide Elements by Neutron Activation Using a New Comparator Technique

  • Lee, Chul;Yim, Yung-Chang;Chung, Koo-Soon
    • Nuclear Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.83-89
    • /
    • 1972
  • 중성자 선속 모니타로써 단 수명 방사성 동위원소인 $^{56}$ Mn을 이용한 새로운 비교법을 사용하여 모나자이트중에 함유된 개개 희토류원소의 함량을 중성자 방사화법으로 정량하였다. 전회토류원소를 군으로 분리하고 난 다음 중성자 조사를 하였으며 개개 희토류 원소는 양이온 교환수지통을 통하여 알파 하이드록씨 부탈산으로 구배 용출시킴으로서 분리하였다. 루데슘으로 부터 란타늄까지 14개의 희토류원소를 정량하였다.

  • PDF

Temperature change around a LNG storage predicted by a three-dimensional indirect BEM with a hybrid integration scheme

  • Shi, Jingyu;Shen, Baotang
    • Geosystem Engineering
    • /
    • 제21권6호
    • /
    • pp.309-317
    • /
    • 2018
  • We employ a three-dimensional indirect boundary element method (BEM) to simulate temperature change around an underground liquefied natural gas storage cavern. The indirect BEM (IBEM) uses fictitious heat source strength on boundary elements as basic variables which are solved from equations of boundary conditions and then used to compute the temperature change at other points in the considered problem domain. The IBEM requires evaluation of singular integration for temperature change due to heat conduction from a constant heat source on a planar (triangular) region. The singularity can be eliminated by a semi-analytical integration scheme. However, it is found that the semi-analytical integration scheme yields sharp temperature gradient for points close to vertices of triangle. This affects the accuracy of heat flux, if they are evaluated by finite difference method at these points. This difficulty can be overcome by a combination of using a direct numerical integration for these points and the semi-analytical scheme for other points distance away from the vertices. The IBEM and the hybrid integration scheme have been verified with an analytic solution and then used to the application of the underground storage.